• 제목/요약/키워드: Electrode Body

검색결과 169건 처리시간 0.029초

A Study on the Development of Insulated Electrode Tip for Spot Welding to Reduce Indentation (점용접 시 압흔 깊이 감소를 위한 절연팁 개발에 관한 연구)

  • 서승일;장상길
    • Journal of Welding and Joining
    • /
    • 제21권1호
    • /
    • pp.42-47
    • /
    • 2003
  • Stainless rolling stocks are usually fabricated by spot welding process without painting. Indentation on the surface of the car body after spot welding injures the beauty of the stainless rolling stocks. In this study, insulated electrode tips to reduce the indentation are developed and applied to the actual spot welding works. The developed tips are composed of head, neck, hole for cooling water, body and resistance material. They provide large surface contact area with the base materials during spot welding and enhance the current density by necking. Experimental results using the developed tips show that small indentation and sufficient tensile shear strength is produced due to large contact area and enhanced current density.

Dynamics of a Micro Three-Axis Ring Gyroscope Considering Electrode Effects (전극 효과를 고려한 마이크로 3축 링 자이로스코프의 동역학)

  • 강태민;김창부
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.970-976
    • /
    • 2003
  • In this paper, we analyse and present electro-mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the notation of the gyroscope main body. The motions of the ring are electro-statically derived, sensed and balanced by electrodes. The equations of motion are formulated. The scheme of angular velocities sensing by force-to-rebalance method is presented. The dynamic characteristics of a ring gyroscope are calculated and compared.

  • PDF

Construction of Carbon Paste Coated Wire Ion-Selective Electrode for Chloride and Its Application to Environmental Water Analysis

  • Yong-Kyun Lee;Soo Kil Rhim;Kyu-Ja Whang
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권6호
    • /
    • pp.485-488
    • /
    • 1989
  • A carbon paste coated-wire ion-selective electrode for chloride (carbon chloride-CWE) was constructed using epoxy resin, ion-exchanger and carbon powder as a polymer membrane. Its utility, the composition of a polymer membrane, the response characteristics, and the selectivity were examined and applied to the environmental water analysis. The carbon chloride-CWE was prepared using a silver wire, which was covered with silver chloride and then coated with epoxy resin into which chloride ion-exchanger and carbon powder were previously incorporated in advance. The response of the carbon chloride-CWE was Nernstian for $1.0{\times}10^{-2}-2{\times}10^{-5}$ M chloride and the useful pH range from $10^{-2} M Cl- to 10^{-4} M Cl^-$ was 3.0-9.0. Furthermore, the selectivity of chloride over iodide, bromide, and cyanide was much improved compared with those for a solid state epoxy body chloride electrode and a liquid membrane chloride electrode. The carbon chloride-CWE was applied to determine Cl^-$ in tap and ground water. The obtained results were in good agreement with those by the established methods such as spectrophotometric or other chloride-selective electrode methods.

Design and Efficacy of Calf EMS Protective Gear for Pain Relief in PARA Taekwondo Athletes (PARA 태권도 선수의 통증 완화를 위한 종아리 EMS 보호대 설계 및 효과)

  • Kookhyun Han;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • 제28권2호
    • /
    • pp.109-124
    • /
    • 2024
  • The aim of this paper is to design and evaluate calf braces that are equipped with Electrical Muscle Stimulation (EMS) modules. These braces are intended to alleviate calf pain in PARA Taekwondo athletes. The paper also seeks to assess the effects of different textile electrode designs. PARA Taekwondo participants are at a heightened risk of injuries and pain due to the nature of this exercise, which is designed for individuals with disabilities. Additionally, there is a significant risk of strain on the lower limb muscles in PARA Taekwondo compared to regular Taekwondo. To address this issue, calf taping methods are commonly used. In this study, we develop calf EMS protective gear and aim to examine the effects of different textile electrode designs inspired by taping methods. We evaluate the differences in the effects of three different textile electrode designs through visual analog scale (VAS) and range of motion (ROM) measurements. The results show that EMS protective gear has the potential to reduce calf pain among PARA Taekwondo athletes, with electrode designs inspired by kinesiology taping providing the most effective pain relief. This research suggests that these findings may be applicable to other sports disciplines, body areas, and everyday pain relief scenarios.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • 제29권6호
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode (건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구)

  • Cho, Young Chang;Jeong, Jong Hyeong;Yun, Jeong-oh;Kim, Min Soo
    • Journal of IKEEE
    • /
    • 제23권4호
    • /
    • pp.1122-1127
    • /
    • 2019
  • In this study, the bio-impedance of the human body is able to obtain a lot of information by monitoring the pathological and physiological conditions of clinical and biological tissues. The four electrode method system for biometrics measured the potential difference between two electrodes and the other two electrodes were used as electrodes for current flow. The newly developed dry gold electrode measured impedance from 1 Hz to 50 kHz and produced reproducible results. To verify the impedance measurement of the dry electrode, the pitting was performed using an equivalent circuit model of the bioelectrode skin, and the effectiveness was demonstrated through modeling. Fixed electrode types have a constant position of the electrodes attached during the measurement, so that a stable measurement can be obtained, thereby minimizing the error.

A Study on the Development of a Novel Pressure Sensor based on Nano Carbon Piezoresistive Composite by Using 3D Printing (3D 프린팅을 활용한 탄소 나노 튜브 전왜성 복합소재 기반 압력 센서 개발 연구)

  • Kim, Sung Yong;Kang, Inpil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제41권3호
    • /
    • pp.187-192
    • /
    • 2017
  • This paper presents an ongoing study to develop a novel pressure sensor by means of a Nano Carbon Piezoresistive Composite (NCPC). The sensor was fabricated using the 3D printing process. We designed a miniaturized cantilever-type sensor electrode to improve the pressure sensing performance and utilized a 3D printer to build a small-sized body. The sensor electrode was made of 2 wt% MWCNT/epoxy piezoresistive nano-composite, and the sensor body was encapsulated with a pipe plug cap for easy installation to any pressure system. The piezoresistivity responses of the sensor were converted into stable voltage outputs by using a signal processing system, which is similar to a conventional foil strain gauge. We evaluated the pressure-sensing performances using a pressure calibrator in the lab environment. The 3D-printed cantilever electrode pressure sensor showed linear voltage outputs of up to 16,500 KPa, which is a 200% improvement in the pressure sensing range when compared with the bulk-type electrode used in our previous work.

A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility (침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • 제17권3호
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

A Finite-element Method of a Multilayer Piezoelectric Body for an Actuator Depending on Inner Electrode Pattern (내부전극패턴 변경에 따른 적층형 압전 액추에이터의 유한요소해석)

  • Lee, Hyeung-Gyu;Kang, Hyung-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제18권12호
    • /
    • pp.1124-1128
    • /
    • 2005
  • New piezoelectric actuator design, which can reduce the number of the stacking layer without lowering the piezoelectric displacement, is suggested in this work. Each layer of the new designed multilayer actuator has the same electrode pattern as the cross-sectioned layer of the existing multilayer actuator has. The piezoelectric displacement was calculated by Finite-Element Method (FEM) analysis. The maximum piezoelectric displacement of the new-designed actuator with 13 layers was calculated to be almost same value (55.9 ${\mu}m$) as that of the existing actuator with 25 layers(60.1 ${\mu}m$).

Relative Measurement of Differential Electrode Impedance for Home Healthcare Device (Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정)

  • Woo, Y.J.;Yoo, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.469-470
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

  • PDF