• 제목/요약/키워드: Electrical response

검색결과 3,677건 처리시간 0.035초

수요관리사업자가 수요반응 전력시장에 미치는 영향 분석 (Analysis on Demand Response Aggregator in Electricity Market)

  • 이광호
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1181-1186
    • /
    • 2017
  • The purpose of Demand Response is to reduce the cost of excessive resources and equipment by spontaneous load reductions at peak loads. Having enough power consumers participating in these schemes is key to achieving the goal. Demand Response Aggregator (DRA) is responsible for recruiting demand resources and managing them to participate in reducing the load. DRAs change the price elasticity of demand functions by providing incentives to demand response, thereby affecting price formation in the electricity market. In this paper, this process is modeled to analyze the relationship between DRA's strategic bidding and market outcomes and load reductions. It analyzes the results by applying to competition between DRAs, competition between DR and Gencos, and coexistence of DR load and non-DR load. It is noteworthy that we have found a phenomenon called the Balloon Effect.

수요반응자원이 포함된 전력시장의 쿠르노 경쟁모형 해석 (Analysis of Cournot Model of Electricity Market with Demand Response)

  • 이광호
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.16-22
    • /
    • 2017
  • In order to reduce costs of electricity energy at periods of peak demand, there has been an exponential interest in Demand Response (DR). This paper discusses the effect on the participants' behavior in response to DR. Under the assumption of perfect competition, the equilibrium point of the electricity market with DR is derived by modeling a DR curve, which is suitable for microeconomic analysis. Cournot model is used to analyze the electricity market of imperfect competition that includes strategic behavior of the generation companies. Strategic behavior with DR makes it harder to compute equilibrium point due to the non-differential function of payoff distribution. This paper presents a solution method for achieving the equilibrium point using the best response function of the strategic players. The effect of DR on the electricity market is illustrated using a test system.

속응 여자식 초전도 발전기 열전자 차폐막의 전자 차폐 특성 해석 (Magnetic Shielding Effects of the Electrothermal Shield of a Superconducting Generator with Quick-Response Excitation)

  • 이홍배;배동진;김석환;한성진;차귀수;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.49-52
    • /
    • 1990
  • In this paper, we proposed a new electrothermal shield model with slits for the purpose of applying to the Superconducting Generator with Quick-Response Excitation. Via experimental and finite element analysis, we compared the magnetic shielding effects of the proposed electrothermal shield model with the conventional one. It is considered that he proposed models meet the needs for the electrothermal shields of the Superconducting Generator with Quick-Response Excitation.

  • PDF

Statistical Modeling of Pretilt Angle Control using Ion-beam Alignment on Nitrogen Doped Diamond-like Carbon Thin Film

  • Kang, Hee-Jin;Lee, Jung-Hwan;Han, Jung-Min;Yun, Il-Gu;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.297-300
    • /
    • 2006
  • The response surface modeling of the pretilt angle control using ion-beam (IB) alignment on nitrogen doped diamond-like carbon (NDLC) thin film layer is investigated. This modeling is used to analyze the variation of the pretilt angle under various process conditions. IB exposure angle and IB exposure time are considered as input factors. The analysis of variance technique is settled to analyze the statistical significance, and effect plots are also investigated to examine the relationships between the process parameters and the response. The model can allow us to reliably predict the pretilt angle with respect to the varying process conditions.

Fault Response of a DFIG-based Offshore Wind Power Plant Taking into Account the Wake Effect

  • Kim, Jinho;Lee, Jinsik;Suh, Yongsug;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.827-834
    • /
    • 2014
  • In order to meet the low voltage ride-through requirement in a grid code, a wind power plant (WPP) has to stay connected to a grid, supporting the voltage recovery for a grid fault. To do this, a plant-level controller as well as a wind generator (WG) controller is essential. The dynamic response of a WPP should be analyzed in order to design a plant-level controller. The dynamic response of a WPP for a grid fault is the collective response of all WGs, which depends on the wind speed approaching the WG. Thus, the dynamic response of a WPP should be analyzed by taking the wake effect into consideration, because different wind speeds at WGs will result in different responses of the WPP. This paper analyzes the response of a doubly fed induction generator (DFIG)-based offshore WPP with a grid fault taking into account the wake effect. To obtain the approaching wind speed of a WG in a WPP, we considered the cumulative impact of multiple shadowing and the effect of the wind direction. The voltage, reactive power, and active power at the point of common coupling of a 100 MW DFIG-based offshore WPP were analyzed during and after a grid fault under various wind and fault conditions using an EMTP-RV simulator. The results clearly demonstrate that not considering the wake effect leads to significantly different results, particularly for the reactive power and active power, which could potentially lead to incorrect conclusions and / or control schemes for a WPP.

터빈 블레이드 모델링을 통한 터빈 발전기 축 시스템의 기계적 토크 응답 분석 (Analysis of Turbine-Generator Shaft System Mechanical Torque Response based on Turbine Blade Modeling)

  • 박지경;정세진;김철환
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1269-1275
    • /
    • 2015
  • Turbine-generator torsional response is caused by interaction between electrical transient air-gap torque and mechanical characteristics of turbine-generator shafts. There are various factors that affects torsional interaction such as fault, circuit breaker switching and generator mal-synchronizing, etc. Fortunately, we can easily simulate above torsional interaction phenomena by using ElectroMagnetic Transient Program (EMTP). However, conventional EMTP shows the incomplete response of super- synchronous torsional mode since it does not consider turbine blade section. Therefore, in this paper, we introduced mechanical-electrical analogy for detailed modeling of turbine-generator shaft system including low pressure turbine blade section. In addition, we derived the natural frequencies of modeled turbine-generator shaft system including turbine blade section and analyzed the characteristics of mechanical torque response at shaft coupling and turbine blade root area according to power system balanced/unbalanced faults.

청각 자극용 전기자극기 개발 (Development of Electrical Stimulator for Auditory Stimulation)

  • 허승덕;정동근;김리석;김광년;강명구;김재룡;김기련
    • 음성과학
    • /
    • 제11권3호
    • /
    • pp.201-211
    • /
    • 2004
  • This paper introduces a development of an electrical stimulator for auditory stimulation. The electrical stimulator is useful in neurotological diagnosis, audiological evaluation, candidate selection for cochlear implantation, optimal device selection and decision making of MAP strategy for severe-to-profound hearing impaired persons. The development was based on sound parameters of auditory brainstem responses and auditory electrophysiological characteristic such as effective firing of auditory nerve and recording evoked potentials during refractory period of neuron. Besides pulse parameter could adjustable by programming for more varied electrical stimulation evoked response audiometry. Using the electrical stimulator, electrical square pulse was applied to promontory, and electrically evoked auditory brainstem response and electrically middle latency response were successfully recorded in cats.

  • PDF

Statistical Modeling of Pretilt Angle Control on the Homogeneous Polyimide Surface as a Function of Rubbing Strength and Baking Temperature

  • Kang Hee-Jin;Lee Jung-Hwan;Hwang Jeoung-Yeon;Yun Il-Gu;Seo Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.81-86
    • /
    • 2006
  • In this paper, the response surface modeling of the control of the pretilt angle in the nematic liquid crystal on the homogeneous polyimide surface with different surface treatment is investigated. The pretilt angle is one of the main factors to determine the alignment of the liquid crystal display. The pretilt angle is measured to analyze the variation of the characteristics on the various process conditions. The rubbing strength and the hard baking temperature are considered as input factors. After the design of experiments is performed, the process model is then explored using the response surface methodology. The analysis of variance is used to analyze the statistical significance and the effect plots are also investigated to examine the relationship between the process parameters and the response.

Thermal Response Analysis of a Low Thermal Drift Three-axis Accelerometer for High Temperature Environments

  • Ishida Makoto;Lee Kyung Il;Takao Hidekuni;Sawada Kazuaki;Seo Hee Don
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.872-875
    • /
    • 2004
  • In this paper, thermal response analysis of a temperature controlled three-axis accelerometer for high temperature environments with integrated micro-heaters and temperature sensors is investigated with finite element method (FEM) program, ANSYS and infrared thermal measurement systems. And availability to application fields from a viewpoint about short thermal response time is discussed. In this paper, the time of three-axis accelerometer for high temperatures becoming $300^{\circ}C$ by integrated micro-heaters and temperature sensors to reduce thermal drift characteristics was analyzed as a thermal response time of this device. The simulated thermal response time (time until SOI piezoresistors actually becomes $300^{\circ}C$) of three-axis accelerometer for high temperatures with ANSYS is about 0.6s, and measured result with infrared temperature measurement systems is about 0.64s. Experimental results using infrared thermal measurement systems agreed well with these theoretical results.

  • PDF

직류 전동기의 유한 시간 정정 응답 제어 (Speed Control of D.C Motor based on Deadbeat Response)

  • 김영석;유완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.371-374
    • /
    • 1990
  • This paper presents the speed control of dc motor based on deadbeat response. The deadbeat response is that the output reaches the final value in the minimum possible settling time and stays there. This results demonstrate that the output reaches final value in one sampling time for the unsaturated region, and in one sampling time after getting free from the saturation state for the saturated region.

  • PDF