• Title/Summary/Keyword: Electrical response

Search Result 3,682, Processing Time 0.035 seconds

Optimal Controller Design for Single-Phase PFC Rectifiers Using SPEA Multi-Objective Optimization

  • Amirahmadi, Ahmadreza;Dastfan, Ali;Rafiei, Mohammadreza
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.104-112
    • /
    • 2012
  • In this paper a new method for the design of a simple PI controller is presented and it has been applied in the control of a Boost based PFC rectifier. The Strength Pareto evolutionary algorithm, which is based on the Pareto Optimality concept, used in Game theory literature is implemented as a multi-objective optimization approach to gain a good transient response and a high quality input current. In the proposed method, the input current harmonics and the dynamic response have been assumed as objective functions, while the PI controller's gains of the PFC rectifier (Kpi, Tpi) are design variables. The proposed algorithm generates a set of optimal gains called a Pareto Set corresponding to a Pareto Front, which is a set of optimal results for the objective functions. All of the Pareto Front points are optimum, but according to the design priority objective function, each one can be selected. Simulation and experimental results are presented to prove the superiority of the proposed design methodology over other methods.

Fast Response and Versatility in Digitally Controlled Rolling Mill DC Drives (고성능, 다기능의 Rolling Mill DC전동기 제어 시스템 개발)

  • Kim, K.H.;Cho, W.J.;Park, I.Y.;Song, S.H.;Park, K.W.;Choi, C.H.;Sul, S.K.;Ji, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.595-602
    • /
    • 1994
  • PERISTOR-3000 loaded with 32 bit DSP(Digital Signal Processor) is a technically advanced versatile dc motor controller in applications with very high requirements for rapid response, control accuracy and reliability. The current controller of PERISTOR-3000 is of the predictive type and gives fast control with both discontinuous and continuous current compared to the conventional PI current control. The speed controller gain is compensated to improve response behavior. PERISTOR-3000 communicates with its host computer, POSTAR-3200, or any IBM or compatible PC and can be controlled. Dedicated monitoring system for MMI is introduced.

  • PDF

Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions (그리드/연계선 사고 시 풍력발전단지의 응동 분석)

  • Lee, Hye-Won;Kim, Yeon-Hee;Zheng, Tai-Ying;Lee, Sang-Cheol;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.

Fast Single-Phase All Digital Phase-Locked Loop for Grid Synchronization under Distorted Grid Conditions

  • Zhang, Peiyong;Fang, Haixia;Li, Yike;Feng, Chenhui
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1523-1535
    • /
    • 2018
  • High-performance Phase-Locked Loops (PLLs) are critical for grid synchronization in grid-tied power electronic applications. In this paper, a new single-phase All Digital Phase-Locked Loop (ADPLL) is proposed. It features fast transient response and good robustness under distorted grid conditions. It is designed for Field Programmable Gate Array (FPGA) implementation. As a result, a high sampling frequency of 1MHz can be obtained. In addition, a new OSG is adopted to track the power frequency, improve the harmonic rejection and remove the dc offset. Unlike previous methods, it avoids extra feedback loop, which results in an enlarged system bandwidth, enhanced stability and improved dynamic performance. In this case, a new parameter optimization method with consideration of loop delay is employed to achieve a fast dynamic response and guarantee accuracy. The Phase Detector (PD) and Voltage Controlled Oscillator (VCO) are realized by a Coordinate Rotation Digital Computer (CORDIC) algorithm and a Direct Digital Synthesis (DDS) block, respectively. The whole PLL system is finally produced on a FPGA. A theoretical analysis and experiments under various distorted grid conditions, including voltage sag, phase jump, frequency step, harmonics distortion, dc offset and combined disturbances, are also presented to verify the fast dynamic response and good robustness of the ADPLL.

A Hybrid Active Queue Management for Stability and Fast Adaptation

  • Joo Chang-Hee;Bahk Sae-Woong;Lumetta Steven S.
    • Journal of Communications and Networks
    • /
    • v.8 no.1
    • /
    • pp.93-105
    • /
    • 2006
  • The domination of the Internet by TCP-based services has spawned many efforts to provide high network utilization with low loss and delay in a simple and scalable manner. Active queue management (AQM) algorithms attempt to achieve these goals by regulating queues at bottleneck links to provide useful feedback to TCP sources. While many AQM algorithms have been proposed, most suffer from instability, require careful configuration of nonintuitive control parameters, or are not practical because of slow response to dynamic traffic changes. In this paper, we propose a new AQM algorithm, hybrid random early detection (HRED), that combines the more effective elements of recent algorithms with a random early detection (RED) core. HRED maps instantaneous queue length to a drop probability, automatically adjusting the slope and intercept of the mapping function to account for changes in traffic load and to keep queue length within the desired operating range. We demonstrate that straightforward selection of HRED parameters results in stable operation under steady load and rapid adaptation to changes in load. Simulation and implementation tests confirm this stability, and indicate that overall performances of HRED are substantially better than those of earlier AQM algorithms. Finally, HRED control parameters provide several intuitive approaches to trading between required memory, queue stability, and response time.

A study on the baseline load estimation method for microgrid energy trading (마이크로그리드 전력 거래를 위한 기준부하 추정 방법에 대한 연구)

  • Wi, Young-Min
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.324-329
    • /
    • 2018
  • As the environment of power systems changes, the demand and necessity for new electrical energy market are increasing. Especially, efforts to increase the efficiency of electric energy use by using demand response programs are being studied constantly in advanced countries and it is operated as a real market. This paper presents a study on the baseline load estimation required in the new power market, such as demand response, P2P electricity trading etc. The proposed method estimates the baeline load through analysis of the load pattern and verifies the effectiveness of the proposed method using actual data.

EPC method for delamination assessment of basalt FRP pipe: electrodes number effect

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.1
    • /
    • pp.69-84
    • /
    • 2017
  • Delamination is the most common failure mode in layered composite materials. The author have found that the electrical potential change (EPC) technique using response surfaces method is very effective in assessment delamination in basalt fiber reinforced polymer (FRP) laminate composite pipe by using electrical capacitance sensor (ECS). In the present study, the effect of the electrodes number on the method is investigated using FEM analyses for delamination location/size detection by ANSYS and MATLAB, which are combined to simulate sensor characteristic. Three cases of electrodes number are analyzed here are eight, twelve and sixteen electrodes, afterwards, the delamination is introduced into between the three layers [$0^{\circ}/90^{\circ}/0^{\circ}$]s laminates pipe, split into eight, twelve and sixteen scenarios for cases of eight, twelve and sixteen electrodes respectively. Response surfaces are adopted as a tool for solving inverse problems to estimate delamination location/size from the measured EPC of all segments between electrodes. As a result, it was revealed that the estimation performances of delamination location/size depends on the electrodes number. For ECS, the high number of electrodes is required to obtain high estimation performances of delamination location/size. The illustrated results are in excellent agreement with solutions available in the literature, thus validating the accuracy and reliability of the proposed technique.

Methods for Adding Demand Response Capability to a Thermostatically Controlled Load with an Existing On-off Controller

  • Jin, Young Gyu;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.755-765
    • /
    • 2015
  • A thermostatically controlled load (TCL) can be one of the most appropriate resources for demand response (DR) in a smart grid environment. DR capability can be effectively implemented in a TCL with various intelligent control methods. However, because traditional on-off control is still a commonly used method in a TCL, it is useful to develop a method for adding DR capability to the TCL with an existing on-off controller. As a specific realization of supervisory control for implementing DR capability in the TCL, two methods are proposed - a method involving the changing of a set point and a method involving the paralleling of an identified system without delay. The proposed methods are analyzed through the simulations with an electric heater for different power consumption levels in the on-state. Considerable cost benefit can be achieved with the proposed methods when compared with the case without DR. In addition, the observations suggest that a medium power consumption level, instead of the maximum power, in the on-state should be used for consistently obtaining the cost benefit without severe temperature deviation from the specified temperature range for DR.

A study on speed and Position of scanner Using PID controller (PID제어기를 이용한 스캐너의 속도 및 위치 제어)

  • Yeo, Bong-Hyeon;Chung, Yong-Chang;Hong, Chul-Ho;Kim, Jae-Wook;Kim, Mun-Su
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3178-3180
    • /
    • 2000
  • In this thesis, a controller which is appropriate for uses of scanner with small error and high speed response is proposed. Recently the application field of scanner is on increase. In case of applying to laser marking, the error of scanner has bad effect to quality. Also it can make difficulties in applying laser show that makes images, unless the high speed response is not realized. For these reasons, a controller that can adjust error and response is need. Because scanner must respond to step input that is put between a few millisecond and hundreds of microsecond with small revolution angle ranges, it is advantageous to have small inertia and large torque. First, the property of scanner is treated, and then using Op-amp and passive components and applying feedback compensation PID controller to design, the effects by controller coefficients are introduced.

  • PDF

New Target Transfer Functions with No Overshoot

  • Yang, Dae--Jeong;Kim, Young-Chol
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.14-20
    • /
    • 2001
  • To design a controller based on the pole placement method, it is necessary to obtain either a target transfer function or a desired characteristic equation which results in the closed-loop response. Specially, a step response in which no overshoot occurs in highly desirable in many applications. In this paper, we present two new present two new prototypes of Type I target transfer functions whose step responses have an overshoot of less than 0.1%. One prototype is obtained by Taylor's approximation of a Gaussian function. It is, however, observed that the response delays increase with increasing order, while the rise times are nearly constant. The other prototype is a modification of the first prototype, so that their transfer function coefficients have particular values in terms of specific parameters ${\gamma}$i and $\tau$ (see section 2). The second prototype gives very useful properties in which step responses are almost the same shape, irrespective of the order. It, also, has no overshoot. Some other properties of the prototypes and an application example are given.

  • PDF