• 제목/요약/키워드: Electrical resistance wire

검색결과 145건 처리시간 0.035초

12kV급 다이오드의 패키징 구조에 따른 방열 특성 연구 (Heat Dissipation Analysis of 12kV Diode by the Packaging Structure)

  • 김남균;김상철;방욱;송근호;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1092-1095
    • /
    • 2001
  • Steady state thermal analysis has been done by a finite element method in a diode of 12kV blocking voltage. The diode was fabricated by soldering ten pieces of 1200V diodes in series, capping a dummy wafer at the far end of diode series, and finally wire bonded for building anode and cathode terminal. In order to achieve high voltage and reliability, the edge of each diode was beveled and passivated by resin with a thickness of 25${\mu}$m. It was assumed that the generated heat which is mainly by the on-state voltage drop, 9V for 12kV diode, is dissipated by way of the conduction through diodes layers to bonding wire and of the convection at the surface of passivating resin. It was predicted by the thermal analysis that the temperature rise of a pn junction of the 12kV diode can reach at the range of 16∼34$^{\circ}C$ under the given boundary conditions. The thickness and thermal conductivity(0.3∼3W/m-K) of the passivating resin did little effect to lower thermal resistance of the diode. As the length of the bonding wire increased, which means the distance of heat conduction path became longer, the thermal resistance increased considerably. The thermal analysis results imply that the generated heat of the diode is dissipated mainly by the conduction through the route of diode-dummy wafer-bonding wire, which suggests to minimize the length of the wire for the lowest thermal resistance.

  • PDF

자수 도전사(傳導絲) 기반의 유아체온 센싱 시스템 설계 연구 (A Design of Infant's Body Temperature Sensing System Based on Embroidery Textile Conductive Wire)

  • 송하영;이강휘;이정환
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.862-867
    • /
    • 2016
  • In this study, the embroidery textile conductive wire of conductive yarn was designed into the wearable integrated clothing for sensing the infant's body temperature. To develop a high quality of the stable fiber-based textile conductive wire, firstly the five types of conductive yarns were twisted or covering polyester yarns and the coated conductive fiber with silver(Ag) or iron(Fe). As a result of comparative conductivity in conductive yarns of yarn processing, the 250 denier of conductive yarns with $0.74{\Omega}$/1~5cm were proposed and used for the integrated embroidery textile conductive wire for sensing. During experiments using the proposed embroidery textile conductive wire, measured resistance of thermistor according to the body temperature was correctly delivered to amplifier module, and showed feasible reliability of temperature sensing. As a wearable application, conductive yarns which takes forms of embroidery textile conductive wire would seems to be reliable as a conductive wire and could be replaced by the conductive metal wires.

대체 보조전극을 이용한 접지저항 측정값 비교 (Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

해빙 시스템을 이용한 전차선 온도 특성에 관한 연구 (Temperature Analysis of Overhead Contact line Using De-icing System)

  • 박영;권삼영;정호성;박현준;조용현;김주락;안병립;원우식;이주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.601-602
    • /
    • 2005
  • In the cold and temperate regions of Korea the icing and ice coats on 25 kV overhead contact wire during winter is a very serious problem. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should be performed just before train operation to avoid the formation of another ice layer. This paper presents temperature analysis of the de-icing system which could be applied to the overhead contact wire of railways.

  • PDF

전기저항 측정기법을 이용한 오염물질 누출감지시스템의 개발: II. 현장모형시험을 통한 매립지에의 적용성 평가 (Development of Contaminant Leakage Detection System Using Electrical Resistance Measurement: ll. Evaluation of Applicability for Landfill Site by Field Model Tests)

  • 오명학;이주형;박준범;김형석;강우식
    • 한국지반공학회논문집
    • /
    • 제17권6호
    • /
    • pp.225-233
    • /
    • 2001
  • 본 논문에서는 격자망식 전선배치에 의한 침출수 누출감지시스템을 개발하기 위하여 현장모형시험을 통하여 적용성을 평가하였으며, 전기회로시험을 통하여 격자망 전선 배치에서 발생하는 전기회로적 효과를 파악하고자 하였다. 침출수는 전기저항을 감소시키기 때문에 누출지점에서는 다른 지점에 비해 낮은 전기저항값을 나타내었다. 따라서, 전기저항을 측정하는 본 누출감지시스템에 의하여 임의 지점에서 발생하는 침출수의 누출 감지가 가능하였으며, 평면적 분포도를 통하여 누출위치의 파악이 가능하였다. 전기저항이 감소된 지점과 동일한 전선상에 위치한 다른 센서에 서의 측정값도 약간 감소하는 경향을 나타내었으나, 이는 저항이 작은 곳으로 전류의 흐름이 발생하는 전기회로적 효과로 설명할 수 있었다.

  • PDF

YBCO Coated Conductor의 과전류 특성해석 (Analysis of Over-current Characteristics in YBCO Coated Conductor)

  • 이찬주;남관우;강형구;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

가공지선이 연결된 송전철탑의 탑각저항 측정에 관한 연구 (A Study on the Measurement of Footing Resistance of Transmission Towers with Overhead Grounding wires)

  • 이원교;최종기;이영우;최인혁;김경철
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.61-64
    • /
    • 2010
  • Footing Resistance of a 154 kV transmission towers in korea is commonly required to be less than 15 ohm to avoid lightning back-flashover accident. The periodic measurement of Footing Resistance is important to verify that the grounding performance of the towers has been maintained good. Towers are electrically connected in parallel with overhead grounding wire, therefore footing resistance of each tower will be measured after disconnecting the overhead ground wires from the towers. however, In this paper, three direct measurement methods of footing resistance are presented. There are very useful methods without disconnecting overhead ground wires from the tower under measurement. They are compared in KEPCO 154 kV transmission towers. The experimental results describe performances of them.

백금박막 측온저항체 온도센서의 개발 (The Development of Platinum Thin Film RTD Temperature Sensors)

  • 노상수;최영규;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.152-155
    • /
    • 1996
  • Platinum thin films were deposited on $Al_2$O$_3$substrate by DC magnetron sputtering for RTD(Resistance Thermometer Devices) temperature sensors. We made Pt resistance pattern on $Al_2$O$_3$substrate by lift-off method and fabricated Pt-RTD temperature sensors by using W-wire, silver epoxy and SOG(spin-on-glass). In the temperature range of 25~40$0^{\circ}C$, we investigated TCR(temperature coefficient of resistance) and resistance ratio of Pt-RTD temperature sensors. TCR values were increased with increasing the annealing temperature, time and the thickness of Pt thin films. Resistance values were varied lineally within the range of measurement temperature. At annealing temperature of 100$0^{\circ}C$, annealing time of 240min and thin film thickness of 1${\mu}{\textrm}{m}$, we obtained Pt-RDT TCR value of 3825ppm/$^{\circ}C$ closed to the Pt bulk value.

  • PDF

직류배전시스템에서 피뢰기 및 가공지선 접지간격 변경에 따른 뇌과전압 해석 (Lightning Overvoltage Analysis According to Interval of Arrester and Overhead Grounding Wire in DC Distribution System)

  • 안천용;이종범;김용갑
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.474-481
    • /
    • 2013
  • It is anticipated that AC distribution system can be replaced by DC distribution system in the near future because of the operation of various distributed source or microgrid system. However DC distribution system replacing 22.9kV AC distribution line is not sufficiently studied still. This paper describes lightning overvoltage analysis among many research fields should be studied to realize DC overhead distribution systems. DC distribution system is modeled using EMTP and overvoltage is analyzed according to interval of arrestor location, earth interval of overhead grounding wire and grounding resistance. It is evaluated that analysis results can be effectively used to design of future DC distribution system.