• Title/Summary/Keyword: Electrical response

Search Result 3,682, Processing Time 0.03 seconds

DC Inrush Current Suppression Method during the transient response of Inverter in MMC HVDC System. (HVDC용 MMC의 인버터 초기 기동시 발생되는 직류단 돌입전류 억제 기법)

  • Jung, Woong;Park, Chang-Hwan;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.23-24
    • /
    • 2016
  • 본 논문은 모듈러 멀티레벨 컨버터(MMC)에서 인버터로 사용할 경우 스위칭이 시작할 때, 과도상태에서 발생하는 돌입전류로 인해 시스템 제어의 불안전성을 야기한다. 따라서 이 전류를 저감하기 위해 제안한 등가회로 모델링, 제어를 MATLAB 시뮬레이션을 통하여 돌입전류에 대한 논의와 크기 저감을 확인하고자 한다.

  • PDF

A Performance Improvement of Exciter Control System of Synchronous Generator using Transient Response Compensator (과도 응답 보상기를 가지는 동기발전기의 고성능 여자 제어시스템)

  • Lee, Dong-Hee;Wang, Huijun;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.82-89
    • /
    • 2007
  • AVR(Automatic Voltage Regulator) of exciter control system in AC generator controls voltage and current according to load and terminal voltage variations in order to remain at the bus voltage. The output characteristics of main generator is dependent on the control performance of AVR. This paper presents the PWM type exciter system with transient response compensator for robust control of load variations. Additional transient response compensator generates compensation signal for load variation. So the proposed excitation control system has fast dynamic response in transient period and can control terminal voltage constantly. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

On Benchmarking of Real-time Mechanisms in Various Periodic Tasks for Real-time Embedded Linux (실시간 임베디드 리눅스에서 다양한 주기적 타스크의 실시간 메커니즘 성능 분석)

  • Koh, Jae-Hwan;Choi, Byoung-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • It is a real-time system that the system correctness depends not only on the correctness of the logical result of the computation but also on the result delivery time. Real-time Operating System (RTOS) is a software that manages the time of a microprocessor to ensure that the most important code runs first so that it is a good building block to design the real-time system. The real-time performance is achieved by using real-time mechanisms through data communication and synchronization of inter-task communication (ITC) between tasks. Therefore, test on the response time of real-time mechanisms is a good measure to predict the performance of real-time systems. This paper aims to analysis the response characteristics of real-time mechanisms in kernel space for real-time embedded Linux: RTAI and Xenomai. The performance evaluations of real-time mechanism depending on the changes of task periods are conducted. Test metrics are jitter of periodic tasks and response time of real-time mechanisms including semaphore, real-time FIFO, Mailbox and Message queue. The periodicity of tasks is relatively consistent for Xenomai but RTAI reveals smaller jitter as an average result. As for real-time mechanisms, semaphore and message transfer mechanism of Xenomai has a superior response to estimate deterministic real-time task execution. But real-time FIFO in RTAI shows faster response. The results are promising to estimate deterministic real-time task execution in implementing real-time systems using real-time embedded Linux.

Seismic Response Prediction of a Structure Using Experimental Modal Parameters from Impact Tests (충격시험에 의한 실험모드특성을 이용한 구조물의 지진응답 예측)

  • Cho, Sung-Gook;Joe, Yang-Hee;So, Gi-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • An in-cabinet response spectrum should be generated to perform the seismic qualification of devices and instruments mounted inside safety-related electrical equipment installed in nuclear power plants. The response spectrum is available by obtaining accurate seismic responses at the device mounting location of the cabinet. The dynamic behavior of most of electrical equipment may not be easily analyzed due to their complex mass and stiffness distributions. Considering these facts, this study proposes a procedure to estimate the seismic responses of a structure by a combination of a test and subsequent analysis. This technique firstly constructs the modal equations of the structure by using the experiment modal parameters obtained from the impact test. Then the seismic responses of the structure may be calculated by a mode superposition method. A simple steel frame structure was fabricated as a specimen for the validation of the proposed method. The seismic responses of the specimen were estimated by using the proposed technique and compared with the measurements obtained from the shaking table tests. The study results show that it is possible to accurately estimate the seismic response of the structure by using the experimental modal parameters obtained from the impact test.

Classification of Indoor Environmental Gases Using Temperature Modulation (열적 변화를 이용한 실내환경 가스의 분류)

  • Choi, Nak-Jin;Shim, Chang-Hyun;Song, Gap-Duk;Joo, Byung-Su;Lee, Yun-Su;Lee, Sang-Moon;Lee, Duk-Dong;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.279-285
    • /
    • 2002
  • Two $SnO_2$ based sensing films(pure $SnO_2$ and $SnO_2$/Pt) and a Pt thin film for temperature sensor on an alumina substrate were designed and fabricated for classifying the indoor environmental gases. By controlling the heating power in the shape of trapezoid, unique four sensing response curves created from both $SnO_2$ film and $SnO_2$/Pt film. Then, various parameters were extracted from sensing response curves and carried out principal component analysis(PCA). The results confirm that a sensor array with the proposed operating mode was extremely effective in classifying indoor environmental gases such as $CO_2$, $C_3H_8$, $C_4H_{10}$.

Gas Sensing Properties of Pt Doped Fe2O3 Nanoparticles Fabricated by Sol-Gel Method (Sol-Gel 방법을 이용하여 제작된 Pt이 첨가된 Fe2O3 나노 입자의 가스 감지 특성)

  • Jang, Min-Hyung;Lim, Yooseong;Choi, Seung-Il;Park, Ji-In;Hwang, Namgyung;Yi, Moonsuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.5
    • /
    • pp.288-293
    • /
    • 2017
  • $Fe_2O_3$ is one of the most important metal oxides for gas sensing applications because of its low cost and high stability. It is well-known that the shape, size, and phase of $Fe_2O_3$ have a significant influence on its sensing properties. Many reports are available in the literature on the use of $Fe_2O_3$-based sensors for detecting gases, such as $NO_2$, $NH_3$, $H_2S$, $H_2$, and CO. In this paper, we investigated the gas-sensing performance of a Pt-doped ${\varepsilon}$-phase $Fe_2O_3$ gas sensor. Pt-doped $Fe_2O_3$ nanoparticles were synthesized by a Sol-Gel method. Platinum, known as a catalytic material, was used for improving gas-sensing performance in this research. The gas-response measurement at $300^{\circ}C$ showed that $Fe_2O_3$ gas sensors doped with 3%Pt are selective for $NO_2$ gas and exhibita maximum response of 21.23%. The gas-sensing properties proved that $Fe_2O_3$ could be used as a gas sensor for nitrogen dioxide.

Delamination evaluation on basalt FRP composite pipe by electrical potential change

  • Altabey, Wael A.
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.5
    • /
    • pp.515-528
    • /
    • 2017
  • Since composite structures are widely used in structural engineering, delamination in such structures is an important issue of research. Delamination is one of a principal cause of failure in composites. In This study the electrical potential (EP) technique is applied to detect and locate delamination in basalt fiber reinforced polymer (FRP) laminate composite pipe by using electrical capacitance sensor (ECS). The proposed EP method is able to identify and localize hidden delamination inside composite layers without overlapping with other method data accumulated to achieve an overall identification of the delamination location/size in a composite, with high accuracy, easy and low-cost. Twelve electrodes are mounted on the outer surface of the pipe. Afterwards, the delamination is introduced into between the three layers (0º/90º/0º)s laminates pipe, split into twelve scenarios. The dielectric properties change in basalt FRP pipe is measured before and after delamination occurred using arrays of electrical contacts and the variation in capacitance values, capacitance change and node potential distribution are analyzed. Using these changes in electrical potential due to delamination, a finite element simulation model for delamination location/size detection is generated by ANSYS and MATLAB, which are combined to simulate sensor characteristic. Response surfaces method (RSM) are adopted as a tool for solving inverse problems to estimate delamination location/size from the measured electrical potential changes of all segments between electrodes. The results show good convergence between the finite element model (FEM) and estimated results. Also the results indicate that the proposed method successfully assesses the delamination location/size for basalt FRP laminate composite pipes. The illustrated results are in excellent agreement with the experimental results available in the literature, thus validating the accuracy and reliability of the proposed technique.

Design of Low Order Cascade Controller to Reduce the Effects of Its Zeros (제어기 영점의 영향을 감소시키는 종속형 저차 제어기의 설계)

  • Kim, Young-Chol;Kim, Jae-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1048-1057
    • /
    • 2008
  • This paper represents a design method for PID or low-order controllers cascaded with a linear plant in the unit feedback system where it is required to meet the given time response specifications such as overshoot and settling time. This problem is difficult to solve because the zeros of the controller appear in the numerator of the overall system and thus those zeros may make the time response design difficult. In this paper, we propose a new approach based on the partial model matching and the so called K-polynomial. The partial matching problem is formulated to an optimization problem in which a quadratic function of coefficient errors between a target model and the resulting closed loop system is minimized. For the sake of satisfying the closed loop stability, a set of quadratic constraints associated with the cost function is introduced. As a result, the controller designed meets both time response requirements and the closed loop stability, if any. It is shown through several examples that the present method can be easily applied to these problems.

An Analysis of Particle-clumping Phenomena of a Charged Particle-type Reflective Electronic Display

  • Kim, Young-Cho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.212-214
    • /
    • 2012
  • Both the electrically positive and negative particles in a cell of quick response-liquid powder display (QR-LPD) are surrounded by conductive electrodes on the upper and lower substrate and the dielectric materials of the barrier ribs. Particles in a cell are attached to or detached from the other materials by image force, electric field, Coulomb's force, and Van der Waals' force. Through these forces, the moving particles form an image but induce clumping phenomena. Particles having a large kinetic energy by a large q/m value crash into the opposite electrode with high speed at a large driving voltage and quickly lose electrically charged material. As a result, these particles are clumped and degrade panel performance. The clumped particles in a cell are observed by microscopic photographs and ascertained by a response time. When the bias voltage is increased to 0.68-0.76 $V/{\mu}m$, particle clumping occurs abruptly and the response time increases sharply. This particle clumping is similarly observed after the number of driving times at the driving voltage (0.42-0.64 $V/{\mu}m$).

Response Characteristic Analysis using Modeling of Propulsion System for 8200 Electric Locomotive (8200호대 전기기관차 추진시스템 모델링을 이용한 응답특성분석)

  • Jung, No-Geon;Chang, Chin-Young;Yun, Cha-Jung;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1640-1646
    • /
    • 2013
  • Conventional power conversion unit that is a major part of the propulsion system has applied GTO thyristor as a switching semiconductor device of main circuit since introduction of the 8200 electric locomotive. But problem that quick maintenance is difficult and its cost is increasing occurs because major components of the power conversion unit are slowly discontinued. To solve these, in this paper, it was analyzed the response characteristic of the propulsion system modeling of the 8200 electric locomotive using IGBT which is applied recently to ensure propulsion control technology. As results of response for a Propulsion system modeling, it show that a power conversion unit is controlled by PLL(Phase-locked loop) and SVPWM(Space Voltage PWM) respectively.