• 제목/요약/키워드: Electricity Energy

검색결과 1,998건 처리시간 0.026초

상수원수 수질변화에 따른 전오존 처리효과 및 경제성 평가 (Evaluation of Pre-ozone Treatment and Economic Efficiency as Changing Raw Water Quality)

  • 최동훈;박진식;문추연;이재용;류동춘;장성호;권기원;이수애
    • 한국환경과학회지
    • /
    • 제22권4호
    • /
    • pp.453-461
    • /
    • 2013
  • This study, changes in raw water quality is to indicate on the efficiency of ozone treatment of each pollutant as compared to derive the appropriate operating measures. The appropriate selection for injection rate of pre-ozone and did not inject pre-ozone assess changes in the water. When good water quality, you not injected of pre-ozone to evaluate the economic efficiency of electricity and put the most cost-effective ozone concentration were evaluated. Evaluation remove organic matter and chlorophyll-a concentration level in experiments with each factor of the water DOC> 2.5 mg/L, THMFP> 70 ${\mu}g/L$, Chl-a> 30 $mg/m^3$or less constant process, if you do not need to put pre-ozone showed little impact. It also does not put you in pre-ozone appropriate produce enough power rate savings was calculated as approximately 90 million won. Ability to remove organic materials and the ability to produce disinfection byproducts, and cost-effective decisions by considering the concentration of injection if pre-ozone 1 mg/L was investigated by the appropriate concentration of ozone injection.

선박용 디젤엔진의 배기가스 열회수 시스템 (I) - R245fa 및 Water 의 작동유체에 대한 에너지효율 비교 - (Exhaust-Gas Heat-Recovery System of Marine Diesel Engine (I) - Energy Efficiency Comparison for Working Fluids of R245fa and Water -)

  • 최병철;김영민
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.293-299
    • /
    • 2012
  • 대형 선박의 추진용 디젤엔진에서 버려지는 배기가스의 열을 회수하기 위한 랭킨사이클이 적용된 발전시스템에 대하여 R245fa 및 water 의 작동유체들에 따른 열역학적 효율 특성을 분석하였다. 그 이론적인 계산 결과로, 고정된 질량유량의 R245fa 에 대하여 터빈입구의 압력이 증가할수록 사이클, 시스템, 및 전체적 효율이 증가하였고, 사이클에 의해 발생되는 순동력도 증가하는 특성을 보였다. 반면, water 의 경우에는 R245fa 에 비하여 더 낮은 질량유량 및 터빈입구 압력의 비율에서 최대의 시스템 효율을 보였다. 또한 water 에 대하여 최적화된 사이클의 순출력, 시스템 효율, 및 전체적 효율의 값들은 R245fa 의 경우보다 더 크게 나타났다.

자동차용 연료전지 시스템의 가습모델과 열/물균형 유지방법 (Humidification model and heat/water balancing method of PEMFC system for automotive applications)

  • 정승훈;윤석호;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.339-344
    • /
    • 2005
  • A PEMFC system model for FCEV was constructed and simulated numerically to examine the heat/water flow of the system and air/fuel humidification process for various operation conditions (ambient pressure /temperature/humidity, operating temperature, power load). We modeled PEMFC stack which can generate maximum electricity of about 80 kW. This stack consists of 400 unit cells and each unit cell has $250cm^2$ reacting area. Uniform current density and uniform operating voltage per each cell was assumed. The results show the flow characteristics of heat and water at each component of PEMFC system in macro-scale. The capacity shortage of the radiator occurred when the ambient was hot $(over\;40^{\circ}C)$ and power level was high (over 50 kW). In spite of some heat release by evaporation of water in stack, heat unbalance reached to 20kW approximately in such a severe operating condition. This heat unbalance could be recovered by auxiliary radiators or high speed cooling fan with additional cost. In cold environment, the capacity of radiator exceeded the net heat generation to be released, which may cause a problem to drop the operating temperature of stack. We dealt with this problem by regulating mass flow rate of coolant and radiator fan speed. Finally, water balance was not easily broken when we retrieved condensed and/or unused water.

  • PDF

손실파라미터계산방법을 이용한 집광형태양광발전시스템 시뮬레이션 (Using the Loss parameter calculation method for the CPV system simulation)

  • 이강연;정병호;김지원
    • 한국융합학회논문지
    • /
    • 제8권8호
    • /
    • pp.17-26
    • /
    • 2017
  • 집광형태양광발전시스템은 집광형태양전지 셀, 모듈, PCS, 태양위치추적기, 시스템설비와 그에 따른 시스템주변창치들로 구성된다. 이러한 다양한 요소를 반영하여 시스템모델링이 이루어져 집광형태양광발전시스템에 대한 분석과 모델링방법이 적용되어야 한다. 본 논문에서 제안된 이러한 다양한 요소를 반영하여 최적의 CPV 시스템 시뮬레이션을 제안하여 집광형태양광발전시스템 모델링과 에너지의 발생분석에 대한 최적 설계가 이루어지도록 모델링에 중점 두어 설계하였다. 손실 파라미터 계산 방법에 관한 일반화된 집광형태양광발전시스템의 계산된 시뮬레이션 결과는 높은 신뢰성과 안정성을 갖는 집광형태양광발전시스템의 최적의 설계가 가능하다. 손실 파라미터 계산 방법은 CPV 시스템 설계의 경제적 분석을 위한 시뮬레이션 및 다양한 데이터 활용을 위한 시뮬레이션방법을 활용할 수 있다.

자중조절형 해상풍력 지지구조 개념설계 및 부유이송 현장시험 (Conceptual Design of Self-Weighing Support Structure for Offshore Wind Turbines and Self-Floating Field Test)

  • 김석태;김동현;강금석;정민욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.631-638
    • /
    • 2016
  • 해상풍력발전은 경관 및 소음 등의 문제 및 풍황자원 고갈로 인한 사업부지 확보가 어려운 육상풍력발전의 대안으로 주목받고 있다. 해상풍력은 해상에 풍력터빈을 세우기 때문에 경관 훼손이나 소음으로 인한 민원발생이 적고 상대적으로 풍황자원이 풍부하기 때문에 발전생산성이 높다. 그러나 육상풍력에 비해 해상풍력은 설치비가 높아 경제성이 떨어뜨리는 요인으로 작용한다. 이러한 높은 설치비는 해상작업에 필요한 대형장비의 대여기간과 높은 대여료에서 기인하는데, 본 논문에서는 대형 해상장비의 사용을 최소화하여 설치할 수 있는 해상풍력 지지구조의 개념설계를 수행하였다.

보일러-터빈 설비에 대한 기준모델 추종 퍼지 제어시스템의 설계 (A Design of Reference Model Following Fuzzy Control System for Boiler-Turbine Equipment)

  • 정호성;황창선;황현준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권4호
    • /
    • pp.82-91
    • /
    • 1997
  • I보일러-터빈 설비는 화력발전소의 주전원설비 내지 자가발전설비로서 보일러는 연료를 연소시켜 그 열을 수관내의 물에 전달하여 필요한 증기를 얻는 설비이고, 터빈은 보일러에서 보내온 고온, 고압의 증기를 팽창시켜 기계적 에너지로 변환하여 그 에너지로 발전기를 회전하여 전기를 얻는 장치이다. 보일러-터빈 설비는 전기적 출력과 드럼내의 증기압 및 수위를 적절히 조절함으로써 발전소의 안정된 운전을 도모하고 발전용 연료의 절감 및 이를 통한 공해 저감을 이루어야 할 필요가 있다. 본 논문에서는 이런 보일러-터빈 설비에 대한 제어시스템을 설계하는 한 방법으로서 기준모델 추종형 퍼지 시스템을 제안한다. 보일러-터빈 설비는 다변수 비선형 시스템으로서 일반적인 제어시스템 구성이 힘들지만, 오버슈트가 없으며 속응성이 좋은 기준모델을 선정하고 이 기준모델을 추종하도록 하는데 일반적인 1입력-1출력 퍼지제어기만을 적용하여도 기준신호에 대한 추종성 및 외란제거 능력 그리고 모델링 오차에 대한 강인성까지 나타내는 제어시스템의 설계가 가능하게 되었다. 따라서 전원설비로서의 보일러-터빈 설비에 대한 효율적인 제어시스템 설계방법으로 활용될 수 있을 것이다.

  • PDF

토크전단형 고력볼트의 토크계수 변동에 따른 체결축력 확보방안에 관한 연구 (A Study on the Secure Plan of Clamping Force according to the Variation of Torque-Coefficient in Torque-Shear High Strength Bolts)

  • 이현주;나환선;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.8-16
    • /
    • 2014
  • Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.

연료전지 자동차용 이산화탄소 열펌프 시스템의 성능평가 (Performance Evaluation of a $CO_2$ Heat Pump System for Fuel Cell Vehicles)

  • 김성철;박종철;김민수;원종필
    • 한국자동차공학회논문집
    • /
    • 제16권1호
    • /
    • pp.37-44
    • /
    • 2008
  • The global warming potential (GWP) of $CO_2$ refrigerant is 1/1300 times lower than that of R134a. Furthermore, the size and weight of the automotive heat pump system can decrease because $CO_2$ operates at high pressure with significantly higher discharge temperature and larger temperature change. The presented $CO_2$ heat pump system was designed for both cooling and heating in fuel cell vehicles. In this study, the performance characteristics of the heat pump system were analyzed for heating, and results for performance were provided for operating conditions when using recovered heat from the stack coolant. The performance of the heat pump system with heater core was compared with that of the conventional heating system with heater core and that of the heat pump system without heater core, and thus the heat pump system with heater core showed the best performance among the selected heating systems. On the other hand, the heating performance of two different types of coolant/air heat pump systems with heater core was compared each other at various coolant inlet temperatures. Furthermore, to use exhausted thermal energy through the radiator, experiments were carried out by changing the arrangement of a radiator and an outdoor evaporator, and quantified the heating effectiveness.

기상자료와 냉난방 실측자료를 이용한 열부하 추정과 예측: 다계층모형의 활용 (Estimation and Prediction of the Heat Load Profile Using Weather and Heating/Cooling Data : An Application of the Multilevel Model)

  • 문춘걸;김수덕
    • 자원ㆍ환경경제연구
    • /
    • 제16권4호
    • /
    • pp.803-832
    • /
    • 2007
  • 새로운 접단에너지 사업에 대한 경제성 평가와 기존 집단에너지 시설의 최적운용을 위해서는 적어도 시간대 단위로 계측된 세부용도별 에너지 부하패턴에 관한 정보가 필수적이다. 본 연구에서는 기상자료와 냉난방 실측자료를 활용하여 열부하를 추정 예측하기 위하여 다계층모형을 선태하였다. 다계층모형은 수집한 자료의 패널자료 특성을 유연하게 모형화할 수 있는 이점이 있다. 다계층모형을 일대일의 대응관계에 있는 선형혼합효과모형으로 변환한 후 패널 FGLS(연산가능한 일반화최소자승추정법)를 적용하여 세부용도별로 열부하모형을 추정하였다. 추정된 부하모형은 온도, 습도, 시간대, 요일, 설날연휴/추석연휴 등 법정공휴일 특성, 난방면적/냉방면적이 열에너지사용량에 미치는 영향을 고려하고 있다. 지면을 고려하여 본 논문에서는 가정용 난방부하모형의 추정치와 난방부하곡선의 예측치에 제한하여 실증결과를 설명하고 있다.

  • PDF

열회수장치의 열교환 파이프배치형식별 열교환 성능 비교(II) (Comparision of Heat Exchanging Performance Depending on Different Arrangement of Heat Exchanging Pipe (II))

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.281-285
    • /
    • 2001
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared for the comparison of heat recovery performance; AB-type(control unit) is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types(C-type and D-type) modified from the control unit are different in the aspects of airflow direction(U-turn airflow) and pipe arrangement. The results are summarized as follows; 1. In the case of Type-AB, when considering the initial cost and current electricity fee required for system operation, it is expected that one or two years at most would be enough to return the whole cost invested. 2. Type-C and Type-D, basically different with Type-AB in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than $25\;m^{3}/min$. Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This is assumed to be that air flow resistance in high air capacity reduces the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate in Type-C and Type-D were improved by about 5% and 13%, respectively. 3. Desirable blower capacity for these heat recovery units experimented are expected to be about $25\;m^{3}/min$, and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it is recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., are required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

  • PDF