• Title/Summary/Keyword: Electrochemical Polarization Method

Search Result 166, Processing Time 0.025 seconds

The Evaluation of 2-25Cr-lMo Steels Degradation by the Electrochemical Polarization Method (전기화학적 분극특성을 이용한 2.25Cr-lMo 강의 열화도 평가)

  • 김지수;현양기;이재도;오세규
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.314-319
    • /
    • 2001
  • Most parts of facilities in domestic petroleum plants and power plants are needed to be abandoned, repaired or replaced, because in Korea they were built in the 1960s and, they have been used under severe conditions and exposed corrosive environments. 2.25Cr- lMo steels have excellent high-temperature mechanical properties. Therefore, the material have been widely used as heat exchanger tubes, boiler headers and its tubes in such industries. But, those microstructural evolutions in high temperature such as precipitation and carbide coarsening give a reason to degrade the material. Especially, in case of this material, carbides induced embrittlement(CIE) is the primary reason for degrading mechanical properties at over 50$0^{\circ}C$. In this paper, we introduce a electrochemical polarization method for detecting CIE quantitatively.

  • PDF

Micro Electrochemical Machining using Anodic Polarization Curve (양극분극곡선을 미용한 미세 전해가공)

  • 최영수;강성일;전종업;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.999-1002
    • /
    • 2002
  • In this research, the mechanism of micro-ECM was investigated with potentiodynamic method and the optimal condition for micro-ECM was selected by voltage-current-time curve with potentiostatic method. From the experimental result. it was confirmed that anodic voltage curve could be used very effectively for determining the optimal condition of micro-ECM, and the micro part which has extremely fine surface could be fabricated by use of micro-ECM with point electrode method.

  • PDF

Evaluation of High Temperature Material Degradation for 12Cr Steel by Electrochemical Polarization Method (전기화학적 분극법을 이용한 12Cr강의 고온 재질열화도 평가)

  • Seo Hyon-Uk;Park Kee-Sung;Yoon Kee-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.8 s.251
    • /
    • pp.965-975
    • /
    • 2006
  • High pressure turbine blades are one of the key components in fossil power plants operated at high temperature. The blade is usually made of 12Cr steel and its operating temperature is above $500^{\circ}C$. Long term service at this temperature causes material degradation accompanied by changes in microstructures and mechanical properties such as strength and toughness. Quantitative assessment of reduction of strength and toughness due to high temperature material degradation is required for residual life assessment of the blade components. Nondestructive technique is preferred. So far most of the research of this kind was conducted with low alloy steels such as carbon steel, 1.25Cr0.5Mo steel or 2.25Cr1Mo steel. High alloy steel was not investigated. In this study one of the high Cr steel, 12Cr steel, was selected for high temperature material degradation. Electrochemical polarization method was employed to measure degradation. Strength reduction of the 12Cr steel was represented by hardness and toughness reduction was represented by change of transition temperature, FATT. Empirical relationships between the electrochemical polarization parameter and significance of material degradation were established. These relationship can be used for assessing the strength and toughness on the aged high pressure blade components indirectly by using the electrochemical method.

Intepretation of Faradaic Impedance for Corrosion Monitoring

  • Itagaki, M.;Taya, A.;Imamura, M.;Saruwatari, R.;Watanabe, K.
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • A polarization resistance is generally used to estimate the corrosion rate in the corrosion monitoring by an electrochemical impedance method. When the Faradaic impedance has a time constant due to the reaction intermediate, the electrochemical impedance describes more than one loop on the complex plane. For example, the electrochemical impedance of iron in acidic solution shows capacitive and inductive loops on the complex plane. In this case, the charge transfer resistance and the polarization resistance are determined at middle and low frequency ranges, respectively. Which should be selected for corrosion resistance in corrosion monitoring, the charge transfer resistance or the polarization resistance'? In the present paper, the above-mentioned question is examined theoretically and experimentally.

Effects of the Polarization Resistance on Cyclic Voltammograms for an Electrochemical-Chemical Reaction

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.146-151
    • /
    • 2015
  • Here I report an electrochemical simulation work that compares voltammetric current and resistance of a complex electrochemical reaction over a potential scan. For this work, the finite element method is employed which are frequently used for voltammetry but rarely for impedance spectroscopy. Specifically, this method is used for simulation of a complex reaction where a heterogeneous faradaic reaction is followed by a homogeneous chemical reaction. By tracing the current and its polarization resistance, I learn that their relationship can be explained in terms of rate constants of charge transfer and chemical change. An unexpected observation is that even though the resistance is increased by the rate of the following chemical reaction, the current can be increased due to the potential shift of the resistance made by the proceeding faradaic reaction. This report envisions a possibility of the FEM-based resistance simulation to be applied to understand a complex electrochemical reaction. Until now, resistance simulations are mostly based on equivalent circuits or complete mathematical equations and have limitations to find proper models. However, this method is based on the first-principles, and is expected to be complementary to the other simulation methods.

Optical Interferometry as Electrochemical Emission Spectroscopy of Metallic alloys in Aqueous Solutions

  • Habib, K.;AI-Mazeedi, H.
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.277-282
    • /
    • 2003
  • Holographic interferometry, an electromagnetic method, was used to study corrosion of carbon steel, aluminum and copper nickel alloys in NaOH, KCI and $H_2SO_4$ solutions respectively. The technique, called electrochemical emission spectroscopy, consisted of in-situ monitoring of changes in the number of fringe evolutions during the corrosion process. It allowed a detailed picture of anodic dissolution rate changes of alloys. The results were compared to common corrosion measurement methods such as linear polarization resistance measurements and electrochemical impedance spectroscopy. A good agreement between both data was found, thus indicating that holographic interferometry can be a very powerful technique for in-situ corrosion monitoring.

Corrosion Evaluation of Epoxy-Coated Bars by Electrochemical Impedance Spectroscopy

  • Choi, Oan-Chul;Park, Young-Su;Ryu, Hyung-Yun
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.99-105
    • /
    • 2008
  • Southern exposure test specimens were used to evaluate corrosion performance of epoxy-coated reinforcing bars in chloride contaminated concrete by electrochemical impedance spectroscopy method. The test specimens with conventional bars, epoxy-coated bars and corrosion inhibitors were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. The polarization resistance obtained from the Nyquist plot was the key parameter to characterize the degree of reinforcement corrosion. The impedance spectra of specimens with epoxy-coated bars are mainly governed by the arc of the interfacial film and the resistance against the charge transfer through the coating is an order of magnitude higher than that of the reference steel bars. Test results show good performance of epoxy-coated bars, although the coatings had holes simulating partial damage, and the effectiveness of corrosion-inhibiting additives. The corrosion rate obtained from the impedance spectroscopy method is equivalent to those determined by the linear polarization method for estimating the rate of corrosion of reinforcing steel in concrete structures.

A study on the evaluation for material degradation of 0.0Cr-0.5Mo steel by a electrochemical polarization method (전기화학적 분극법에 의한 1.0Cr-0.5Mo강의 경년열화 평가에 관한 연구)

  • Na, Eui-Gyun;Kim, Hoon;Lee, Jong-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.177-189
    • /
    • 1998
  • The contents of this paper include a non-destructive technique for evaluating the degradation of the boiler superheater tube in a fossil power plant through an electrochemical polarization test. Correlation between Ip of polarization parameter and SP-DBTT for the superheater tubes in long-term use was obtained. 1.0Cr-0.5Mo steel was degraded by softening, and the degree of degradation was dependent upon carbides with Cr and Mo elements. Since brittle fracture at low temperature and ductile fracture mode at high temperature were shown, similarity between standard Charpy and small punch tests could be found. In addition, SP-DBTT showing the degree of degradation was higher, as the time-in use of the materials got longer. Electrolyte including picric acid of 1.3 g in distilled water of 100ml at 25.deg. C temperature and sodium tridecylbenzene sulfonate with 1g could be applied to evaluate the degradation of 1.0Cr-0.5Mo steel by means of the electrochemical polarization test. Ip and Ipa values measured through the electrochemical test are the appropriate parameters for representing the degradation of the superheater tube(1.0Cr-0.5Mo steel) for the fossil power plant. It is poassible to evaluate the degradation of materials with different time histories electrochemically, by Ip value only, at field test.

Crevice Corrosion Evaluation of Cold Sprayed Copper (저온분사코팅구리의 틈새부식 특성 평가)

  • Lee, Min-Soo;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.247-260
    • /
    • 2010
  • The developement of a HLW disposal canister is under way in KAERI using Cold Spray Coating technique. To estimate corrosion behavior of a cold sprayed copper, a creivice corrosion test was conducted at Southwest Research Institute(SWRI) in the United State. For the measurement of repassivation potential needed for crevice corrosion, three methods such as (1) ASTM G61-86 : Cyclic Potentiodynamic Polarization Measurements, (2) Potentiodynamic Polarization plus intermediate Potentiostatic Hold method, and (3) ASTM G192-08 (THE method) : Potentiodynamic- Galvanostatic-Potentiostatic Method, were introduced in this report. In the crevice corrosion test, the occurrence of corrosion at crevice area was optically determined and the repassivation potentials were checked for three kind of copper specimens in a simulated KURT underground water, using a crevice former dictated in ASTM G61-86. The applied electrochemical test techniques were cyclic polarization, potentiostatic polarization, and electrochemical impedance spectroscopy. As a result of crevice corrosion tests, every copper specimens including cold sprayed one did not show any corrosion figure on crevice areas. And the open-cell voltage, at which corrosion reaction initiates, was influenced by the purity of copper, but not their manufacturing method in this experiment. Therefore, it was convinced that there is no crevice corrosion for the cold sprayed copper in KURT underground environment.

A study on the application of electrochemical method for degradation evaluation (열화평가에 전기화학적 방법의 응용에 관한 연구)

  • Kwon, Jae-Do;Moon, Yun-Bae;Kim, Sang-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.44-51
    • /
    • 1998
  • In order to develop the evaluation methods of degradation for the Ni-Cr-Mo-V steel, which is in use for turbine rotor in nuclear power plant, the degraded materials were prepared by simulated degradation methods. The result of impact test and fatigue crack growth test shows that the FATT(Fracture Appearance Transition Temperature) and fatigue crack growth rate increased with the increase of degradation. And the result of new electrochemical polarization test method was suggested for the evaluating FATT, fatigue crack growth exponent and coefficient C values based on the results of relationship between corrosion current density(Icorr) & FATT, and the m & C and Icorr.