• Title/Summary/Keyword: Electro activity

Search Result 155, Processing Time 0.026 seconds

Effects of the Gamidokwalgisaeng-tang(GDS) Oral Administration and Electro-acupuncture at Chishil$(BL_{52})$, Hyonjong$(GB_{39})$ on Osteoporotic Rats Induced by Ovariectomy (가미독활기생탕(加味獨活寄生湯)의 경구투여(經口投與)와 지실(志室).현종(懸鍾) 전침(電鍼) 병용(倂用) 시술(施術)이 흰 쥐의 골다공증(骨多孔症)에 미치는 영향(影響))

  • Cho, Myung-Rae;Chae, Woo-Seok;Choi, Won-Hwak
    • Journal of Acupuncture Research
    • /
    • v.23 no.3
    • /
    • pp.1-19
    • /
    • 2006
  • Objectives : This study was carried out to determine the effects of Gamidokwalgisaeng-tang(GDS) oral administration and electro-acupuncture at $BL_{52}$ & $GB_{39}$ on the postmenopausal osteoporosis. Methods: In order to study the effects of the Gamidokwalgisaeng-tang(GDS) oral administration and electro-acupuncture at $BL_{52}$, $GB_{39}$ on osteoporotic rats induced by ovariectomy, body weight, femur weight, uterine weight, serum level of osteocalcin, alkaline phosphatase(ALP), cholesterol, triglyceride, estradiol, androstenedione, testosterone and urinary excretions of calcium & phosphorus were measured. Results : 1. Body weight in all experimental group decreased significantly in comparison with ovariectomized group(OVX). 2. The weight of femur compared with body increased significantly in GDS oral administration and combination treatment group in comparison with ovariectomized group(OVX). 3. Uterine endometrial morphology is caused by ovariectomy and the weight of uterus decreased significantly in control and all experimental group in comparison with sham. 4. The serum level of osteocalcin decreased in all experimental group in comparison with OVX, but significantly in electro-acupuncture and combination treatment group. 5. The serum alkaline phosphatase(ALP) activity decreased in electro-acupuncture and combination treatment group in comparison with OVX, but only significantly in electro-acupuncture group. 6. The serum level of cholesterol increased significantly in OVX in comparison with sham and decreased in all experimental group in comparison with OVX, not insignificantly. The serum level of triglyceride increased in all experimental group in comparison with OVX, not insignificantly. 7. Urinary excretions of calcium and phosphorus decreased significantly in all experimental group in comparison with OVX. Conclusion : We suggest that GDS oral administration and electro-acupuncture at $BL_{52}$ & $GB_{39}$ are available for prevention and curing about the postmenopausal osteoporosis.

  • PDF

Methanol Electro-Oxidation of Electro-Spun RuO2 Nanowire Supported Pt Catalysts (Electro-Spun RuO2 나노선 지지체에 담지된 Pt촉매의 메탄올 Electro-Oxidation 특성)

  • Yeom, Yong-Sik;Ahn, Hyo-Jin
    • Korean Journal of Materials Research
    • /
    • v.21 no.8
    • /
    • pp.419-424
    • /
    • 2011
  • Pt nanoparticle catalysts incorporated on $RuO_2$ nanowire support were successfully synthesized and their electrochemical properties, such as methanol electro-oxidation and electrochemically active surface (EAS) area, were demonstrated for direct methanol fuel cells (DMFCs). After fabricating $RuO_2$ nanowire support via an electrospinning method, two different types of incorporated Pt nanoparticle electrocatalysts were prepared using a precipitation method via the reaction with $NaBH_4$ as a reducing agent. One electrocatalyst was 20 wt% Pt/$RuO_2$, and the other was 40 wt% Pt/$RuO_2$. The structural and electrochemical properties of the Pt nanoparticle electrocatalysts incorporated on electrospun $RuO_2$ nanowire support were investigated using a bright field transmission electron microscopy (bright field TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and cyclic voltammetry. The bright field TEM, XRD, and XPS results indicate that Pt nanoparticle electrocatalysts with sizes of approximately 2-4 nm were well incorporated on the electrospun $RuO_2$ nanowire support with a diameter of approximately 50 nm. The cyclic voltammetry results showed that the Pt nanoparticle catalysts incorporated on the electrospun $RuO_2$ nanowire support give superior catalytic activity in the methanol electro-oxidation and a higher electrochemically active surface (EAS) area when compared with the electrospun Pt nanowire electrocatalysts without the $RuO_2$ nanowire support. Therefore, the Pt nanoparticle catalysts incorporated on the electrospun $RuO_2$ nanowire support could be a promising electrode for direct methanol fuel cells (DMFCs).

Heart Rate Change of Carp Cyprinus Carpio During Swimming Activity (유영운동에 의한 잉어의 심박수변화)

  • 안영일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.24-28
    • /
    • 1995
  • Exercise physiology of fish was studied by means of Electro-cardio-gram(ECG) technique with wired electrode system. Effects of swimming activity on the heart rate change for carp Cyprinus carpio was observed and analysed under swimming speeds among 1~3 Body Length/s and swimming durations of 10 and 60 minutes in the flume tank. The heart rate increase during swimming activity was observed in higher speed and longer duration conditions. The exercise effect on the heart rate continued even after fish stopped swimming. The time for recovery after exercise was tended to be elongated with the higher exercise condition.

  • PDF

Fluorescent Probes for Analysis and Imaging of Monoamine Oxidase Activity

  • Kim, Dokyoung;Jun, Yong Woong;Ahn, Kyo Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1269-1274
    • /
    • 2014
  • Monoamine oxidases catalyze the oxidative deamination of dietary amines and amine neurotransmitters, and assist in maintaining the homeostasis of the amine neurotransmitters in the brain. Dysfunctions of these enzymes can cause neurological and behavioral disorders including Parkinson's and Alzheimer's diseases. To understand their physiological roles, efficient assay methods for monoamine oxidases are essential. Reviewed in this Perspective are the recent progress in the development of fluorescent probes for monoamine oxidases and their applications to enzyme assays in cells and tissues. It is evident that still there is strong need for a fluorescent probe with desirable substrate selectivity and photophysical properties to challenge the much unsolved issues associated with the enzymes and the diseases.

Electro-Chemical Properties of Iridium Oxide Coated Ti Electrode Synthesized by Unbalanced Magnetron Sputtering Process (비대칭 마크네트론 스퍼터링을 이용한 이리듐 산화물 박막의 합성과 전기 화학적 특성분석)

  • Kim, Sung-Dae;Kim, Sang-Sik;Song, Jin-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.5
    • /
    • pp.203-208
    • /
    • 2007
  • Preliminary studies were conducted to develop a dimensionally stable anode (DSA)electrode prepared by reactive sputtering method. The microstructure, surface morphology and electrochemical properties of iridium oxide $(IrO_2)$ coatings synthesized by unbalanced magnetron sputtering (UBMS) and conventional DSA electrode were compared. In addition, the possibilities of $IrO_2$ films synthesized by UMB on a real DSA electrode were investigated by electro-chemical application test. The degree of non-stoichiometry and surface area were closely related to the electro-chemical activity of the $IrO_2$ electrode. The feasibility of making a DSA electrode prepared by PVD technique was demonstrated through the present work.

Electro-Catalytic Behavior of an Antiarrhythmic Drug, Procainamide and its Electro-Analytical Applications

  • Abbar, Jyothi C.;Meti, Manjunath D.;Nandibewoor, Sharanappa T.
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.292-300
    • /
    • 2018
  • The electrocatalytic oxidative behavior of an antiarrhythmic drug, procainamide hydrochloride (PAH) at the gold electrode surface has been examined using different voltammetric methods like cyclic, linear-sweep and differential pulse voltammetry. Voltammograms obtained in this study reveal that the electrode exhibit excellent electrocatalytic activity towards oxidation of the drug. The parameters that can affect the peak current at different pH, scan rate and concentration were evaluated. The number of electrons transferred was calculated. The current displayed a wide linear response ranging from 0.5 to $30.0{\mu}M$ with a limit of detection of 56.4 nM. The impact of potential interfering agents was also studied. The electrode displayed wide advantages such as simple sample preparation, appreciable repeatability, reproducibility and also high sensitivity. Furthermore, the feasibility of the proposed method was successfully demonstrated by determining PAH in the spiked human biological sample.

Stability Characteristics of Sn Species Behavior on Surface of a Sn-modified Pt Electrode for Electrolytic Reduction of Nitrate Ion (질산염 이온의 전해 환원을 위한 Sn-modified Pt 전극 표면에서의 Sn 안정성 거동 특성)

  • Kim, Kwang-Wook;Kim, Seong-Min;Kim, Yeon-Hwa;Lee, Eil-Hee;Jee, Kwang-Yong
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.433-441
    • /
    • 2007
  • This work investigated the stability of a Sn-modified Pt electrode, which was used for reduction of nitrate, fabricated by an adsorption or electro-deposition of Sn on Pt. In order to find the causes for instability of the electrode, the effects of the solutions in which the electrode was used and the potential applied to the electrode on the electrochemical and metallurgical behaviors of Sn on Pt were studied. The Sn of freshly- prepared modified-Sn Pt electrode existed as Sn hydroxide form, which brought about an easy loss of the electro-activity of the electrode even staying in water, especially in acid solution. When the Sn-modified Pt electrode was used for the reduction of nitrate, the electro-activity of the electrode was affected depending on the potential applied to the electrode. When a more negative potential than the redox equilibrium potential between $Sn(OH)_2$ and Sn was applied to the electrode, the Sn hydroxide was converted to Sn that could diffused into Pt, which leaded to the loss of electro-activity of the electrode as well. The solid diffusion of Sn increased linearly with the applied potential. The Sn-electrodeposited Pt electrode which had more Sn on the electrode was more favorable to maintaining the integrity of the electrode during the reduction of nitrate than the Sn-adsorbed Pt electrode prepared in the under-potential deposition way.

Anti-oxidative and immune-regulative Effects of Electro-acupuncture at SP6 in Aged Rats (삼음교(三陰交) 전침이 노화과정 흰쥐의 항산화능 및 면역능에 미치는 영향)

  • Song, Jong-Keun;Lee, Byung-Ryul;Yang, Gi-Young;Jeon, Ju-Hyun;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.87-106
    • /
    • 2010
  • Objective & Methods: The purpose of this study is to investigate the anti-oxidative and immuneregulative effects of electro-acupouncture(EA) at SP6(Sameumgyo) in aged rats. The author performed several experimental items including blood cell counts, blood chemistry, measurement of various oxidants and antioxidants in liver and spleen, analysis of various cytokines in spleen. The results are as follows. Results: 1. EA at SP6 significantly reduced the number of platelets in blood. 2. EA at SP6 significantly reduced NO concentration and significantly increased catalase activity in liver. 3. EA at SP6 significantly reduced NO concentration and significantly increased SOD activity, catalase activity and glutathione concentration in spleen. 4. EA at SP6 restored the increase of IL-4, IL-6 and the decrease of IFN-$\gamma$ in aged rat spleen. Conclusion: According to these results, it is postulated that EA at SP6 has an antioxidative effect through increasing the activities of antioxidative enzymes and inhibiting production of oxidized substances, as well as an immune regulative effect in aging process. In consequence, it is presumed that EA at SP6 may have an anti-aging effect.

Effect of Electro-stimulation on Stability of Alcohol Dehydrogenase from Horse Liver (알콜 탈수소효소의 안정도에 미치는 전기 자극의 효과)

  • Lee Kang-Min;Kim Chunl-Sang;Lee Hye-Jung;Hahm Dae-Hyun;Park Chung-Ung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.6
    • /
    • pp.1723-1727
    • /
    • 2004
  • We investigated the activity and stability of alcohol dehydrogenase from horse liver (HLADH) under the electric stimulation. The activity and stability of alcohol dehydrogenase depended on electric output voltaqe, stimulation time, pulse duration and pulse interval, and temperature. HLADH retained about 23% of its activity in buffer but 78% in 10% trehalose solution under electric stimulation with 10V, 10min, The stabilizing of enzymes against electric stimulation by stabilizing additives showed a great potential use of enzymes in biotechnology and medical engineering fields.