• Title/Summary/Keyword: Electrical resistance wire

Search Result 145, Processing Time 0.029 seconds

The Formation of Pt-Co Alloy Thin Films for RTD Temperature Sensors with Wide Temperature Ranges (광대역 측온저항체 온도센서용 Pt-CO 합금박막의 형성)

  • 김서연;노상수;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.335-338
    • /
    • 1997
  • Platinum-Cobalt alloy thin films were deposited on A1$_2$O$_3$substrate by magnetron cosputtering for RTD temperature sensors with wide temperature ranges. We made Pt-Co alloy resistance patterns on the A1$_2$O$_3$substrate by lift-off method and fabricated Pt-Co alley RTD temperature sensors by using Pt-wire, Pt-paste. We investigated the physical and electrical characteristics of theme films under various conditions, input power, working vacuum, annealing temperature and time, and also after annealing these films. The resistivity and sheet resistivity of these films were decreased with increasing the annealing temperature. At input power of Pt : 4.4 W/cm$^2$, Co : 6.91 W/cm$^2$, working vacuum of 10 mTorr and annealing conditions of 800$^{\circ}C$ and 60 min, the resistivity and sheet resistivity of Pt-Co thin films was 15${\mu}$$\Omega$$.$cm and 0.5$\Omega$/ , respectively, and the TCR value of Pt-Co alloy thin films with thickness of 3000${\AA}$ was 3740ppm/$^{\circ}C$ in the temperature range of 25∼600$^{\circ}C$. These results indicate that Pt-Co alloy thin films hove potentiality for the RTD with wide temperature ranges.

  • PDF

An Improvement of Digital Distance Relaying Algorithm on Underground Transmission Cables (지중송전케이블룡 디지털 거리계전 알고리즘 개선)

  • Ha, Che-Ung;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.12
    • /
    • pp.595-601
    • /
    • 2000
  • This paper describes the improvement method of distance relaying algorithm for the underground transmission cables. Distance relaying algorithms have been mainly developing to protect the overhead transmission lines than the underground cables. If the cable systems are directly protected using distance relaying algorithm developed for overhead line without any improvement, there will be really occurred many misoperation in cable systems, because the cable systems consist of the conductor, the sheath, several grounding method, cable cover protection units(CCPUs), and grounding wire. Accordingly, the complicated phenomena are occurred, if there is a fault in cable systems. Therefore, to develope a correct distance relaying algorithm, such cable characteristics should be taken into account. This paper presents the process to improve distance relaying algorithm which is now used. REal cable system was selected to establish modeling in EMTP and ATP Draw. It was discovered through the detailed simulation during the fault that the large error existed between impedance measured at the relay point and real impedance is due to the resistance of grounding wire in each grounding method. And also compensation factor obtained by the simulation is proposed in this paper. It is proved that the factor proposed can fairly improve the accuracy of impedance at the relay point. It is evaluated that the protective ability will be really much improved, if the algorithm proposed in this paper is applied for cable systems of utility.

  • PDF

Experimental Investigations Into Low Current Steady State Arcs In A Dual-Airflow Model Interrupter

  • Shin, Young-June;Cho, Yun-Ok;Kim, Jin-Gi;Lee, Jeong-Rim
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.961-965
    • /
    • 1992
  • It is well-known that shock waves frequently occur inside the nozzle of the interrupter, and that they play important roles in the arc interruption. A model interrupter with two-dimensional dual-airflow nozzles was used for this experiment. The arc was ignited with 1.4 mil copper wire stretched between the electrodes which were spaced out 56 mm. The arc current of 60 to 230 A was achieved by adjusting the external resistance from 5.5 to 1.6 ohms. The arc tests have been conducted for investigating the air arc characteristics, and the effects of shock waves and nozzle pressure ratios on the arc voltage, the arc resistance, the arc power, and average electric field. The results of these tests have been analyzed to provide insights into the arc characteristics for gas circuit breakers. The average electric field is represented by the function of the arc current to show the negative E-I characteristic explicitly. The effects of shock waves and nozzle pressure ratios are shown to be significant for a circuit breaker performance.

  • PDF

Microstructure and Strength of the Microjoined Electrode for the Lamp of the LCD Backlight Unit (TFT-LCD 백라이트 유닛(BLU) 램프용 전극 미세 접합부의 강도 및 미세조직)

  • Kim, Gwang-Soo;Kim, Sang-Duck
    • Korean Journal of Materials Research
    • /
    • v.19 no.1
    • /
    • pp.7-12
    • /
    • 2009
  • TFT-LCD is the most popular type of flat display panel in the information technology field. The back light unit is a main part of the structure of a TFT-LCD panel. Occasionally, studies have shown that failures of the CCFL of the BLU occur due to the poor weld characteristics of these materials. The aim of this study was to prepare some technical data and to characterize a microjoined electrode for the CCFL. Microstructure examinations, microhardness measurements, resistance measurements and microtensile tests of the microjoined electrode were carried out. The result indicates that a large amount of grain coarsening exists in the heat-affected zone (HAZ) of the weld between the cup and the pin. This grain coarsening of the HAZ between the cup and pin is caused by the welding cycle, which may have an influence on the lowest microhardness values. Fracturing of the microjoined electrode also occurred at the HAZ close to the cup between the weld holding the cup and the pin. Additionally, no specific changes of the electrical resistance among the cup, pin, and lead wire themselves or in the microjoined electrode were observed.

Temperature Measurement System for Refrigerated Vehicle (냉동차량을 위한 온도 측정 시스템)

  • Lim, Yong-Jin;Kim, Jung-Hwan;Lim, Joon-hong
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.159-163
    • /
    • 2019
  • The food service industry has been grown due to improvement of living standards. In addition, the demand for frozen food delivery is increasing day by day at online/offline and the refrigerated vehicles are used in most of these food distributions. One of the most important factors in a refrigerated car is to measure the temperature accurately. Conventional temperature recording systems are generally connected directly to temperature sensor modules. Since the temperature data are transmitted to the temperature recorder by using the electric wire, there is a disadvantage that the resistance error must be compensated according to the cable length. In this paper, we propose a method to correct errors due to cable resistance using digital processing and CAN (Controller Area Network) communication. We use PT-1000 platinum sensor to increase the accuracy of the temperature measurement.

Electrical and thermal properties of polyamideimide-colloid silica nanohybrid for magnetic enameled wire

  • Han, S.W.;Kang, D.P.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.428-432
    • /
    • 2012
  • Polyamidimide (PAI)-colloidal silica (CS) nanohybrid films were synthesized by an advanced sol-gel process. The synthesized PAI-CS hybrid films have a uniform and stable chemical bonding and there is no interfacial defects observed by TEM. The thermal degradation ratio of PAI-CS (10 wt%) hybrid films is delayed by 100 ℃ compared with pure PAI sample determined by on set temperature range in TGA. The dielectric constant of PAI-CS (10 wt%) hybrid films decreases with increasing CS content up to about 5 wt% but increases at higher CS content, which is not explained simply by effective medium therories (EMT). The duration time of PAI-CS (10 wt%) hybrid coil is 38 sec, which is very longer than that of pure PAI coil sample. The PAI-CS (10 wt%) hybrid film has a higher breakdown voltage resistance than the pure PAI film at surge environment and exhibits superior heat resistance. The PAI-CS (10 wt%) sample shows the advanced and stable thermal emission properties in transformer module compared with the pure PAI sample. This result illustrates that the advanced thermal conductivity and expansion properties of PAI-CS sample in the case of appropriate sol-gel processes brings the stable thermal emission in transformer system. Therefore, new PAI-CS hybrid samples with such stable thermal emission properties are expected to be used as a high functional coating application in ET, IT and electric power products.

On Atmospheres for Firing the Thick Film Coper Conductors (Thick Film Copper Conductor 의 소결과 소성 분위기)

  • Lee, Joon
    • Applied Chemistry for Engineering
    • /
    • v.2 no.3
    • /
    • pp.193-198
    • /
    • 1991
  • Thick film copper conductors are of considerable interest in thick film industries because of both the potential cost saving compared to the noble metal conductors and the favorable properties in electrical conductivity, solderability, solder leach resistance and wire bondability, However, formation of the excellent copper thick film is a lot complicated due to easily oxidizing property of copper at high temperature. In order to get favorable thick film copper conductor, hybrid microcircuit industry utilizes majorly three kinds of firing atmosphere, such as nitrogen atmosphere, reactive atmosphere and air atmosphere. The processes and the three atmospheres for firing thick film copper conductor were extensively reviewed in this article.

  • PDF

Propagation Characteristics of Surge Generated due to Internal Arc Discharge in Superconducting Magnet (초전도 마그네트 시스템 내부 아크방전에 의한 발생 서어지의 전파특성)

  • Choi, Byoung-Ju;Suehiro, Junya;Hara, Masanori
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1904-1906
    • /
    • 1996
  • Transient voltage distribution tests are carried out to evaluate effects of a high frequency oscillating voltage generated in a superconducting magnet as a result of the arc discharge extinction. Especially, the effects of temperature and conduction state of the magnet conductor on surge behavior are carefully investigated. Based on the results of simulation tests, it is shown that internal voltage waveforms are influenced by its transmission along the superconducting wire and reflection at the terminal and that attenuation process of the waveforms depends considerably on the conductor resistance which decreases with lowering the temperature.

  • PDF

Analysis of Current Distribution of HTSC Power Cable Considering Shield Layer (차폐층을 고려한 고온초전도 전력 케이블의 전류분류 해석)

  • Lee, Jong-Hwa;Lim, Sung-Hun;Ko, Seok-Cheol;Park, Chung-Ryul;Han, Byoung-Sung;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.12-14
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of import ant parameters in high-temperature superconduting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and AC loss. In this paper, the transport current distribution at conducting layers was investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer and compared with the case of without shield layer. The transport current distribution due to of the contact resistance and the pitch was improved in the case of HTSC power cable with shield layer from the analysis.

  • PDF

Thermal Stimulation System for Meridian point (경혈 열자극 시스템)

  • Yang, S.Y.;Huh, W.;Kim, J.K.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.223-226
    • /
    • 2001
  • In this paper, we devised electrical thermal stimulator for meridian point. The system consist of has four channel applicator, power controller and computer. The applicator consist of resistance wire heater and thermal sensor. A stimulation patterns are obtained from a real moxa combustion. The developed system does not make any smog, does not need moxa anymore, only need electricity.

  • PDF