• Title/Summary/Keyword: Electrical potential

Search Result 2,970, Processing Time 0.029 seconds

The Potential Interference between Ground Rod and Counterpoise (봉상 접지전극-수평매설 접지전극 상호간의 전위간섭)

  • Lee, Bok-Hee;Lee, Su-Bong;Jeong, Dong-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.351-354
    • /
    • 2006
  • This paper deals with the potential interferences between ground rod and counterpoise. The ground potential rise and coefficient of potential interference were measured by using the hemispherical water tank grounding simulator and calculated from CDEGS program as functions of the configuration and size of grounding electrodes and the distance between grounding electrodes. The ground potential un and potential interference coefficient strongly depend on the distance between grounding electrodes, the arrangement and size of grounding electrodes.

  • PDF

Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants (목본식물 형성층 전기저항에 영향을 주는 환경 요인)

  • Kim, Dong-Uk;Kim, Min-Soo;Lee, Bu-Yong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage (콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구)

  • Lee, Bomi;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.115-124
    • /
    • 2015
  • A modified electrical resistivity survey has been suggested and applied to a leakage detection problem of concrete barrage. We suggest the modified electrical resistivity methods using electrodes floating on the water and apply line current sources instead of conventional point current sources in order to facilitate simple analysis. In addition, the study introduced the following three variations of modified electrode array: Direct potential array, Parallel potential array and Cross potential array. These arrays were tested and investigated through numerical experiment, physical model experiment and geophysical field exploration in order to verify their applicability to the water leakage detection of a concrete barrage. When water leakage occurred, all kind of array operations demonstrated distinct changes of aspects of potential difference in graphs obtained by not only the numerical and physical model experiments but also geophysical field exploration. Therefore, this modified electrode arrays of electrical resistivity survey, which has been adapted to the concrete barrage, has been found to be a useful method to detect water leakage.

A Study on Electric Potential Change by Pulse Voltage Polarity in Liquid (펄스전압의 극성에 따른 액중 전위변화에 관한 연구)

  • Kim Jin-Gyu;Kim Hyung-Pyo;Park Young-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • This paper proposes the new type of an ion exchange water generator system. The system has an +/- ion exchange membrane located in center and a diagonal-interdigit type electrode applied to a pulsed power. This system is studied in the liquid for the oxidation/reduction potential and the dissolved oxygen concentration by the polarity effects. Consequently, as a diagonal-interdigit type electrode is installed in each side of device, the oxidation/reduction potential and dissolved oxygen concentration by polarity changes and electrical resistivity differences be observed. An ion concentration in the ion exchange water generator system is increased by dissolved oxygen generated from oxidation/reduction potential changes.

Non linear analysis of a functionally graded square plate with two smart layers as sensor and actuator under normal pressure

  • Arefi, M.;Rahimi, G.H.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.433-447
    • /
    • 2011
  • The present paper addresses the nonlinear response of a FG square plate with two smart layers as a sensor and actuator under pressure. Geometric nonlinearity was considered in the strain-displacement relation based on the Von-Karman assumption. All the mechanical and electrical properties except Poisson's ratio can vary continuously along the thickness of the plate based on a power function. Electric potential was assumed as a quadratic function along the thickness direction and trigonometric function along the planar coordinate. By evaluating the mechanical and electrical energy, the total energy equation can be minimized with respect to amplitude of displacements and electrical potential. The effect of non homogenous index was investigated on the responses of the system. Obtained results indicate that with increasing the non homogenous index, the displacements and electric potential tend to an asymptotic value. Displacements and electric potential can be presented in terms of planar coordinate system. A linear analysis was employed and then the achieved results are compared with those results that are obtained using the nonlinear analysis. The effect of the geometric nonlinearity is investigated by using the comparison between the linear and nonlinear results. Displacement-load and potential-load curves verified the necessity of a nonlinear analysis rather than a linear analysis. Improvement of the previous results (by the linear analysis) through employing a nonlinear analysis can be presented as novelty of this study.

Electrical Resistivity Tomography for Inverse Problem Using FEM (유한요소법을 이용한 전기 비저항 탐사법의 저항역산)

  • Lim, Sung-Ki;Kim, Min-Kyu;Jung, Hyun-Kyo;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.154-156
    • /
    • 1996
  • A new method for electric resistivity tomography(ERT) is developed for geophysical inverse problems by adapting the sensitivity analysis. The outputs of the potential electrodes are computed using two dimensional finite element method in the wave number space by Fourier transforming the governing equations. The resistance distribution in the region of interests, which makes the computed potential distribution coincide with the measured potential, is found by minimizing the objective function using an optimization method. In this process the sensitivity analysis is introduced in order to compute the derivatives of the objective function. And an adjoint variable method is used to save the computational efforts for sensitivity coefficients.

  • PDF

Analysis of the Electric Potential distribution and Evaluation of Electric Shock Risk in Bathtub (욕조에서의 전위분포 해석 및 전격재해 위험성 평가)

  • Kim, Chong-Min;Kim, Han-Sang;Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.37-40
    • /
    • 2006
  • This paper presents the evaluation electric shock risk In bath so that we made and designed a bathtub which is the same size in real public bath. and then we did an experiment, provided of electric leakage in various conditions so, we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. also we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply.

  • PDF

A Study on the Measurement of Grounding Resistance Using the Fall-of-Potential Method (전위강하법을 이용한 접지저항 측정법 개선에 관한 연구)

  • Park, Duk-Yul;Wee, Won-Seok;Ryu, Bo-Hyuk;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1490-1492
    • /
    • 1999
  • This paper shows the accuracy of 61.8% rule which is based on the fall-of-potential method in field measurement of earth resistances, and proposes the measurement method which is applicable to the industries. This paper also finds the minimum distance to obtain the horizontal position in the earth resistance curves, and Proposes the standard form for measurement of earth resistance using the fall-of-Potential method.

  • PDF

The Electronic Structure of Carbon Nanotubes with Finite Length : Tight Binding Theory

  • Moon, Won-Ha;Kim, Won-Woo;Hwang, Ho-Jung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.1
    • /
    • pp.23-29
    • /
    • 2002
  • The electronic properties of Carbon Nanotube(CNT) are currently the focus of considerable interest. In this paper, the electronic properties of finite length effect in CNT for the carbon nano-scale device is presented. To Calculate the electronic properties of CNT, Empirical potential method (the extended Brenner potential for C-Si-H) for carbon and Tight Binding molecular dynamic (TBMD) simulation are used. As a result of study, we have known that the value of the band gap decreases with increasing the length of the tube. The energy band gap of (6,6) armchair CNT have the ranges between 0.3 eV and 2.5 eV. Also, our results are in agreements with the result of the other computational techniques.

Study of Touch and Step Voltages with Grounding Grid Using Electrolytic Tank and Analysis Program

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kill, Gyung-Suk
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2010
  • In order to analyze the potential rise of ground surface of grounding grid installed in buildings, the grounding simulator has been designed and fabricated as substantial and economical measures. This paper describes the study of touch and step voltages with grounding grid where earth leakage current is injected. To assess risk voltage of grounding grid, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of an electrolytic tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the touch voltage and step voltage above the grounding grid were very low, but were significantly increased near the edge of grounding grid.