• Title/Summary/Keyword: Electrical resistance measurement

Search Result 556, Processing Time 0.031 seconds

Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle (수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Moon, Hyun-Wook;Kim, Hyang-Kon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.

A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car (친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Moon, Hyun-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

Resistive displacement transducer enhanced measurement resolution by electrical line contact (선형 전기접촉으로 계측해상도가 향상된 저항성 변위센서)

  • Kim, Kyung-Ah;Choi, Seong-Su;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.263-269
    • /
    • 2007
  • Although variable resistance displacement transducer is widely applied for its technical simplicity, electrical point contact limits measurement resolution (precision). The present study introduced roller shaped structure for electrical line contact. Proto-type transducer was developed and measurement characteristics were compared with a commercialized product. When the displacement was varied with steps of 5 mm, 1 mm, and down to 0.1 mm, the correlation coefficient between resistance and displacement decreased lower than 0.9 in the commercialized product while the proto-type transducer maintained values higher than 0.99. Therefore, the measurement resolution was enhanced by approximately 10 times. Since manufacturing also seemed easier, the present results would enable more accurate and less expensive manufacturing of variable resistance displacement transducer.

A Study on the Measurement of the Winding Resistance Influences the Efficiency Evaluation of 3phase Induction Motors (삼상유도전동기 권선저항 측정이 효율 산출에 미치는 영향에 관한 연구)

  • Kang, Byung-Guk;Kim, Kwang-Min;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • 3phase induction motor consumes 40% of national electric power. so It is one of the most important electric device for the national power policy. The efficiency measurement is carried out by IEC standards. After the temperature rise test, It's difficult to measure the winding resistance immediately. because of inertia and power cut-off time. Therefore, IEC standards suggest the measurement time. But during the measurement time, the winding temperature cools down. It causes the value of winding resistance is variable. Several conditions which possibly occurred by the measurement time of IEC 60034-1 are suggested. and The efficiency evaluation of 3phase induction motors is carried out by IEC 60034-2-1 with the several conditions. As the results, we find out the winding resistance rapidly goes down within 15 sec. so It proves that the winding resistance should be measured within 15 sec. for the efficiency evaluating of 3phase induction motor.

Precise Resistivity Measurement Independent Of Contact Resistance Influence And Its Applications

  • Kim, Dae-Hyun;Ryu, Hye-Yeon;Ji, Hyun-Jin;Lee, Jae-Woo;Kim, Gyu-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.146-147
    • /
    • 2007
  • A universal four-point contact measurement method, has an advantage of non-existence of contact resistance, is demonstrated by the experiments with carbon nanotubes and ZnO nanowire. Ti/Au and Pt are tried to compare the influence of contact resistance between two different metals. These metals are selected to make Ohmic contact and Schottky contact originated from their different work functions. For precise experiments, Ti/Au and Pt are separately evaporated to form double 'four-point contact electrodes' on CNTs or ZnO, and the voltage-current characteristics are measured. This method can be applied to universal resistivity measurement for nanotubes and nanowires.

  • PDF

Monitoring Failure Behaviour of Pultruded CFRP Composites by Electrical Resistance Measurement

  • Mao, Yaqin;Yu, Yunhua;Wu, Dezhen;Yang, Xiaoping
    • Carbon letters
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2004
  • The failure behaviours of unidirectional pultruded carbon fiber reinforced polymer (CFRP) composites were monitored by the electrical resistance measurement during tensile loading, three-point-bending, interlaminar shear loading. The tensile failure behaviour of carbon fiber tows was also investigated by the electrical resistance measurement. Infrared thermography non-destructive evaluation was performed in real time during tensile test of CFRP composites to validate the change of microdamage in the materials. Experiment results demonstrated that the CFRP composites and carbon fiber tows were damaged by different damage mechinsms during tensile loading, for the CFRP composites, mainly being in the forms of matrix damage and the debonding between matrix and fibers, while for the carbon fiber tows, mainly being in the forms of fiber fracture. The correlation between the infrared thermographs and the change in the electrical resistance could be regarded as an evidence of the damage mechanisms of the CFRP composites. During three-point-bending loading, the main damage forms were the simultaneity fracture of matrix and fibers firstly, then matrix cracking and the debonding between matrix and fiber were carried out. This results can be shown in Fig. 9(a) and (b). During interlaminar shear loading, the change in the electrical resistance was related to the damage degree of interlaminar structure. Electrical resistance measurement was more sensitive to the damage behaviour of the CFRP composites than the stress/time curve.

  • PDF

A Study on the Measurement of Footing Resistance of Transmission Towers with Overhead Grounding wires (가공지선이 연결된 송전철탑의 탑각저항 측정에 관한 연구)

  • Lee, Won-Kyo;Choi, Jong-Kee;Lee, Young-Woo;Choi, In-Hyuk;Kim, Kyung-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.61-64
    • /
    • 2010
  • Footing Resistance of a 154 kV transmission towers in korea is commonly required to be less than 15 ohm to avoid lightning back-flashover accident. The periodic measurement of Footing Resistance is important to verify that the grounding performance of the towers has been maintained good. Towers are electrically connected in parallel with overhead grounding wire, therefore footing resistance of each tower will be measured after disconnecting the overhead ground wires from the towers. however, In this paper, three direct measurement methods of footing resistance are presented. There are very useful methods without disconnecting overhead ground wires from the tower under measurement. They are compared in KEPCO 154 kV transmission towers. The experimental results describe performances of them.

Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정값 비교)

  • Lee, Snag-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

A Study on the Measurement of Grounding Resistance Using the Fall-of-Potential Method (전위강하법을 이용한 접지저항 측정법 개선에 관한 연구)

  • Park, Duk-Yul;Wee, Won-Seok;Ryu, Bo-Hyuk;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1490-1492
    • /
    • 1999
  • This paper shows the accuracy of 61.8% rule which is based on the fall-of-potential method in field measurement of earth resistances, and proposes the measurement method which is applicable to the industries. This paper also finds the minimum distance to obtain the horizontal position in the earth resistance curves, and Proposes the standard form for measurement of earth resistance using the fall-of-Potential method.

  • PDF