• 제목/요약/키워드: Electrical resistance wire

검색결과 145건 처리시간 0.024초

결정질 태양전지 모듈 내부 저항의 Missmatch 분석 (The Analysis of missmatch with resistance on Si-PV module)

  • 지양근;공지현;강기환;유권종;원창섭;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, we test the electrical resistance of flat wire in the PV module. normally solar cell has two kind of flat wire(inter connection ribbon and bus bar ribbon). we found the phenomenon that has a unbalance with resistance when we make a wiling between of string. So, we measurement the resistance of flat wire each other. and analysis of missmatch with resistance between flat wires on PV module. next to survey of IR picture on missmatch flat wire samples for analyze of missmatch with current in the wire. and we perform IR test with solar cell that has a connection with flat wire for test the effect of missmatch resistance on solar cell. Finally we perform the Dark I-V test for survey of effect by the unbalance of resistance. By the result of Dark I-V test, the series resistance of existing connection sample is large more then innovated connection sample.

  • PDF

장력조정장치의 동작에 영향을 미치는 가선저항의 사례 (Examples of Trolley Wire Resistance Influential on The Movement of Tensioning Devices)

  • 윤용한;임금광;한양규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.886-892
    • /
    • 2007
  • This paper presents examples of trolley wire resistance influential on the movement of tensioning devices. Therefore, this study is on the examples of trolley wire resistance which keep tensioning devices from working properly to the expansion and contraction in accordance with temperature change of overhead trolley wire system such as messenger wire and contact wire. Trolley wire resistance interrupts the working of tensioning device and drops the capacity of trolley wire. Reduced trolley wire capacity lowers the performance of current collection and has a bad effect on electrical train operation. So it is desirable to reduce the factors increasing trolley wire resistance to the minimum from the designing and construction stage of overhead trolley wire system. This study will introduce this problem and suggest the solution.

  • PDF

Evaluation of AC Resistance in Litz Wire Planar Spiral Coils for Wireless Power Transfer

  • Wang, Xiaona;Sun, Pan;Deng, Qijun;Wang, Wengbin
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1268-1277
    • /
    • 2018
  • A relatively high operating frequency is required for efficient wireless power transfer (WPT). However, the alternating current (AC) resistance of coils increases sharply with operating frequency, which possibly degrades overall efficiency. Hence, the evaluation of coil AC resistance is critical in selecting operating frequency to achieve good efficiency. For a Litz wire coil, AC resistance is attributed to the magnetic field, which leads to the skin effect, the proximity effect, and the corresponding conductive resistance and inductive resistance in the coil. A numerical calculation method based on the Biot-Savart law is proposed to calculate magnetic field strength over strands in Litz wire planar spiral coils to evaluate their AC resistance. An optimized frequency can be found to achieve the maximum efficiency of a WPT system based on the predicted resistance. Sample coils are manufactured to verify the resistance analysis method. A prototype WPT system is set up to conduct the experiments. The experiments show that the proposed method can accurately predict the AC resistance of Litz wire planar spiral coils and the optimized operating frequency for maximum efficiency.

Position estimation and control of SMA actuators based on electrical resistance measurement

  • Song, Gangbing;Ma, Ning;Lee, Ho-Jun
    • Smart Structures and Systems
    • /
    • 제3권2호
    • /
    • pp.189-200
    • /
    • 2007
  • As a functional material, shape memory alloy (SMA) has attracted much attention and research effort to explore its unique properties and its applications in the past few decades. Some of its properties, in particular the electrical resistance (ER) based self-sensing property of SMA, have not been fully studied. Electrical resistance of an SMA wire varies during its phase transformation. This variation is an inherent property of the SMA wire, although it is highly nonlinear with hysteresis. The relationship between the displacement and the electrical resistance of an SMA wire is deterministic and repeatable to some degree, therefore enabling the self-sensing ability of the SMA. The potential of this self-sensing ability has not received sufficient exploration so far, and even the previous studies in literature lack generality. This paper concerns the utilization of the self-sensing property of a spring-biased Nickel-Titanium (Nitinol) SMA actuator for two applications: ER feedback position control of an SMA actuator without a position sensor, and estimation of the opening of a SMA actuated valve. The use of the self-sensing property eliminates the need for a position sensor, therefore reducing the cost and size of an SMA actuator assembly. Two experimental apparatuses are fabricated to facilitate the two proposed applications, respectively. Based on open-loop testing results, the curve fitting technique is used to represent the nonlinear relationships between the displacement and the electrical resistance of the two SMA wire actuators. Using the mathematical models of the two SMA actuators, respectively, a proportional plus derivative controller is designed for control of the SMA wire actuator using only electrical resistance feedback. Consequently, the opening of the SMA actuated valve can be estimated without using an extra sensor.

Resistance Increase Behavior of HTS Wire with Stabilizer Layer on Applied Over-currents

  • Du, Ho-Ik;Kim, Min-Ju;Doo, Seung-Gyu;Kim, Yong-Jin;Han, Byoung-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권2호
    • /
    • pp.62-65
    • /
    • 2009
  • YBCO-coated conductors, called "second-generation wires," show a remarkably greater increase in the amount or speed of their resistance than BSCCO wires when a quench occurs. This is probably because of the specific resistance at their stabilizer layer, which also affects their voltage grade. YBCO coated conductors with copper as a stabilizer layer have a voltage grade of 1.5-2 V/cm, and those with stainless steel as a stabilizer layer have a voltage grade of about 0.5-0.6 V/cm. The voltage grade of YBCO coated conductors is important in selecting and applying superconducting wires to power instruments later. In this study, two kinds of YBCO-coated conductors with different stabilizer layers and one kind of BSCCO wire were prepared. Among them, based on the YBCO coated conductors that had a stainless steel stabilizer layer with a low voltage grade, five kinds of experimental samples for joining were prepared with the remaining two kinds of wires. Using the prepared samples, the current application properties and the resistance increase in the flux-flow and the quench states of the single wire and the joined wires were compared.

YBCO 2G 선재간 접합 특성 연구 (Charateristics analysis of the joining of YBCO 2G HTS wire)

  • 장기성;박동근;양성은;안민철;조대호;김현규;;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.741-742
    • /
    • 2006
  • This paper deals with an efficient superconducting joint method between 2G high superconducting(HTS) wire, YBCO coated conductor(CC). Recently CC is one of the most promising superconducting wire due to high n-value and critical current independency from external magnetic field. It is expected to be used many superconducting application such as fault current limiter, persistent current system and cable etc. In most HTS applications, superconducting magnet is used, and it is necessary to joint between superconducting wire to fabricate superconducting magnet system. A CC tape used in this research consists of copper stabilizer, silver layer, YBCO layer, buffer and substrate. Direct joint using soldering method was inefficient due to resistance of copper, then copper lamination is removed by chemical etching method to reduce resistance between CC tapes. Jointed tapes were fabricated and tested. Transport current through jointed area and induced voltage were measured to characterize the I-V curve. Resistance between CC wire using chemical etching was compared with resistance of direct jointed tapes using soldering method in this paper.

  • PDF

티타늄합금의 와이어 방전가공과 연삭가공시 기계적 특성 (Mechanical Characteristics when Wire Electrical Discharge Machining and Surface Grinding for Titanium Alloy)

  • 김종업;왕덕현;김원일;이윤경
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.172-178
    • /
    • 2001
  • Titanium alloys have lightness, high strength and good corrosion resistant characteristics, and broadly used in manufacturing parts for military and aerospace industries. And these alloys also are recognized for organism materials comparatively and used as fixing ones in the human body. Nevertheless thess alloys have excellent properties such as corrosion resistance, heat resistance, and good tensile strength, it is difficult to machine by traditional methods because of high hardness and chemically activated property. So higher tool wear is expected when cutting by tools. Therefore, it is required nontraditional machining process. And the mechanical characteristics such as surface structure and shape, hardness and bending strength are studied for wire electrical discharge machined and surface ground titanium alloys for various heat-treated conditions.

  • PDF

Study on Current Limiting Characteristics of YBCO Thin-Film Wire with Insulation Layer

  • Doo, Seung-Gyu;Du, Ho-Ik;Jeon, An-Gyoon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권1호
    • /
    • pp.20-23
    • /
    • 2013
  • When applying superconducting wire to power machines, an investigation needs to be carried out on the characteristics of wire phase changes in connection with the insulating layer. This study examined trends in the increase of the wire's resistance and the characteristics of its recovery from quenching by a current-applied cycle at temperatures of 90 K, 180 K, and 250 K. The procedure was conducted based on the thickness and presence (or absence) of the insulating wire layers. To achieve this, YBCO thin-film wires with the same critical temperatures were prepared with copper and stainless steel stabilizing layers. At levels (-one, three, and five-), with superior performance, polyimide pressure-sensitive adhesive tape was attached to the wires at a very low temperature. The eight prepared test samples were wound around the linear frames. The wire's voltage and current created from the phase change characteristics were measured at the wire's prescribed temperature, using the four-point probe method. The wire's resistance and recovery characteristics were examined for each cycle at temperatures of 90 K, 180 K, and 250 K.

전기장판 열선 결함에 의한 전기화재 원인분석 (Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires)

  • 송재용;사승훈;남정우;김진표;조영진;오부열
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

낮은 저항과 열안정성을 가지는 Cu/Mn 합금저항의 전기적 특성 (Electrical Properties of Cu/Mn Alloy Resistor with Low Resistance and Thermal Stability)

  • 김은민;김성철;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제29권6호
    • /
    • pp.365-369
    • /
    • 2016
  • In this paper, we fabricated Cu/Mn alloy shunt resistor with low resistance and thermal stability for use of mobile electronic devices. We designed metal alloy composed of copper (Cu) and manganese (Mn) to embody in low resistance and low TCR which are conflict each other. Cu allows high electrical conductivity and Mn serves thermal stability in this Cu/Mn alloy system. We confirmed the elemental composition of the designed metal alloy system by using energy dispersive X-ray (EDX) analysis. We obtained low resistance below $10m{\Omega}$ and low temperature coefficient of resistance (TCR) below $100ppm/^{\circ}C$ from the designed Cu/Mn alloy resistor. And in order to minimize resistance change caused by alternative frequency on circuit, shape design of the metal alloy wire is performed by rolling process. Finally, we conclude that design of the metal alloy system was successfully done by alloying Cu and 3 wt% of Mn, and the Cu/Mn alloy resistor has low resistance and thermal stability.