• Title/Summary/Keyword: Electricity Load

Search Result 515, Processing Time 0.028 seconds

A Design of Incentive-based DR Program using Analytic Hierarchy Process(AHP) (계층분석과정(AHP)을 이용한 지원금 기반 수요반응프로그램 설계)

  • Kim, Dong-Min;Kim, Young-Hyun;Kim, Jin-O;Lee, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.589_590
    • /
    • 2009
  • This paper presents a unique approach to scheme a demand response (DR) program in the electricity market from a customer-oriented perspective, which is based on the analytic hierarchy process (AHP). The proposed program is designed as an incentive-based program (IBP) considering Korea power systems with the cost-based generation pool (CBP). And the proposed DR program has the objective to maximize social welfare corresponding customers‘ participation and the constraints including incentive payments, the specific load curtailment conditions and reserve-margin criterion. A test system for the case study is used to demonstrate the usefulness and applicability of the proposed approach, and the load profiles with the proposed DR program are obtained. The results show not only the revenue attributable to the avoided costs but also enhancement of system reliability.

  • PDF

Generation Mix Analysis based on the Screening Curve and WASP-IV Techniques (탐색곡선법과 WASP-IV 모형을 이용한 국내 적정 전원구성 분석)

  • Jang, Se-Hwan;Park, Jong-Bae;Roh, Jae-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.534-541
    • /
    • 2012
  • This paper tries to elicit an optimal generation mix of Korea. Two approaches, using the screening curve method and taking advantage of a generation expansion planning tool, WASP-IV, are applied in getting the mix. The data used in this study is based on the 5th basic plan for long-term electricity supply and demand. The Load Duration Curve, that is needed for applying Screening Curve Method(SCM), is made based on the load profile in 2010. In our using SCM, the nuclear plant's operation characteristic, carbon emission cost and spinning reserve are considered. In using WASP-IV to get the adequate generation mix, the base and target demand forecasts in the 5th basic plan are used and the carbon emission cost is also considered. In this paper, It introduces the domestic adequacy generation mix in 2024 though SCM and WASP-IV.

On the Control of Re-Structured Electric Power Systems

  • Feliachi Ali
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.363-375
    • /
    • 2005
  • The paper describes some of the challenges that face the control of nonlinear interconnected power systems. The challenges include the selection of appropriate control and information structures that could range from a completely decentralized to a fully centralized structure. Once a structure is proven to be feasible, the effectiveness of control signals needs to be assessed. Analytical tools are derived for this purpose in the first part of the paper, and they are illustrated with a case study that involves the design of a damping decentralized controller using a Thyristor Controlled Series Compensation device. The second part of the paper deals with the load following and tracking problem through automatic generation control for a system that has been re-structured or deregulated. This problem can be solved using a completely decentralized scheme. It is solved here using fuzzy rules and with an emphasis on compliance with NERC's standards and reduction of wear and tear of the equipment. It is illustrated with a test system that has three interconnected control areas. Finally, comments on the economics of control and the author's vision are presented.

A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator (PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발)

  • Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.

A research of optimum supply reserve levels for stability of power system (전력계통 안정을 위한 공급예비력 적정수준에 대한 연구)

  • Ahn, Dae-Hoon;Kwon, Seok-Kee;Joo, Haeng-Ro;Shin, Jung-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.61-65
    • /
    • 2008
  • Because of the high increasing rate of load demand, these days the necessity of deciding what optimum reserve level is appropriate to most stably supply electricity is being emphasized. This research studies the downward tendency of reverve ratio by analyzing the trend of change of the network scale, reserve, and reserve ratio while optimum reserve has been increased as the network system scale grow up. This means, at this moment 6,000MW is optimum level for short term prospect of power supply and demand. And also, it has been analyzed that, as the annual peak load exceeded 50,000MW, confirming the amount of optimum reserve level is more stable than keeping 10 to 12% reserve ratio.

  • PDF

Control Strategy and Characteristic Analysis of PEMFC/Photovoltaics Hybrid Vehicle (연료전지-태양전지 하이브리드 자동차에 대한 제어전략 및 특성평가)

  • Ahn, Hyo-Jung;Ji, Hyun-Jin;Bae, Joong-Myeon;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.840-847
    • /
    • 2007
  • This Paper focuses on modeling and simulation to analyze the characteristic of hybrid vehicle. The system includes a proton exchange membrane fuel cell(PEMFC), photovoltaic generator(PV), lead-acid battery, motor, vehicle and controller. Main electricity is produced by the PEMFC and battery to meet the requirements of a user load. When vehicle is parked in a sunny place, extra power is generated by the photovotaics and is charged in a battery for next drive. Further we evaluate usefulness of this hybrid vehicle by using ADVISOR - the advanced vehicle simulator written in the Matlab/Simulink environment. According to simulation results, the extra power obtained by photovoltaics which have been explored in nature conditions can help to reduce the electrical load of PEMFC and increase the efficiency (over 21 %).

A study on capacitive transformer (용량성배전변압기에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.18 no.2
    • /
    • pp.7-14
    • /
    • 1969
  • From the first customer located right at the substation to the last customer at the end of the line, voltage must be held within close limits, so the voltage regulation is more important than the thermal limit. On a typical distribution system during the peak load period, the voltage drop may be serious enough to cause unsatisfactory operation of home appliances in the residential area, and present many problems to manufacturing industries, where the voltage must be maintained within close limits to insure smooth operation. Among all the factors contributing to voltage drop in the distribution system, the voltage drop in the distribution transformer may account for 30% of this figure. If we can eliminate this factor, the power companies can provide better quality electricity to more customers with the existing distribution facilities, thus saving on initial investment costs. Taking all these problems into consideration, the author undertook the design of a capacitive transformer which would give zero voltage drop at rated load and at 80% lagging power factor while incorporating overload features to withstand 400% overload for at least 100 seconds. The following are the results obtained through design, manufacture and test of an initial experimental transformer built with these specific purposes.

  • PDF

Development of a Energy Demand Estimator for Community Energy Systems (건물 단지에 대한 에너지 수요 예측 데이터베이스 응용 프로그램 개발)

  • Chung, Mo;Park, Hwa-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.37-44
    • /
    • 2009
  • The field-surveyed and measured energy consumption data is processed to develop building energy demand models for heating, hot water, cooling, and electricity. The load models are systematically organized as a database and hourly loads for a span of year (8760 hours) are generated by the program. Rased on those models a Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of 17 types of buildings. User-friendly interfaces are provided to assist non-expert end users and necessary tools to link the calculation results to subsequent coagulations such as operation simulation or economic assessment.

The DSM application technique for EHP (전기식 히트펌프(EHP)의 전력수요관리 적용기술)

  • Yang, Seung-Kwon;Lee, Han-Byul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.61-64
    • /
    • 2008
  • This paper gives the application method for Electric Heat Rump to DSM programs. The EHP has a function transfer heat and uses electricity as a energy source. In nowadays, as oil prices go up, many People uses the EHP, instead of GHP, the electric power peak load is escalating gradually. By that reason, to achieve successful load leveling, new DSM programs for EHP is needed. Under those circumstances, we discussed about the need of DSM programs for EHP, and the detail method for application EHP to DSM programs in this paper. And we dealt with the site specific test for EHP, and analyzed the test result.

  • PDF

Inverter Systems of Constant Current Regulate by Using Advanced Measurement and Switching Techniques (개선된 계측 및 스위칭 기법을 이용한 정전류조정 인버터 시스템)

  • Shon, Jin-Geun;Seo, Il-Dong;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.173-178
    • /
    • 2007
  • As development of industry is accelerated, most electricity load system requires power supply that could be high precision and effective control. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting & beaconing of aerodromes and electric heating system. Therefore, in this paper proposed a inverter systems of constant current regulate that using improved measurement and switching techniques. Proposed measure techniques that used moving average method of instantaneous r.m.s. for measuring current sensing improved response and precision. Also, in this paper proposed improved high effectiveness switching techniques that get high efficiency of inverter by the double-carrier modulation. Results of an experiment proved effect of proposed system.