• 제목/요약/키워드: Electro-mechanical system

검색결과 700건 처리시간 0.044초

직접구동 영구자석 풍력발전기 기술동향 (A Technical Trends of Direct-Driven Permanent Magnet Generator for Wind Turbine)

  • 이정일;권중록;김기찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.97-100
    • /
    • 2003
  • Recently, the generators for wind turbine have been manufactured with high output power such like MW class machine in order to reduce the generation cost and to increase the energy efficiency. At the same time, direct-driven generators for wind turbine have been developed and researched, which have easy maintenance and high efficiency by simplification the system through the removal of the gear box. In this paper, at first, the advantage and disadvantage between the direct-driven generator system and conventional indirect-driven system are compared. And secondly, the permanent magnet generator (PMG) for wind turbine has been rapidly improved to cope with the recent trend which requires the high power output Per one machine and the convenience for maintenance, and the PMG is adequate for direct driven system and suitable for high-efficiency and light weight. So, the characteristics and technical trend of the PMG for wind turbine is examined. At last, a suitable technical trend for development of the permanent magnet generator for wind turbine is proposed.

  • PDF

154kV 저소음 변압기 개발 (Development of 154kV low-noise transformer)

  • 박상욱;우재희;김유현;최명준;이장우;구교선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.83-84
    • /
    • 2007
  • 본 논문은 변압기 소음저감을 위하여 Active part와 외함 형상변경에 따른 연구를 수행하였다. Active part는 변압기 소음의 주 원인인 철심의 적층방법 및 적층 step수에 대해 분석하였으며, 외함의 형상을 원형으로 변경하고 충격시험 및 유한요소 해석을 통해 원형외함의 특성을 파악하였다.

  • PDF

13.2kV/630A급 고온초전도 한류코일 개발 (Development of 13.2kV/630A High-Tc Superconducting Fault Current Limiting Coil)

  • 이찬주;강형구;남관우;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.943-944
    • /
    • 2007
  • In this paper, the development and the test of 13.2kV/630A high-Tc superconducting fault current limiting coil are described. The fault current limiting coil made of Coated Conductor (CC) was fabricated with bifilar winding method for non-inductive characteristics and tested in the distribution power system level in Dec. 2006. In order to determine the length of the superconducting coil, applied voltage per unit length(V/m) was studied analytically and it was verified through experiments. For the volume minimization, the coil was designed with concentrical arrangement method. The short-circuit test was performed with the prospective fault current of asymmetrical 10kA whose maximum fault current was $30kA_{peak}$. In the test, the voltage drop and the current of the coil were measured and the resistance of the coil was obtained. Also, the temperature rise of the coil was calculated with the relationship between the resistance and the temperature of CC. In this paper, the experimental results are analyzed and compared with the simulation.

  • PDF

구조 접합부의 손상검색을 위한 하이브리드 모니터링 (Hybrid Monitoring for Damage Detection in Structural Joints)

  • 김정태;나원배;이병준;홍동수;도한성
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.225-231
    • /
    • 2006
  • The purpose of this study is to develop a promising hybrid structural health monitoring system for structural joints. For this propose, the combined use of vibration-based techniques and electro-mechanical impedance technique is employed. For the verification of the proposed health monitoring scheme, a series of damage scenarios are designed to simulate various situations at which the connection joints can experience during their service life. The obtained experimental results, modal parameters and electro-magnetic impedance signatures, are carefully analyzed to recognize the connecting states and the target damage locations. From the analysis. it is shown that the proposed hybrid health monitoring system is successful for acquiring global and local damage information on the structural joints.

  • PDF

초정밀 자기연마 가공 기술과 최근 연구 (Magnetic Abrasive Polishing and Its Application)

  • 곽태수;곽재섭
    • 한국정밀공학회지
    • /
    • 제29권3호
    • /
    • pp.266-272
    • /
    • 2012
  • This paper has aims to share fundamental knowledge for magnetic abrasive polishing and to mainly introduce recent research results. In order to enhance a magnetic flux density for nonferrous materials, advanced magnetic abrasive polishing system which is called 2nd generation system was established by electro-magnet array table, and the effectiveness of the electromagnet array table was evaluated in real polishing experiments. To increase adhesiveness of the abrasives in high speed polishing, a silicone gel agent was proposed and carbon nanotube particles as new magnetic abrasives were applied in the magnetic abrasive polishing. In addition, a strategy for optimal step-over determination by heuristic algorithm was introduced for applying large size workpiece. Curved surfaces having a uniform radius were simulated and tested with installed electro-magnet array table.

프리스트레스트 콘크리트 거더교의 하이브리드 손상 검색 (Hybrid Damage Detection in Prestressed Concrete Girder Bridges)

  • 홍동수;이정미;나원배;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.669-674
    • /
    • 2007
  • To develop a promising hybrid structural health monitoring (SHM) system, a combined use of structural vibration and electro-mechanical (EM) impedance is proposed. The hybrid SHM system is designed to use vibration characteristics as global index and EM impedance as local index. The proposed health monitoring scheme is implemented into prestressed concrete (PSC) girder bridges for which a series of damage scenarios are designed to simulate various prestress-loss situations at which the target bridges car experience during their service life. The measured experimental results, modal parameters and electro-magnetic impedance signatures, are carefully analyzed to recognize the occurrence of damage and furthermore to indicate its location.

  • PDF

Microelectromechnical system 소자 제작을 위한 유기금속분해법에 의한 압전성 PZT(53/47)박막의 증착 (Deposition of Piezoelectric PZT(53/47) Film by Metalorganic Decomposition for Micro electro mechanical Device)

  • 윤영수;정형진;신영화
    • 한국전기전자재료학회논문지
    • /
    • 제11권6호
    • /
    • pp.458-464
    • /
    • 1998
  • This paper gives characterization of substrate and PZT(53/47) thin film deposited by metalorganic decomposition, which is concerned in deposition process and device fabrication process, to fabricate micro electro mechanical system (MEMS) device with piezoelectric material. The PZT thin films deposited by MOD at 700^{\circ}C$ for 30 minutes had a polycrystallinity, that is, no substrate dependence, while different interface were developed depending on the bottom electrodes. Such a structural variation could influence on not only the properties of the PZT film but also etching process for fabricating MEMS devices. Therefore the electrode structure is a very important factor in the deposition of the PZT film during etching process by HF acid for MEMS device with piezoelectric material. Piezoelectric coefficients of the PZT films on the different substrates were 40 and 80 pm/V at an applied voltage of 4V. Based in these results, it was possible for deposition of the PZT film by MOD to apply MEMS device fabrication process based on piezoelectricity after selection of proper bottom electrode.

  • PDF

근사적 모델 역변환을 활용한 전기-유압 액추에이터의 적응 위치 제어기 설계 (Adaptive Position Controller Design of Electro-hydraulic Actuator Using Approximate Model Inversion)

  • 이경하;백승국;구자춘
    • 로봇학회논문지
    • /
    • 제11권2호
    • /
    • pp.92-99
    • /
    • 2016
  • An electro-hydraulic actuator (EHA) is widely used in industrial motion systems and the increasing bandwidth of EHA position control is important issue. The model-inverse feedforward controller is known to extend the bandwidth of system. When the system has non-minimum phase (NMP) zeros, direct model inversion makes system unstable. To overcome this problem, an approximate model-inverse method is used. A representative approximate model inversion method is zero phase error tracking control (ZPETC). However, if zeros locate right half plane of z-plane, the approximate inverse model amplifies the high-frequency response. In this paper, to solve the problem of ZPETC, an adaptive model-inverse control is proposed. The adaptive algorithm updates feedforward term in real-time. The effectiveness of the proposed adaptive model-inverse position control strategy is verified by comparison with typical proportional-integral (PI) control and feedforward control by experiments. As a result, the proposed adaptive controller extends the bandwidth of EHA position control.

비례솔레노이드 액추에이터를 이용한 압력제어밸브 (Pressure Control Valve using Proportional Electro-magnetic Solenoid Actuator)

  • 함영복;박평원;윤소남
    • 대한기계학회논문집A
    • /
    • 제30권10호
    • /
    • pp.1202-1208
    • /
    • 2006
  • This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed.