• Title/Summary/Keyword: Electricity Energy

Search Result 2,002, Processing Time 0.025 seconds

Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus (전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

Analysis of the Effect of Korea's Environmentally Harmful Subsidy Reform in the Electric Power Sector : Mainly on its Industrial Cross-subsidies Reform (우리나라 전력부문의 환경유해보조금 개편 효과분석 : 산업용 교차보조금 개편을 중심으로)

  • Kang, Man-Ok;Hwang, Uk
    • Journal of Environmental Policy
    • /
    • v.9 no.1
    • /
    • pp.57-81
    • /
    • 2010
  • Since the Republic of Korea is highly dependent on fossil fuels despite high oil prices, it urgently needs to renew its economic and social system to cut carbon emissions and achieve green growth. Therefore, reforming or eliminating subsidies related to the use of fossil fuels is a timely and oppropriate policy recommendation for Korea. It would be a win-win deal for Korean society as it would not only reduce the use of environmentally harmful fossil fuels but also enhance economic efficiency. In particular, cross-subsidies for industrial, agricultural and night thermal-storage power services make up more than 80 percent of all subsidies provided to the entire electric power industry sector of Korea. Of these cross-subsidies, this paper analyzes the electricity subsidy for industries, which takes up the largest share (about KRW 1.6583 trillion yearly), among the environmentally harmful subsidies in the electric power sector. Thus, the paper focuses on the analysis of ripple effect anticipated when this is reformed. To examine the effects of this subsidy reform, price elasticities were estimated using the ARDL (autoregressive distributed lag) model and quarterly data from 1990 to 2007. The main results of this study show that 1) annual energy demand for electric power in the industrial sector would drop by 12,475,930MWh and 2) $CO_2$ emissions would plummet by 2,644,897 tons per year if the subsidy were reformed. We can deduct from this that the abolition of environmentally harmful subsidies in the electric power sector in the Republic of Korea would considerably contribute to $CO_2$ emissions abatement in the country.

  • PDF

A Study on the Changes in Heavy Metal Emissions when Using Mixed Fuel in a Thermal Power Plant (화력발전소의 혼합연료 사용에 따른 중금속 배출량 변화 연구)

  • Song, Youngho;Kim, Ok;Park, Sanghyun;Lee, Jinheon
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.63-75
    • /
    • 2018
  • Objectives: The aim of this research is to explore the total heavy metals from a coal-fired power plant burning bituminous coal with wood pellets due to the implementation of the Renewable Portfolio Standard policy (RPS, 10% of electricity from renewable energy resources by 2023). Methods: The research was carried out by collecting archival data and using the USEPA's AP-42 & EMEP/EEA compilation of emission factors for use in calculating emissions. The Monte Carlo method was also applied for carrying out the calculations of measurement uncertainty. Results: In this paper, the results are listed as follows. Sb was measured at 110 kg (2015) and calculated as 165 kg (2019) and 201 kg (2023). Cr was measured at 1,597 kg (2015) and calculated as 1,687 kg (2019) and 1,728 kg (2023). Cu was measured at 2,888 kg (2015) and calculated as 3,133 kg (2019) and 3,264 kg (2023). Pb was measured at 2,580 kg (2015) and calculated as 2,831 kg (2019) and 2,969 kg (2023). Mn was measured at 3,011 kg (2015) and calculated as 15,034 kg (2019) and 23,014 kg (2023). Hg was measured at 510 kg (2015) and calculated as 513 kg (2019) and 537 kg (2023). Ni was measured at 1,720 kg (2015) and calculated as 1,895 kg (2019) and 1,991 kg (2023). Zn was measured at 7,054 kg (2015) and calculated as 9,938 kg (2019) and 11,778 kg (2023). Se was measured at 7,988 kg (2015) and calculated as 7,663 kg (2019) and 7,351 kg (2023). Conclusion: This shows that most heavy metals would increase steadily from 2015 to 2023. However, Se would decrease by 7.9%. This analysis was conducted with EMEP/EEA's emission factors due to the limited emission factors in South Korea. Co-firewood pellets in coal-fired power plants cause the emission of heavy metals. For this reason, emission factors at air pollution control facilities would be presented and the replacement of wood pellets would be needed.

Structural and Optical Properties of ZnS Thin Films Fabricated by Using RF Sputtering and Rapid Thermal Annealing Process for Buffer Layer in Thin Film Solar Cells (박막태양전지 버퍼층 적용을 위해 RF 스퍼터링 및 급속열처리 공정으로 제작한 황화아연 박막의 구조적 광학적 특성)

  • Park, Chan-Il;Jun, Young-Kil
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.4
    • /
    • pp.665-670
    • /
    • 2020
  • Buffer layer in CIGS thin-film solar cells improves energy conversion efficiency through band alignment between the absorption layer and the window layer. ZnS is a non-toxic II-VI compound semiconductor with direct-transition band gaps and n-conductivity as well as with excellent lattice matching for CIGS absorbent layers. In this study, the structural and optical properties of ZnS thin films, deposited by RF magnetron sputtering method and subsequently performed by the rapid thermal annealing treatment, were investigated for the buffer layer. The zincblende cubic structures along (111), (220), and (311) were shown in all specimens. The rapid thermal annealed specimens at the relatively low temperatures were polycrystalline structure with the wurtzite hexagonal structures along (002). Rapid thermal annealing at high temperatures changed the polycrystalline structure to the single crystal of the zincblende cubic structures. Through the chemical analysis, the zincblende cubic structure was obtained in the specimen with the ratio of Zn/S near stoichiometry. ZnS thin film showed the shifted absorption edge towards the lower wavelength as annealing temperature increased, and the mean optical transmittance in the visible light range increased to 80.40% under 500℃ conditions.

A Fuel Cell Generation Modeling and Interconnected Signal Analysis using PSCAD/EMTDC (연료전지 발전시스템의 PSCAD/EMTDC 모델링 및 계통연계에 따른 전력신호 분석에 관한 연구)

  • Choi, Sang-Yule;Park, Jee-Woong;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.21-30
    • /
    • 2008
  • The fuel cell generation convert fuel source, and gas directly to electricity in an electro-chemical process. Unlike traditional and conventional turbine engines, the process of fuel cell generation do not burn the fuel and run pistons or shafts, and it has not revolutionary machine, so have fewer efficiency losses, low emissions and no noisy moving parts. A high power density allows fuel cells to be relatively compact source of electric power, beneficial in application with space constraints. In this system, the fuel cell itself is nearly small-sized by other components of the system such as the fuel reformer and power inverter. So, the fuel cell energy's stationary fuel cells produce reliable electrical power for commercial and industrial companies as well as utilities. In this paper, a fuel cell system has been modeled using PSCAD/EMTDC to analyze its electric signals and characteristics. Also the power quality of the fuel cell system has been evaluated and the problems which can be occurred during its operation have been studied by modeling it more detailed. Particularly, we have placed great importance on its power quality and signal characteristics when it is connected with a power grid.

An Analysis of Single-person Households' Expenditure Pattern (1인가구의 품목별 소비지출 분석)

  • Park, Moon-Soo;Chong, Hogun;Kim, Hwa-Nyeon;Koh, Dae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.987-994
    • /
    • 2015
  • This study examines how single-person household expenditure patterns are different with respect to age and income groups using Tobit model. The expenditure data of the national household survey from 2006 to 2012 were used. The results show that income elasticities of all items are greater than 1 except for food & beverage, housing, water, electricity & gas, and Communication. Income elasticities are significantly different among consuming items. Additionally the income elasticities are also different between various age and income groups of single-person households. Therefore governments and businesses have to take this into account when devising their policies or strategies regarding single-person households. Especially, businesses need to adopt a strategy targeted at single-person households with high income and buying power such as unmarried professional people. As the number of single-person household increases the proportion of expenditures on necessities such as beverage, food, and energy is expected to decrease while that on services increases. Consequently policy responses are required to prepare for the expansion of service industries such as health, hospital, and housekeeping services.

Technical Trends of Hydrogen Manufacture, Storage and Transportation System for Fuel Cell Vehicle (연료전지자동차용 수소제조와 저장·운반기술동향)

  • Kil, Sang-Cheol;Hwang, Young-Gil
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.48-59
    • /
    • 2016
  • The earth has been warming due to $CO_2$ gas emissions from fossil fuel cars and a ship. So the hydrogen fuel cell vehicle(FCV) using hydrogen as a fossil fuel alternative energy is in the spotlight. Hyundai Motor Company of Korea and a car companies of the US, Japan, Germany is developing a FCV a competitive. Obtained hydrogen as a by-product of the coke plant, oil refineries, chemical plants of steel mill, coal is reacted with steam at high temperatures, methane gas, manufacture of high purity hydrogen Methane Steam Reforming and hydrogen detachable reforming method using the Pressure Swing Adsorption or Membrane Reforming technical or decomposition of water to produce electricity. Hydrogen is the electronic industry, metal and chemical industries, which are used as rocket fuel, etc. are used in factories, hospitals, home of the fuel Ene.Farm system or FCV. And a method of storing hydrogen is to store liquid hydrogen and a method for compressing normal hydrogen to the hydrogen container, by storing the latest hydride or Organic chemical hydride method is used to carry the hydrogen station. Korea is currently 13 hydrogen stations in place and in operation, plans to install a further 43 places.

A Study on Characteristics and Modeling of CMV by Grounding Methods of Transformer for ESS (ESS용 변압기의 접지방식에 의한 CMV 모델링 및 특성에 관한 연구)

  • Choi, Sung-Moon;Kim, Seung-Ho;Kim, Mi-Young;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.587-593
    • /
    • 2021
  • Since 2017, a total of 29 fire accidents have occurred in energy storage systems (ESSs) as of June 2020. The common mode voltage (CMV) is one of the electrical hazards that is assumed to be a cause of those fire accidents. Several cases of CMV that violate the allowable insulation level of a battery section are being reported in actual ESS operation sites with △-Y winding connections. Thus, this paper evaluates the characteristics of CMV. An ESS site was modeled with an AC grid, PCS, and battery sections using PSCAD/EMTDC software. As a result of a simulation based on the proposed model, it was confirmed that characteristics of CMV vary significantly and are similar to actual measurements, depending on the grounding method of the internal transformer for PCS. The insulation level of the battery section may be severely degraded as the value of CMV exceeds the rated voltage in case of a grounding connection. It was found that the value of CMV dramatically declines when the internal transformer for PCS is operated as non-grounding connection, so it meets the standard insulation level.

Scenario-based Vulnerability Assessment of Hydroelectric Power Plant (시나리오 기반 수력플랜트 설비의 취약성 평가)

  • Nam, Myeong Jun;Lee, Jae Young;Jung, Woo Young
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.9-21
    • /
    • 2021
  • Recently, the importance of eco-friendly power generation facility using renewable energy has newly appeared. Hydropower plant is a very important source of electricity generation and supply which is very important to secure safety because it is commonly connected with multi facility and operated on a large scale. In this study, a scenario-based analysis method was suggested to assess vulnerability of a penstock system caused by water hammer commonly occurred in the operation of hydropower plants. A hypothetical hydropower plant was used to demonstrate the applicability of a transient analysis model. In order to verify reliability of the model, the prediction of pressure behaviors were compared with the results of commercial model (SIMSEN) and measured data, then a real hydroelectric power plant was applied to develop all potential water hammer scenarios during the actual operation. The scenario-based simulation and vulnerability assessment for water hammer in the penstock system were performed with internal and external load conditions. The simulation results indicated that the vulnerability of a penstock system was varied with the operating conditions of hydropower facilities and significantly affected by load combination consisting of different load scenarios. The proposed numerical method could be an useful tool for the vulnerabilityty assessment of the hydropower plants due to water hammer.

Development of Intelligent Outlets for Real-Time Small Power Monitoring and Remote Control (실시간 소전력 감시 및 원격제어용 지능형 콘센트 개발)

  • Kyung-Jin Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.169-174
    • /
    • 2023
  • Currently, overall power usage is also increasing as power demand such as homes, offices, and factories increases. The increase in power use also raised interest in standby power as a change in awareness of energy saving appeared. Home and office devices are consuming power even in standby conditions. Accordingly, there is a growing need to reduce standby power, and it aims to have standby power of 1W or less. An intelligent outlet uses a near-field wireless network to connect to a home network and cut or reduce standby power of a lamp or appliance connected to an outlet. This research aims to develop a monitoring system and an intelligent outlet that can remotely monitor the amount of electricity used in a lighting lamp or a home appliance connected to an outlet using a short-range wireless network (Zigbee). Also, The intelligent outlet and monitoring system developed makes it possible for a user to easily cut off standby power by using a portable device. Intelligent outlets will not only reduce standby power but also be applicable to fire prevention systems. Devices that cut off standby power include intelligent outlets and standby power cutoff switches, so they will prevent short circuits and fires.