• 제목/요약/키워드: Electricity Load

검색결과 515건 처리시간 0.022초

최적의 부하소비전략 수립을 위한 새로운 부하관리시스템 패키지 응용에 관한 연구 (Application of New Load Management System Package for Development of the Optimal Electricity Consumption Strategy)

  • 정구형;김진호;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.602-605
    • /
    • 2003
  • This paper describes the consumer's decision-making process fur own optimal electricity consumption schedule and strategy using new load management system (LMS). As a result, it is demonstrated that a consumer in competitive electricity market has the opportunities to reduce electric payment by use of this LMS.

  • PDF

냉방전력수요분석 및 관리방안 (ANALYSIS AND MANAGEMENT OF SUMMER COOLING LOAD)

  • 남정일;김문덕;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.152-155
    • /
    • 1991
  • The analysis and forecast of summer cooling load is one of the major concerns of utility company(KEPCO). In this paper, various methodologies to assess the weather sensitive load are introduced and the cause of remarkable growth of the summer cooling load in the last years are analized. To establish the effective measures to migrate the peak building by the summer cooling, a number of practical institutional policies are offered for future implementation.

  • PDF

전력시장에서 용량요금 메커니즘 변화의 영향과 개선 (A Study on the Amendment of Base Load Market and CP in Electricity Market)

  • 김창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.255-257
    • /
    • 2007
  • Korea electricity market consists of two payment systems, capacity and energy. Capacity payments are given to the generators according to its hourly availability considering hourly and seasonal weighting factors. Energy payments are settled at the marginal generation cost based on generator variable cost. In 2007, base load energy market is closed and single capacity payment system is begun to apply in electricity market. In this revised market rule, energy price cap for base load generators is newly introduced. We analyze impact of market rule revision in 2007 on base load generators and suggest improvement scheme to enforce market system in this study.

  • PDF

부하패턴을 이용한 전력시장 정보의 불완비성 추정에 관한 연구 (The Estimation of Incomplete Information in Electricity Markets by Using Load Pattern Changes)

  • 신재홍;이광호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.848-853
    • /
    • 2007
  • This paper presents a methodology of estimating incomplete information in electricity markets for analyzing the gaming behavior of Generating Companies (GENCOs). Each GENCO needs to model its opponents' unknown information of strategic biddings and cost functions. In electricity markets with complete information, each GENCO knows its rivals' payoff functions and tries to maximize its own profit at Nash equilibriurnl Nli) by acknowledging the rivals' cost function. On the other hand, in the incomplete information markets, each GENCO lacks information about its rivals. Load patterns can change continuously due to many factors such as weather, price, contingency, etc. In this paper, we propose the method of the estimation of the opponents' cost function using market price, transaction quantities. and customer load patterns. A numerical example with two GENCOs is illustrated to show the basic idea and effectiveness of the proposed methodology.

RNN을 활용한 도시철도 역사 부하 패턴 추정 (Estimation of Electrical Loads Patterns by Usage in the Urban Railway Station by RNN)

  • 박종영
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1536-1541
    • /
    • 2018
  • For effective electricity consumption in urban railway station such as peak load shaving, it is important to know each electrical load pattern by various usage. The total electricity consumption in the urban railway substation is already measured in Korea, but the electricity consumption for each usage is not measured. The author proposed the deep learning method to estimate the electrical load pattern for each usage in the urban railway substation with public data such as weather data. GRU (gated recurrent unit), a variation on the LSTM (long short-term memory), was used, which aims to solve the vanishing gradient problem of standard a RNN (recursive neural networks). The optimal model was found and the estimation results with that were assessed.

피크부하용 혼소엔진발전의 경제성 분석 (An Economic Analysis on Dual-fuel Engine Generation for Peak Load)

  • 이옥배;안재경
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1260-1268
    • /
    • 2012
  • Recently, lack of power reserve margin was observed quite often. In this paper, we studied the method to secure power source for a short time, to cut the utility power peak load, and to reduce the users electricity bills. Emergency diesel generator of an office building is to be converted into a dual-fuel engine generator which is responsible for a portion of the peak load. Compared to the conventional diesel fuel generator, the proposed dual-fuel engine is able to reduce the generation power cost by dual-fuel combustion, and it also mitigates the building's utility power peak load by charging the building's peak load. If the dead resources (a group of emergency dual-fuel engine generators), as a Virtual Power Plant, are operating in peak time, we can significantly reduce future large power development costs. We investigated the current general purpose electricity bills as well as the records of the building electric power usage, and calculated diesel engine generator renovation costs, generation fuel costs, driving conditions, and savings in electricity bills. The proposed dual-fuel engine generation method reduces 18.1% of utility power peak load, and turned out to be highly attractive investment alternative which shows more than 27% of IRR, 76 million won of NPV, and 20~53 months of payback periods. The results of this study are expected to be useful to developing the policy & strategy of the energy department.

원격제어 에어컨 개발 보급현황 및 향후전망 (A development of direct load control system for air-conditioner)

  • 강원구;김충환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF

퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구 (A Study on Daily Cooling Load Forecast Using Fuzzy Logic)

  • 신관우;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.

제주도의 특수일 전력수요에 대한 기온 민감도 분석 (Sensitivity Analysis of Temperature on Special Day Electricity Demand in Jeju Island)

  • 조세원;박래준;김경환;권보성;송경빈;박정도;박해수
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1019-1023
    • /
    • 2018
  • In this paper sensitivity analysis of temperature on special day electricity demand of land and Jeju Island is performed. The basic electricity demand per 3 hours is defined as electricity demand that reflects the GDP effect without the temperature influence. The temperature sensitivity per 3 hours is calculated through the relationship between special day electricity demand normalized to basic electricity demand and temperature. In the future, forecast error will be improved if the temperature sensitivity per 3 hours is applied to the special day load forecasting.

넷 제로에너지주택의 부하매칭에 관한 연구 (A Study of Load Matching on the Net-Zero Energy House)

  • 김법전;임희원;김덕성;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제38권4호
    • /
    • pp.55-66
    • /
    • 2018
  • nZEH (net-Zero Energy House) is defined as a self-sufficient energy building where the sum of energy output generated from new & renewable energy system and annual energy consumption is zero. The electricity generated by new & renewable energy system with the form of distributed generation is preferentially supplied to electrical demand, and surplus electricity is transmitted back to grid. Due to the recent expansion of houses with photovoltaic system and the nZEH mandatory by 2025, the rapid increase of distributed generation is expected. Which means, we must prepare for an electricity-power accident and stable electricity supply. Also electricity charges have to be reduce and the grid-connected should be operated efficiently. The introduction of ESS is suggested as a solution, so the analysis of the load matching and grid interaction is required to optimize ESS design. This study analyzed the load matching and grid interaction by expected consumption behavior using actual data measured in one-minute intervals. The experiment was conducted in three nZEH with photovoltaic system, called all-electric houses. LCF (Load Cover Factor), SCF (Supply Cover Factor) and $f_{grid}$ (Grid Interaction Index) were evaluated as an analysis indicator. As a result, LCF, SCF and $f_{grid}$ of A house were 0.25, 0.23 and 0.27 respectively; That of B house were 0.23, 0.23, 0.19, and that of C were 0.20, 0.19, 0.27 respectively.