• Title/Summary/Keyword: Electrochemical Migration

Search Result 64, Processing Time 0.02 seconds

Ion Migration in Metal Halide Perovskites

  • Nur'aini, Anafi;Lee, Seokwon;Oh, Ilwhan
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.71-77
    • /
    • 2022
  • Metal halide perovskites are promising photovoltaic materials, but they still have some issues that need to be solved. Hysteresis is a phenomenon that strongly is correlated with ion migration; thus, a fast, easy, and low-temperature method for measuring ion migration is required. Through selective blocking, ion migration can be measured separately, apart from electron migration. In this study, ion migration in metal halide perovskites was measured using a vertical device. At different temperatures, ionic activation energies were obtained for a range of perovskite compositions such as MAPbI3, FAPbI3, CsPbI3, and MAPbBr3. By comparing the measured ionic activation energies with the theoretical values, we conclude that among other possibilities, I- is the migrating ion in MAPbI3, FAPbI3, CsPbI3, and Br- is the migrating in MAPbBr3.

A Study on Development of Flux to Restrict Occurrence of ion Migration in Lead-Free Solder (무연솔더 내 마이그레이션 플럭스개발에 관한 연구)

  • Ryu Dong Su;Lim Jae Hoon;Woo Seong Woo
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.385-392
    • /
    • 2005
  • The restriction of the use of hazardous substances in electrical and electronic equipment legislation mandates the substitution of lead and other hazardous substances in electronics products by July 2006. Due to this legislative pressure, the electronics industry is moving to adoption of lead free solders. In this paper, we investigated a flux to restrict generating electrochemical migration in lead-free solder. The lead-free solders used in this study were Sn-0.7Cu-0.01P and Sn-3.0Ag-0.5Cu. To measure the resistance of electrochemical migration, the dew-cycle test and water drop test were adopted. As the result, now flux having high durable of electrochemical migration was developed.

  • PDF

Electrochemical Ion Migration Sensitivity of Printed Circuit Board Plated with Sn-3.0Ag-0.5Cu and Sn-37Pb (Sn-3.0Ag-0.5Cu, Sn-37Pb 표면처리 기판의 전기화학적 이온 마이그레이션 민감도)

  • Hong, Won-Sik;Park, No-Chang;O, Cheol-Min;Kim, Gwang-Bae
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.136-138
    • /
    • 2006
  • Recently a lots of problems have observed in high densified and high integrated electronic components. One of them is ion migration phenomena, which induce the electrical short of electrical circuit. Ion migration phenomena has been observed in the field of exposing the specific environment and using for a long time. Also as the RoHS restriction was started in July 1st, 2006, Pb-free solder was utilized in electronics assemblies. In this case, it is very important to compatible between components and printed circuit board(PCB), thus surface treatment materials of PCB was changed to Sn, Sn-3.0Ag-0.5Cu, Cu. Therefore these new application become to need to reevaluate the sensitivity about electrochemical ion migration. This study was evaluated the occurrence time of electrochemical ion migration using by water drop test. We utilized PCB(printed circuit board) having a comb pattern as follows 0.1, 0.318, 0.5, 1.0 mm pattern distance. Sn-3.0Ag-0.5Cu and Sn-37Pb were electroplated on the comb pattern. 6.5V and 15.0V were applied in the comb pattern and then we measured the electrical short time causing by occurring the ion migration. In these results, we evaluate the sensitivity and derived the prediction models of ion migration occurrence time depending on the pattern materials, applied voltage and pattern spacing of PCB conductor.

  • PDF

Difference of Potential Range Formed at the Anode Between Water Drop Test and Temperature Humidity Bias Test to Evaluate Electrochemical Migration of Solders for Printed Circuit Board

  • Young Ran Yoo;Young Sik Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.153-163
    • /
    • 2023
  • Two types of accelerated tests, Water Drop Test (WDT) and Temperature-Humidity-Bias Test (THBT), can be used to evaluate the susceptibility to electrochemical migration (ECM). In the WDT, liquid water is directly applied to a specimen, typically a patterned conductor like a printed circuit board. Time to failure in the WDT typically ranges from several seconds to several minutes. On the other hand, the THBT is conducted under elevated temperature and humidity conditions, allowing for assessment of design and life cycle factors on ECM. THBT is widely recognized as a more suitable method for reliability testing than WDT. In both test methods, localized corrosion can be observed on the anode. Composition of dendrites formed during the WDT is similar to that formed during THBT. However, there is a lack of correlation between the time to failure obtained from WDT and that obtained from THBT. In this study, we investigated the relationship between electrochemical parameters and time to failure obtained from both WDT and THBT. Differences in time to failure can be attributed to actual anode potential obtained in the two tests.

Ion Migration in Organic Metal Halide Perovskites (유기 금속 할라이드 페로브스카이트에서 이온 이동)

  • Oh, Ilwhan
    • Journal of the Korean Electrochemical Society
    • /
    • v.21 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • In this review, recent researches on ion transport phenomena in organic metal halide perovskite materials, which have been popular all over the world, are summarized. Although different results have been reported depending on the perovskite material composition and applied voltage, iodide seems to migrate under actual solar cell operating conditions, and occasionally methylammonium migration is observed. Perovskite is a so-called mixed conductor in which electrons and ions move simultaneously at room temperature, which greatly influences the hysteresis of the perovskite solar cell current-voltage curve and the performance degradation due to long-term operation.

Electrochemical Acceletated Test for Evaluation of Chloride Diffusion in Concrete (콘크리트 중의 염화물 확산평가를 위한 전기화학적 촉진시험법)

  • 문한영;김홍삼;이승태;정호섭;최두선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.409-412
    • /
    • 2000
  • Many researchers have been trying to evaluate the diffusion coefficient of chloride ion in concrete by using qualitative and quantitative electro-migration tests. Up to now, however, there has been no sufficient method to closely determine the diffusion coefficient of chloride ion through electro-migration test. In this paper, the diffusion coefficient of chloride ion in concrete was investigated through an electro-migration test, that is, AASHTO T 277, Dhir's method, Tang's method and Andrade's method. And the results of these test were compared with each other.

  • PDF

Prediction of ions migration behavior in mortar under 2-D ALMT application to inhibit ASR

  • Liu, Chih-Chien;Kuo, Wen-Ten
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.263-277
    • /
    • 2014
  • This study investigated four electric field configurations of two-dimensional accelerate lithium migration technique (ALMT), including line-to-line, plane-to-line, contour-to-line and plane-to-plane, and analyzed the ion migration behavior and efficiency. It was found that the free ion distribution diagram and voltage distribution diagram were similar, and ions migrated in the power line direction. The electrode modules were used for the mortar specimen with w/c ratio of 0.5. The effectively processed areas accounted for 14.1%, 39.0%, 49.4% and 51.4% of total area respectively on Day 28. Larger electrode area was more advantageous to ion migration. In addition, it was proved that the two-dimensional electric field could be divided into different equifield line active regions, and regarded as affected by one-dimensional electric field, and the ion migration results in various equifield line active regions were predicted by using the duration analysis method based on the theoretical model of ion migration obtained from one-dimensional test.

Equifield line simulation and ion migration prediction for concrete under 2-D electric field

  • Liu, Chih-Chien;Kuo, Wen-Ten;Huang, Chun-Yao
    • Computers and Concrete
    • /
    • v.12 no.4
    • /
    • pp.431-442
    • /
    • 2013
  • This study attempted to find a proper method applicable to simulating practical equifield lines of two-dimensional Accelerate Lithium Migration Technique (ALMT), and evaluate the feasibility of using the theoretical ion migration model of one-dimensional ALMT to predict the ion migration behavior of two-dimensional ALMT. The result showed that the electrolyte or carbon plate can be used as matrix to draw equifield line graph similar to that by using mortar as matrix. Using electrolyte electrode module for simulation has advantages of simple production, easy measurement, rapidness, and economy. The electrolyte module can be used to simulate the equifield line distribution diagram in practical two-dimensional electrode configuration firstly. Then, several equifield line zones were marked, and several subzones under one-dimensional ALMT were separated from various equifield line zones. The theoretical free content distribution of alkali in concrete under two-dimensional electric field effect could be obtained from duration analysis.