• Title/Summary/Keyword: Electricity Load

Search Result 515, Processing Time 0.022 seconds

Study on BESS Charging and Discharging Scheduling Using Particle Swarm Optimization (입자 군집 최적화를 이용한 전지전력저장시스템의 충·방전 운전계획에 관한 연구)

  • Park, Hyang-A;Kim, Seul-Ki;Kim, Eung-Sang;Yu, Jung-Won;Kim, Sung-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.547-554
    • /
    • 2016
  • Analyze the customer daily load patterns, be used to determine the optimal charging and discharging schedule which can minimize the electrical charges through the battery energy storage system(BESS) installed in consumers is an object of this paper. BESS, which analyzes the load characteristics of customer and reduce the peak load, is essential for optimal charging and discharging scheduling to save electricity charges. This thesis proposes optimal charging and discharging scheduling method, using particle swarm optimization (PSO) and penalty function method, of BESS for reducing energy charge. Since PSO is a global optimization algorithm, best charging and discharging scheduling can be found effectively. In addition, penalty function method was combined with PSO in order to handle many constraint conditions. After analysing the load patterns of target BESS, PSO based on penalty function method was applied to get optimal charging and discharging schedule.

Wide-Input Range Dual Mode PWM / Linear Buck Converter with High robustness ESD Protection Circuit

  • Song, Bo-Bae;Koo, Yong-Seo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.292-300
    • /
    • 2015
  • This paper proposes a high-efficiency, dual-mode PWM / linear buck converter with a wide-input range. The proposed converter was designed with a mode selector that can change the operation between PWM / linear mode by sensing a load current. The proposed converter operates in a linear mode during a light load and in PWM mode during a heavy load condition in order to ensure high efficiency. In addition, the mode selector uses a bit counter and a transmission gate designed to protect from a malfunction due to noise or a time-delay. Also, in conditions between $-40^{\circ}C$ and $140^{\circ}C$, the converter has variations in temperature of $0.5mV/^{\circ}C$ in the PWM mode and of $0.24mV/^{\circ}C$ in the linear mode. Also, to prevent malfunction and breakdown of the IC due to static electricity, the reliability of IC was improved by embedding a self-produced 8 kV-class(Chip level) ESD protection circuit of a P-substrate Triggered SCR type with high robustness characteristics.

A Study on the Development of Energy Simulation Program for Non-specialist to Enhance Green Remodeling (그린리모델링 활성화를 위한 비전문가용 에너지 소비량 산정 프로그램 개발연구)

  • Bang, Sun-Kyu;Yoo, Jung-Hyun;Kim, Du-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.55-62
    • /
    • 2018
  • To receive financial support for the Green Remodeling, applicants must submit an energy simulation report. However, many of the applicants are not green remodeling specialist and energy simulation services are too expensive for them. For this reason, this study was to develop an energy simulation program to enhance green remodeling for the non-specialist such as housewives. Firstly, to enhance understanding and accessibility improvement energy simulation, simulation process was designed four steps and reducing input data. Specifically, input data was reduced by categorizing the following for the area, plan type, hot water load, electricity load, statistical inference. And then, to accurately verify the calculation result, the heat and hot water demand were derived and compared with ECO2 and Energy # program. Lastly, the calculation shows that there is a difference of 4% for the heat load and 15% to 33% for the hot water load respectively.

A Study of Cooling and Heating Load Changes with Roof Type Solar Panels Installed on Factory Roof (지붕형 태양광발전 패널의 공장 지붕 설치에 따른 냉방 및 난방 부하 변화량 연구)

  • Jo, Ho-Hyeon;Kim, Jung-Min;Kim, Young Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.9-15
    • /
    • 2020
  • In this study, effect of reinforced insulation on heating and cooling loads were studied due to installation of PV panels on factory building roof with a floor area of 12,960 m2. For PV panel installation, combination of aluminum, polyurethane, air, polystyrene and steel materials were added to the original roof, which increased thermal insulation performance. Half of the roof were covered with PV panel and the other half without. Temperature and relative humidity were measured for 8 days during summer season for both indoor spaces. PV panel showed the effect of lowering the indoor space temperature by 0.6℃. TRNSYS dynamic simulation showed that with PV panel, cooling load per area is reduced by 1.7 W/m2 and heating by 10.0 W/m2. PV panels installed on building roof not only generate electricity but also can save energy by reducing cooling and heating loads.

A Benefit-Cost Analysis on the DSM Programs Part I (DSM 프로그램의 비용효과 분석 I)

  • Hwang, Sung-Wook;Kim, Bal-Ho;Kim, Jung-Hoon;Park, Jong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.46-48
    • /
    • 2000
  • This paper presents an approach to B/C analysis amenable to evaluate the impact of DSM programs especially on the strategic conservation programs and the load management programs. The proposed approach embedding the existing B/C analyses is applicable to the new electricity market Case studies show the B/C ratio and the avoided cost due to the impact of DSM programs.

  • PDF

A Benefit-Cost Analysis on the DSM Programs Part II (DSM 프로그램의 비용효과 분석 II)

  • Park, Jong-Bae;Kim, Jin-Ho;Hwang, Sung-Wook;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.190-192
    • /
    • 2000
  • This paper presents an approach to B/C analysis amenable to evaluate the impact of DSM programs especially on the strategic conservation programs and the load management programs. The proposed approach embedding the existing B/C analyses is applicable to the new electricity market. Case studies show the B/C ratio and the avoided cost due to the impact of DSM programs.

  • PDF

A Value-based Real Time Pricing Under Imperfect Information on Consumer Behavior (불완전한 수요 정보에 의한 실시간 요율)

  • Kang, Dong-Joo;Kim, Bal-ho;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1202-1204
    • /
    • 1999
  • This paper proposes a value-based pricing suitable for deregulation situation in electricity market, where the value is measured based on the service quality such as system reliability. The proposed approach makes it possible to maximize social welfare, in that diversified service can produce the optimal combination set of demand and supply. The proposed pricing can also be applied to a direct load control.

  • PDF

단결정 태양전지의 시정수

  • Jeong, Yu-Ra;Choe, Yong-Seong;Lee, Gyeong-Seop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.11-11
    • /
    • 2010
  • Recently, annual usage of energy is dramatically increasing by industrialization is going faster and more electricity is needed due to various electronic devices. This paper present relationships between the Vmax, $V_T$, load and time constant of solar cell charge and discharge curve. Charging and discharging recording where the external resistance will become larger Vmax, $V_T$ is decrease and the time increases and decreases there is a possibility of knowing.

  • PDF

Polynomial Type Electricity Price Load Model (다항식 전력 가격 부하 모형)

  • Choi, Joon-Young;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.556-558
    • /
    • 2001
  • 전압 주파수 부하 모형 추정에 사용되어 이전의 정임피던스, 정전류, 정전력 부하모형에 비해 향상된 결과를 얻었던 다항식형 부하 모형을 전력가격 부하 모형에도 적용하여 새로운 다항식 부하 모형을 제안하고, 우리나라의 전력 가격과 사용량 자료를 이용하여 부하 모형의 계수를 결정하였다. 부하의 종류별, 시간대별로 추정된 부하 모형에 부하의 구성 비율을 가중하면 결국 전체 부하 모형이 구해진다. 구해진 부하 모형은 전력 시장이 도입된 경쟁체제에서 전력의 가격 결정에 사용될 수 있을 것이다.

  • PDF

Duplex configuration of UPS output using small-sized STS(Source Transfer Switch) (소형STS(Source Transfer Switch)를 이용한 UPS출력의 이중화)

  • Hwang, Dong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.131-135
    • /
    • 2005
  • Stabilization of electric power is the most important thing is such place as computing center having business critical equipment. However, ability to cope with electrical quality shift and power failure is very weak from UPS output side to load in those electricity system, though UPS is generally used for power stabilization. this problem can be solved by duplication of power source using newly configured UPS and small sized transfer switch even in case of UPS failure.

  • PDF