• Title/Summary/Keyword: Electrode Configuration

Search Result 196, Processing Time 0.023 seconds

Experimental Investigation of Parametric Effects on the Void Fraction Measurement and Flow Regime Characterization by Capacitance Transducers -Part I : Stationary Test- (캐패시턴스 변환기를 이용한 기포율 측정과 유동영역결정에 미치는 각종변수의 영향에 관한 실험적연구 -제1부 : 적정실험결과-)

  • Moon-Hyun Chun;Chang-Kyung Sung
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.34-44
    • /
    • 1985
  • The main purpose of this work is to study the effects of (1) configuration, size, and materials of electrodes, (2) flow pattern, (3) electrode position with respect to a dielectric boundary on the void fraction measurement and flow regime characterization by capacitance transducers. From the experimental results, relationships between the measured relative capacitance and void fraction are obtained for both annular and stratified flow systems under static condition, and this result is compared with theoretical predictions. From this study it can be concluded that (1) the strip-type electrodes are more sensitive than ring-type electrodes for both annular and stratified flows, (2) electrode size does not affect the relative capacitance vs. (1-$\alpha$) curve, and (3) electrode position is important for stratified flows but it has no effect on annular flows.

  • PDF

A Water Model Study on Molten Metal Flow in Die Cavity of Die Casting (다이캐스트 주물의 금형공동내에서 탕류에 관한 수모델적 연구)

  • Kim, Myung-Jae;Choi, Hee-Ho;Cho, Nam-Don
    • Journal of Korea Foundry Society
    • /
    • v.14 no.6
    • /
    • pp.576-589
    • /
    • 1994
  • Water modeling experiments and computer simulation for the predictions of defects of die castings are very important to produce high quality castings with less cost. The relation between the variable air vent system and the characteristics of the fluid flow in the die cavity is studied by using water modeling tests, which give ideas on reasonable designing of die cavity, vent arrangement and gating system. In order to test the water modeling, injection is done by using water containing NaCl. Flow behaviors in cavities are visualized by high speed camera and video tape recorder, and local filling time is measured with electrode sensors. Special attention is paid to the configuration of die cavity. Simulated results by computer are examined and compared with the results of water modeling experiments. There are close correlations between the simulated results and water modeling ones.

  • PDF

A 3-D Finite Element Analysis on the Characteristics of High Power Trigatron (3차원 유한요소법을 이용한 대전력 트리가트론의 특성 해석)

  • Lee, Won-Young;Park, Jeong-Ho;Ju, Heung-Jin;Choi, Seung-Gil;Ko, Kwang-Cheol;Kang, Hyeong-Bu
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.205-207
    • /
    • 2001
  • This study is characteristic analysis to optimize triggering of a high-power trigatron by FEM which is used to analyse electric field distribution in the trigatron. Triggering characteristics of a trigatron depends on arrangement of voltage polarity applied on electrodes and configuration of electrodes. This study is the preliminary stage for an experiment and make it possible to experiment effectively by finding optimal triggering characteristics though 3-dimensional node-based FEM which can practically model the complex structured electrode system.

  • PDF

Preliminary Tests on the Characteristics of Free Jet Flow with Applying Electric Fields (교류 전기장이 인가된 층류 자유제트유동의 특성에 관한 예비 조사)

  • Kim, Gyeong Taek;Lee, Won June;Park, Jeong;Kwon, Oh Boong
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.191-194
    • /
    • 2014
  • The characteristics of laminar free jet flow with having applied AC electric fields have been investigated experimentally. A single electrode configuration was adopted such that electric fields were applied directly to nozzle and thus the surrounding could be an infinite ground. The experimental results showed that the jet flow with AC was modified significantly. At a certain axial distance, the laminar fuel stem was broken down and subsequently it was separated into three parts when AC electric fields were applied over a certain voltage in a range of frequencies less than 120 Hz. The breakdown point was measured by varying applied AC voltage and frequency. The effect of applying electric fields to jet flow was discussed in detail.

  • PDF

Preliminary Tests on Change of Free Jet Flow in Laminar with Applying Electric Fields (교류 전기장이 인가된 층류 자유제트유동의 변화에 관한 예비 조사)

  • Kim, Gyeong Taek;Lee, Won June;Park, Jeong
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.383-386
    • /
    • 2014
  • The characteristics of gas free jet flows in laminar with having applied electric fields have been investigated experimentally. A single electrode configuration was adopted such that electric fields were applied directly to nozzle and thus the surrounding could be an infinite ground. The experimental results showed that breakdown point at laminar flow has been measured by varying the applied voltage and frequency of AC. The effect of applying electric fields to free jet flow in laminar was discussed in detail.

  • PDF

Development of Desktop Dry Electrical Discharge Machining (EDM) System and Experimental Performance Evaluations (데스크톱 건성 방전가공 시스템의 개발 및 실험적 성능평가)

  • Lee, Sang-Won;Oh, Young-Seok;Ahn, Soo-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.119-124
    • /
    • 2010
  • This paper addresses the design and fabrication of desktop die-sinking dry electrical discharge machining (EDM) system and its experimental performance analysis. The developed desktop dry EDM machine has the horizontal configuration with the size of $300{\times}200{\times}260mm$. The experimental performance analysis is conducted to investigate the effects of EDM conditions and dielectric gas temperature on the surface roughness of EDMed slots and number of EDM sparks. The experimental results demonstrate that low feed rate and large electrode displacement are good for better surface roughness and more number of EDM sparks. In addition, low temperature of dielectric gas results in better surface roughness.

Liquid Crystal Device associated with Fringe-Field Driven Optically Compensated Splay

  • Jung, B.S.;Kim, S.J.;Oh, S.M.;Lee, S.H.;Kim, H.Y.;Kim, S.Y.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1197-1199
    • /
    • 2004
  • We have studied an optically compensated splay (OCS) mode driven by fringe electric field. The OCS configuration obtained by applying voltage to vertically aligned LCs shows a dark state when an optic axis of the OCS cell coincides with one of crossed polarizer axis. When the fringe electric field is applied, the LC director rotates in plane above whole electrode surface, giving rise to the high transmittance, the low operating voltage and wide viewing angle simultaneously.

  • PDF

Morphing wing using Macro Fiber Composite actuator (압전섬유작동기를 이용한 형상적응날개)

  • Na, Young-Ho;Kim, Ji-Hwan
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.9-12
    • /
    • 2005
  • Recently, research on the morphing wing is an interesting issue to develop the capability of the wing such as improving the lift and reduction of drag during the operation of an aircraft by changing the wing shape from one configuration to another. A more efficient weight reduction of the wing using smart or morphing wing concept can be achieved in comparison with the conventional flaps. In this study, it is investigated the behaviors of the morphing wing using Macro Fiber Composite (MFC) actuators. Generally, MFC is the piezocomposite actuator with the rectangular PZT fiber and epoxy matrix, and uses the interdigitated electrode to produce more powerful actuation in the in-plane direction. Furthermore, it can produce the twisting actuation as compared with the traditional PZT actuators. In the formulation, the first-order shear deformation plate theory is used, and finite element method is adopted in the numerical analysis of the model. Results show the characteristics of the static behavior of the morphing wing according to the change of the actuation voltage.

  • PDF

The Construction of Safety Measurement Equipment of Grounding Electrode for Distribution System (배전용 접지전극의 안전성 분석 장치 구성)

  • Kang, Moon-Ho;Park, Young-Keun;Jang, Sang-Ok;Won, Yoon-Chan;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.218-221
    • /
    • 2005
  • Grounding electrodes as discharge paths to the earth are normally used to ensure the safety of human body and facilities from the over-voltages in distribution power system, and each grounding mode has a prescribed ground resistance value respectively which is applied by the utilities. As the various electrodes for distribution power system are recently developing to improve the performance of them and resolve the problem of space restriction, it is necessary to measure and investigate the safety of human body of developed electrodes. Therefore, in this paper, we provide briefly a technical comparison of two standards, i.e. IEEE Std 80 and the IEC 479-1, and describe the configuration of safety measurement system which can measure the step voltage and the touch voltage of grounding electrodes based on IEEE Std 80.

  • PDF

A Study on the Partial Discharge Measurement using Antenna in Metal-Enclosed Switchgear (폐쇄형 배전반내의 안테나를 이용한 부분방전측정에 관한 연구)

  • Kim, Young-No;Lee, Young-Suk;Seo, In-Chul;Hong, Jong-Suk;Kim, Jae-Chul;Kang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.534-536
    • /
    • 2000
  • This paper describes measurement and diagnosis methods for enclosed switchboards using antenna. In the laboratory partial discharges are generated on a needle-plate electrode configuration, the detected electromagnetic wave is analyzed by FFT. The detected electromagnetic wave in real enclosed switchboards is also analyzed by FFT, which is compared with frequency spectra of the laboratory to detect the partial discharge. The relationship between the partial discharge characteristics and the electromagnetic wave has been discussed.

  • PDF