• Title/Summary/Keyword: Electro Impedance

Search Result 180, Processing Time 0.027 seconds

New Impedance Matching Scheme for 60 GHz Band Electro-Absorption Modulator Modules

  • Choi, Kwang-Seong;Chung, Yong-Duck;Kang, Young-Shik;Jun, Dong-Suk;Ahn, Byoung-Tae;Moon, Jong-Tae;Kim, Je-Ha
    • ETRI Journal
    • /
    • v.28 no.3
    • /
    • pp.393-396
    • /
    • 2006
  • This letter proposes a new impedance matching scheme of a traveling wave electro-absorption modulator (TWEAM) module for a 60 GHz band radio-over-fiber (ROF) link. A microstrip band pass filter (BPF) was used to achieve impedance matching at the 60 GHz band, and termination resistance was carefully designed to obtain an input impedance close to $50\;{\Omega}$. Also, a bias circuit for the device was designed in the module. The measured return loss and frequency response show that the modulator module observes the characteristics of a filter without the need of a further tuning process.

  • PDF

Hybrid Monitoring for Damage Detection in Structural Joints (구조 접합부의 손상검색을 위한 하이브리드 모니터링)

  • Kim Jeong-Tae;Na Won-Bae;Lee Byung-Jun;Hong Dong-Soo;Do Han-Sung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.225-231
    • /
    • 2006
  • The purpose of this study is to develop a promising hybrid structural health monitoring system for structural joints. For this propose, the combined use of vibration-based techniques and electro-mechanical impedance technique is employed. For the verification of the proposed health monitoring scheme, a series of damage scenarios are designed to simulate various situations at which the connection joints can experience during their service life. The obtained experimental results, modal parameters and electro-magnetic impedance signatures, are carefully analyzed to recognize the connecting states and the target damage locations. From the analysis. it is shown that the proposed hybrid health monitoring system is successful for acquiring global and local damage information on the structural joints.

  • PDF

Electro-mechanical impedance based monitoring for the setting of cement paste using piezoelectricity sensor

  • Lee, Jun Cheol;Shin, Sung Woo;Kim, Wha Jung;Lee, Chang Joon
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.123-134
    • /
    • 2016
  • The evolution of the electro-mechanical impedance (EMI) of a piezoelectricity (PZT) sensor was investigated to determine the setting times of cement paste in this study. The PZT sensor coated with non-conductive acrylic resin was embedded in fresh cement paste and the EMI signatures were continuously monitored. Vicat needle test and semi-adiabatic calorimetry test were also conducted to validate the EMI sensing technique. Significant changes in the EMI resonance peak magnitude and frequency during the setting period were observed and the setting times determined by EMI sensing technique were relevant to those measured by Vicat needle test and semi-adiabatic calorimetry test.

Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges

  • Kim, Jeong-Tae;Park, Jae-Hyung;Hong, Dong-Soo;Cho, Hyun-Man;Na, Won-Bae;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • v.5 no.1
    • /
    • pp.81-94
    • /
    • 2009
  • A vibration-impedance-based monitoring method is proposed to predict the loss of prestress forces in prestressed concrete (PSC) girder bridges. Firstly, a global damage alarming algorithm using the change in frequency responses is formulated to detect the occurrence of damage in PSC girders. Secondly, a local damage detection algorithm using the change in electro-mechanical impedance features is selected to identify the prestress-loss in tendon and anchoring members. Thirdly, a prestress-loss prediction algorithm using the change in natural frequencies is selected to estimate the extent of prestress-loss in PSC girders. Finally, the feasibility of the proposed method is experimentally evaluated on a scaled PSC girder model for which acceleration responses and electro-mechanical impedances were measured for several damage scenarios of prestress-loss.

Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme (다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안)

  • Lee, Seok-Young;Nam, Yoon-Key
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.

Hybrid Damage Monitoring Technique for Bridge Connection Via Pattern-Recognition of Acceleration and Impedance Signals (가속도 및 임피던스 신호의 특징분류를 통한 교량 연결부의 하이브리드 손상 모니터링 기법)

  • Kim, Jeong-Tae;Na, Won-Bae;Hong, Dong-Soo;Lee, Byung-Jun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.57-65
    • /
    • 2006
  • This paper presents hybrid structural damage monitoring system which performs both global damage assessment of structure and damage detection of local structural joints. Hybrid damage monitoring system is composed of vibration-based technique and electro/mechanic impedance technique. Vibration-based technique detects global characteristic change ot structure using modal characteristic change of structure, and electro/mechanical impedance technique detects damage existence of local structural joints using impedance change of PZT sensor. For the verification of the proposed hybrid monitoring system, a series of damage scenarios are designed to loosened bolts situations of the structural joints, and acceleration response and impedance response signatures are measured. The proposed hybrid monitoring system is implemented to monitor global damage-state and local damages in structural joints.

Impedance-based Long-term Structural Health Monitoring for Tidal Current Power Plant Structure in Noisy Environments (잡음 환경 하에서의 전기-역학적 임피던스 기반 조류발전 구조물의 장기 건전성 모니터링)

  • Min, Ji-Young;Shim, Hyo-Jin;Yun, Chung-Bang;Yi, Jin-Hak
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.59-65
    • /
    • 2011
  • In structural health monitoring (SHM) using electro-mechanical impedance signatures, it is a critical issue for extremely large structures to extract the best damage diagnosis results, while minimizing unknown environmental effects, including temperature, humidity, and acoustic vibration. If the impedance signatures fluctuate because of these factors, these fluctuations should be eliminated because they might hide the characteristics of the host structural damages. This paper presents a long-term SHM technique under an unknown noisy environment for tidal current power plant structures. The obtained impedance signatures contained significant variations during the measurements, especially in the audio frequency range. To eliminate these variations, a continuous principal component analysis was applied, and the results were compared with the conventional approach using the RMSD (Root Mean Square Deviation) and CC (Cross-correlation Coefficient) damage indices. Finally, it was found that this approach could be effectively used for long-term SHM in noisy environments.

Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder

  • Park, Jae-Hyung;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1159-1175
    • /
    • 2015
  • In this study, the effect of temperature variation on the wireless impedance monitoring is analyzed for the tendon-anchorage connection of the prestressed concrete girder. Firstly, three impedance features, which are peak frequency, root mean square deviation (RMSD) index, and correlation coefficient (CC) index, are selected to estimate the effects of temperature variation and prestress-loss on impedance signatures. Secondly, wireless impedance tests are performed on the tendon-anchorage connection for which a series of temperature variation and prestress-loss events are simulated. Thirdly, the effect of temperature variation on impedance signatures measured from the tendon-anchorage connection is estimated by the three impedance features. Finally, the effect of prestress-loss on impedance signatures is also estimated by the three impedance features. The relative effects of temperature variation and prestress-loss are comparatively examined.

Electrical Impedance Tomography as a Primary Screening Technique for Breast Cancer Detection

  • Akhtari-Zavare, Mehrnoosh;Latiff, Latiffah A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5595-5597
    • /
    • 2015
  • Electrical impedance tomography (EIT) is a new non-invasive, mobile screening method which does not use ionizing radiation to the human breast. It is based on the theory that cancer cells display altered local dielectric properties, thus demonstrating measurably higher conductivity values. This article reviews the utilisation of EIT in breast cancer detection. It could be used as an adjunct to mammography and ultrasonography for breast cancer screening.

The Corrosion Behavior Study by AC Impedance Method for the Aging Heat Treated Nimonic 80A Superalloy (교류임피던스법에 의한 Nimonic 80A 초내열합금 시효열처리재의 부식거동 고찰)

  • 백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.761-769
    • /
    • 1999
  • In this paper the effect of aging heat treatment to the Corrosion behavior for the Nimonic 80A superalloy was studied by AC Impedance methods. Tested solution was 3.5% with tempera-ture $25^{\circ}C$ Electro-chemical corrosion test were carried out for the Nimonic 80A super-alloy which solution heat treated at $1080^{\circ}C$ for 8 hours followed by aging heat treated at $650^{\circ}C,\;700^{\circ}C,\;750^{\circ}C\;800^{\circ}C$ and $850^{\circ}C$ with 16hours under vacuum environment. The obtained results were as follows; 1. Base metal and solution-treated materials were exhibited similar corrosion tendency as Ran-dle equivalent cell. The value of passive film resistance was 579 ohms for the base metal and 124,770 ohms for the solutionized metal such a difference was arose by the ${{\gamma}_^'}$ precipitate on the metal surface during heat treatment. 2. The measure value of $R_p$ for heat-treated at $650^{\circ}C,\;700^{\circ}C,\;800^{\circ}C$and $850^{\circ}C$ were 97,943, 93, 111, 26,961, 15,798 and 11,780ohm respectively. Which indicated that the passive film resistance Rp was reduced as aging temperature increased due to the growth of grain size and sensitization at the grain boundary. 3. The similar tendency was exhibited for corrosion behavior of the electro-chemical corrosion polarization method and AC impedance method and confirmed that AC impedance method was useful tool for corrosion research.

  • PDF