• 제목/요약/키워드: Electrical switching

검색결과 4,078건 처리시간 0.028초

3상 승압형 AC/DC 컨버터의 고역율과 스위칭 손실 저감을 위한 공진 PWM 스위칭 기법에 관한 연구 (Study on Resonant PWM Switching Technique for $3{\phi}$ Boost AC/DC Converter with High Power Factor and Less Switching Loss)

  • 이은규;노영남;김병진;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.541-543
    • /
    • 1997
  • In this paper, a proposed resonant PWM switching technique makes the boost AC/DC converter to high input power factor and less switching loss. Also, the switching control scheme is used which minimize harmonic components employing novel PWM technique. In addition, an employment of resonant circuit for switching makes zero current switching(ZCS) and zero voltage switching(ZVS) for control switches without switching losses. The result shows that high power factor is still for varying load and switching loss is very low.

  • PDF

Zero-Voltage-Switching을 이용한 고주파 인버어터 (High Frequency Inverter using Zero-Voltage-Switching)

  • 심광열;문창수;김동희;김용훈;유동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1133-1135
    • /
    • 1992
  • This paper describes high frequency inverter using zero voltage switching(ZVS). The ZVS operation is achieved to reduce the switching stress and switching loss under high speed switching. The proposed circuit configuration and performance are discussed. Its operation characteristics are evaluated through computer-aided simulation.

  • PDF

스위치 손실 감소를 위한 단상 3레벨 NPC 인버터의 새로운 스위칭 방법 (A New Switching Method for Reducing switch loss of Single-phase three-level NPC inverter)

  • 이승주;이준석;이교범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.268-275
    • /
    • 2015
  • This paper proposes a method of switching to improve power loss for the single-phase three-level NPC inverter. The conventional switching methods, which are called as the bipolar and unipolar switching methods, are used for single phase inverters using three-level topology. However, these switching method have disadvantage in the power loss. Because all of the switch are operated. To reduce the power loss of the three-level NPC inverter, clamp switching method is introduced in this paper. This way, one of the lag is fixed that switching loss is reduced. This paper analyzes and compares power losses of unipolar method and clamp method. The validity of the power loss analysis is verified through the simulation and experimental results.

Balanced Buck-Boost Switching Converter to Reduce Common-Mode Conducted Noise

  • Shoyama Masahito;Ohba Masashi;Ninomiya Tamotsu
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.212-216
    • /
    • 2001
  • Because conventional switching converters have been usually using unbalanced circuit topologies, parasitic capacitance between the drain/collector of an active switch and the frame ground through its heat sink may generate the common-mode conducted noise. We have proposed a balanced switching converter circuit, which is an effective way to reduce the common-mode conducted noise. As an example, a boost converter version of the balanced switching converter was presented and the mechanism of the common-mode noise reduction was explained using equivalent circuits. This paper extends the concept of the balanced switching converter circuit and presents a buck-boost converter version of the balanced switching converter. The feature of common-mode noise reduction is confirmed by experimental results and the mechanism of the common-mode noise reduction is explained using equivalent circuits.

  • PDF

THE ROBUST CONTROLLER DESIGN FOR UNCERTAIN MULTIVARIABLE SYSTEM USING SWITCHING DYNAMICS

  • Park, Gwi-Tae;Kuo, Chun-Ping;Kim, Dong-Sik;Lim, Sung-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.924-930
    • /
    • 1989
  • This paper presents the design of simple robust controller for a class of uncertain multivariable systems. We introduce switching dynamics instead of switching logics unlike variable structure control scheme. Also, we can construct the continuous control law from this switching dynamics and consequently remove the chattering motion. The dynamic equations of the range-space of a switching surface matrix C and uniform ultimate boundedness in the presence of parameter uncertainties are described mathematically.

  • PDF

저압용차단기 전원 개폐시 개인용 PC에 미치는 영향 분석 (Analysis of Effect on Personnel Computer in case of turning off Power supply of Circuit Breaker for Low Voltage)

  • 길형준;송길목;김영석;김종민
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.124-129
    • /
    • 2014
  • This paper describes the analysis of the effect on personnel computer in case of turning off power supply of main breaker in general electrical installation. In order to analyze the effect on personnel computer in case of turning off the power supply of main breaker, the switching impulse generator has been designed and fabricated which makes it possible to evaluate the effect on electrical product by switching impulse. The switching impulse tests were carried out for personnel computer according to applied voltage and number of switching impulse. As a consequence, switching impulse had not a significant influence on personnel computer in this study. The varistor of power input section functions as a protection of switching impulse as well as lightning impulse. The results will be used to related organization, and electrical product manufacturer, and residents.

손실을 최소화한 새로운 영전류 스위칭 방식의 PWM 컨버터 (New Zero-Current-Switching PWM Converters with Low Switching Loss)

  • 마근수;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1193-1195
    • /
    • 2000
  • In conventional zero-current-switching(ZCS) PWM converters, the switching loss, stress and noise can't be minimized because they adopt auxiliary switches operated in hard-switching. In this paper, new ZCS-PWM converters of which auxiliary switches always operate with soft-switching are proposed. Therefore, the proposed ZCS-PWM converters are most suitable for systems requiring high-power density. The characteristics of these converters are verified by results of simulation.

  • PDF

Cascaded H-bridge PWM 멀티레벨인버터의 스위칭 손실 저감을 위한 효율적인 스위칭 패턴 (Efficient Switching Pattern to Decrease Switching Losses in Cascaded H-bridge PWM Multilevel Inverter)

  • 정보창;김선필;김광수;박성준;강필순
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.502-509
    • /
    • 2013
  • It presents an efficient switching pattern, which expects a reduction of switching losses in a cascaded H-bridge PWM multilevel inverter. By the proposed switching scheme, the lower H-bridge module operates at low frequency of 60[Hz] because it assigns to transfer most load power. The upper H-bridge module operates at high frequency of PWM switching to improve THD of output voltage. The proposed switching pattern applies to cascaded H-bridge multilevel inverter with PD, APOD, bipolar, and unipolar switching methods. By computer-aided simulations, we verify the validity of the proposed switching scheme. Finally, we prove that the proposed PD and APOD switching patterns are better than those of the conventional one in efficiency.

센서를 이용한 선로전환기 전환력 측정의 현장 적용성 연구 (A Study on the Field Application of Switching Power Measurement by using Sensor in Electrical Point Machine)

  • 이종현;김용규;박재영
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.1130-1136
    • /
    • 2015
  • Most equipments which are used to measure the switching power of the turnout depend on imports. As the data is limited to the measurements of the switching power, it is said that the equipment is insufficient to check the errors of the turnout and the electrical point machine, and set up the data for operating and maintenance. We studied not only measurements of the switching power of all turnout being used in domestic but also the development of the turnout performance total analysis equipment which can measure switching time, voltage, and current etc. at the same time. Considering that switching power of the turnout is the most basic element to check the irregularities of the turnout, in this paper, we analyzed the irregularities of the turnout through correlation between switching power of the turnout, voltage, and current of the electrical point machine. Also we performed test in commercial railway line where the turnout of MJ81 type and NS type was installed. And it is said that the test results can be used as basic technologies for ICT based real-time diagnosis and monitoring of the turnout.

넓은 범위 입력전압에 소프트 스위칭이 가능한 양방향 인터리브드 DC-DC 컨버터 (Bidirectional Soft Switching Three-Phase Interleaved DC-DC Converter for a Wide Input Voltage Range)

  • 최우진;이교범;정규범
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.313-320
    • /
    • 2015
  • This study deals with a bidirectional interleaved soft switching DC-DC converter for a wide range of input voltages. The proposed converter operates in complementary switching with the purpose of inductor size reduction and zero-voltage switching (ZVS) operation. The current ripple related to complementary switching is minimized by three-phase interleaved operation. The main characteristics of the proposed topology are its soft-switching method of operation and its simple structure. The soft-switching operation and the system efficiency of the proposed converter are verified by experimental results.