• Title/Summary/Keyword: Electrical machine maintenance

Search Result 49, Processing Time 0.032 seconds

Recent Trend on Condition Monitoring Technology of Insulating Machine in Metro (도시철도 절연기기 모니터링 기술 현황)

  • Park, Young;Jung, Ho-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.380-381
    • /
    • 2008
  • This paper consider the condition monitoring technology of electrical machine in metro substation need for efficient and effective management and diagnosis. Developing management system using condition monitoring system is very competitive field, and still to a great extent seen as an unnecessary cost. There are several approaches to maintenance management in urban transit such as reliability-centered maintenance, availability-target maintenance and preventive maintenance to advanced approaches involving condition monitoring techniques. In this paper we give a brief introduction to condition-based management and diagnosis in metro substation and which management system satisfying various demanding in railway.

  • PDF

The Study of Monitoring System for Enhancement Electrical Point-machine Maintenance (전기선로전환기 유지보수 향상을 위한 모니터링 시스템의 연구)

  • Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3115-3120
    • /
    • 2009
  • An electric point-machine which changes over a turnout so that it enables a train to be operated in the routine that a train is to proceed has been installed and used in most of the railways such as not only urban railways but also main-line railways. Most of the maintenance works in this electric point-machine is that the maintenance workers manually measure motor power, control power and display power in the site with the use of portable counters. Especially in case of NS or NS-AM electric point machine, the maintenance cycle is so frequent that during the operation casualty accidents caused by carelessness occurs as well as more staff is required for this measurement. In this paper we propose a system for monitoring the state of electric point machine installed in the site to improve maintenance efficiency and it is expected that this monitoring system confirms any measured values on electric point machines in real-time and improves maintenance efficiency.

Remote Fault Diagnosis and Maintenance System for NC Machine Tools (공작기계용 원격 고장진단 및 보수 시스템)

  • 신동수;현웅근;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.19-25
    • /
    • 1998
  • Remote fault diagnosis and maintenance system using general telecommunication network is necessary for an effective fault diagnosis and higher productivity of NC machine tools. In order to monitor machine tool condition and diagnose alarm states due to electrical and mechanical faults, a remote data communication system for monitoring of NC machine fault diagnosis and status is developed. The developed system consists of (1) remote communication module among NC's and host PC using PSTN. (2) 8 channels analog data sensing module, (3) digital I/O module for control or NC machine, (4) communication module between NC machine and remote data communication system via RS-232C, and (5) software man-machine interface. Diagnostic monitoring results generated through a successive type inference engine are displayed in user-friendly graphics. The validity and reliability of the developed system is verified to be a powerful commercial version on a vertical machining center through a series of experiments.

  • PDF

Analysis of Aging Characteristic using the Switching Current of Electrical Point Machine (선로전환기의 전환전류를 이용한 노화 특성 분석)

  • Kim, Yong-Kyu;Lee, Jong-Hyun;Kim, Ju-Yeop;Oh, Seh-Chan;Song, Yong-Soo;Baek, Jong-Hyun;Yoon, Yong-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1821-1829
    • /
    • 2017
  • A point machine requires lots of time and attention in terms of maintenance, since it causes 40% of failures among the railway signaling devices. The senescence of the point machine critically matters to the overall turnout system. In this paper, we analyzed the aging characteristics of the point machine by using the switching current of the point machine. The analysis is done based on the switching current measurements of the point machines deployed in the Sehwa outdoor test site and the Korail Kyongbu line. It is expected that the analysis result can be utilized for real-time diagnosis in the aspect of the maintenance of the point machines and predicting abnormal operations.

A Study on Efficient Interface between Point Machine and Interlocking System for High Speed and Conventional Railroad (고속 및 일반철도용 연동장치와 선로전환기간 효율적 인터페이스 방안 연구)

  • Lee, Jae-Ho;Kang, Shin-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1747-1751
    • /
    • 2014
  • Interlocking system along with point machine for efficient route control secures safety of train operation by interchanging information each other. However, various types of interlocking system and point machine operating on bender specific interface bring obstacles to effective maintenance and safety. In this paper, we have investigated on interface methods to suggest standard interface module applicable to various operating system

A Study on the Field Application of Switching Power Measurement by using Sensor in Electrical Point Machine (센서를 이용한 선로전환기 전환력 측정의 현장 적용성 연구)

  • LEE, Jong-Hyun;KIM, Yong-Kyu;PARK, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1130-1136
    • /
    • 2015
  • Most equipments which are used to measure the switching power of the turnout depend on imports. As the data is limited to the measurements of the switching power, it is said that the equipment is insufficient to check the errors of the turnout and the electrical point machine, and set up the data for operating and maintenance. We studied not only measurements of the switching power of all turnout being used in domestic but also the development of the turnout performance total analysis equipment which can measure switching time, voltage, and current etc. at the same time. Considering that switching power of the turnout is the most basic element to check the irregularities of the turnout, in this paper, we analyzed the irregularities of the turnout through correlation between switching power of the turnout, voltage, and current of the electrical point machine. Also we performed test in commercial railway line where the turnout of MJ81 type and NS type was installed. And it is said that the test results can be used as basic technologies for ICT based real-time diagnosis and monitoring of the turnout.

A Investment on Wire-wireless Communication Method for Electrical Device Infrastructure Maintenance (전력설비 관리를 위한 무선 및 유선 통신 방법에 관한 고찰)

  • Kim, Young-Eok;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.354-359
    • /
    • 2016
  • Power plants maintenance data is to be sent to management server system via a communication network. In this case, reliable communication network is required. Transmission of the power plants maintenance data is used in the wired communication network or wireless communication network. PLC communication network is a kind of wired communication network. However PLC communication network is easily affected by noise. On the vulnerable areas in power line system, such as a mountain or rural areas, it is difficult to form a power line communication network. For a wireless communication, environment are also influenced factors in wireless communication. Harsh environmental factors are bring the communication characteristic degradation. In such areas it can be used a combination of two networks and in this way the complementary function can be achieved. Power plants are distributed in various regions across the country. The appropriate communication network is needed to maintain the power plant.This study investigated the effect of environment on the wired communication and wireless communication. It would examine a variable factor which is affect to the communication characteristic. We used PLC communication for wired communication network and ZigBee communication for wireless communication network. We investigated the characteristics of a single communication network and it raised the need for a complex communication technology to complement a single communication network.

Design, Development and Analysis of Embedded Systems for Condition Monitoring of Rotating Machines using FFT Algorithm

  • Dessai, Sanket;Naaz, Zakiyaunnissa Alias Naziya
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.428-432
    • /
    • 2014
  • Rotating machines are an integral part of large electrical power machinery in most of the industries. Any degradation or outages in the rotating electric machinery can result in significant losses in productivity. It is critical to monitor the equipment for any degradation's so that it can serve as an early warning for adequate maintenance activities and repair. Prior research and field studies have indicated that the rotating machines have a particular type of signal structure during the initial start-up transient. A machine performance can be studied based on the effect of degradation in signal parameters. In this paper a data-acquisition system and the FFT algorithm has been design and model using the MATLAB and Simulink. The implementation had been carried out on the TMS320 DSP Processor and various testing and verification of the machine performance had been carried out. The results show good agreement with expected results for both simulated and real-time data. The real-time data from AC water pumps which have rotating motors built-in were collected and analysed. The FFT algorithm provides frequency response and based on this frequency response performance of the machine had been measured.The FFT algorithm provides only approximation about the machine performances.

A Study on the Control to Compensate Position Sensor Error of the BLDC Motor in an Auxiliary Air Compressor (보조 공기 압축기 내 BLDC전동기의 위치센서 오류 보상 제어)

  • Kim, In-Gun;Hong, Hyun-Seok;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1639-1644
    • /
    • 2015
  • Auxiliary air compressor(ACM) applied to railroad cars is a device which controls amount of compressed air in order that pantographs can be mounted correctly on the roof of an electric train. Existing ACMs consist of dc motors and brushes wear out due to friction with a commutator. Therefore, continuous maintenance is required. However, three phase BLDC motors have higher power density compared to dc motors and the machine maintenance is not needed because electric commutation is possible. The three phase generally uses hall sensors to get position information and this enables the accurate control. This paper suggests an algorithm that compensates the errors occurred when the hall sensors have a breakdown for stable operation.

Radiation Measurement of a Operational CANDU Reactor Fuel Handling Machine using Semiconductor Sensors (ICCAS 2003)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1220-1224
    • /
    • 2003
  • In this paper, we measured the radiation dose of a fuel handling machine of the CANDU type Wolsong nuclear reactor directly during operation, in spite of the high radiation level. In this paper we will describe the sensor development, measurement techniques, and results of our study. For this study, we used specially developed semiconductor sensors and matching dosimetry techniques for the mixed radiation field. MOSFET dosimeters with a thin oxide, that are tuned to a high dose, were used to measure the ionizing radiation dose. Silicon diode dosimeters with an optimum area to thickness ratio were used for the radiation damage measurements. The sensors are able to distinguish neutrons from gamma/X-rays. To measure the radiation dose, electronic sensor modules were installed on two locations of the fuel handling machine. The measurements were performed throughout one reactor maintenance cycle. The resultant annual cumulative dose of gamma/X-rays on the two spots of the fuel handling machine were 18.47 Mrad and 76.50 Mrad, and those of the neutrons were 17.51 krad and 60.67 krad. The measured radiation level is high enough to degrade certain cable insulation materials that may result in electrical insulation failure.

  • PDF