• 제목/요약/키워드: Electrical impedance

검색결과 2,489건 처리시간 0.023초

수평으로 매설된 도선의 접지임피던스의 주파수의존성을 계산하는 기법 (A Method of Computing the Frequency-Dependent Ground Impedance of Horizontally-buried Wires)

  • 조성철;이복희
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.745-752
    • /
    • 2016
  • The parameters of Debye's equation were applied to analyze the frequency-dependent ground impedance of horizontally-buried wires. We present a new method, based on Debye's equation, of analyzing the effect of polarization on frequency-dependent ground impedance. The frequency-dependent ground impedances of a horizontally-buried wire are directly measured and calculated by applying sinusoidal current in the frequency range of 100 Hz to 10 MHz. Also, the results obtained in this work were compared with the data calculated from empirical equations and commercial programs. A new methodology using the delta-gap source model is proposed in order to calculate frequency-dependent ground impedance when the ground current is injected at the middle-point of the horizontal ground electrode. The high frequency ground impedance of horizontal electrodes longer than 30 m is larger or equal to its low frequency ground resistance. Consequently, the frequency-dependent ground impedance simulated with the proposed method is in agreement with the experimental data, and the validity of the computational simulation approach is confirmed.

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

침상 접지봉의 임펄스접지임피던스에 미치는 지중방전의 영향 (Effects of Soil Discharges on the Impulsive Ground Impedance of Ground Rod with Needles)

  • 유양우;조성철;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.98-105
    • /
    • 2014
  • Soil discharges near the ground rod play an important role to reduce the ground potential rise and the ground impedance and to help the fault current to spread into the earth. This paper presents the effects of soil discharges on the transient and conventional ground impedances when the lightning impulse voltage was applied to a ground rod with radial needles. The current-voltage (I-V)curves and transient ground impedance curves were calculated based on the measured current and potential traces. Soil discharge behaviors related to I-V curves and transient ground impedance curves were analyzed as a function of the magnitude of lightning impulse voltages. As a result, the soil discharges occurred near the ground electrode contribute to the reduction of conventional ground impedance and limits the ground potential rise effectively under lightning impulse voltages.

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구 (Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication)

  • 이재조;유정훈;홍충선;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

질소 플라즈마의 임피이던스 특성 및 정합회로 설계 (Impedance Characteristics of N2 Plasma and Matching Circuit Design)

  • 황기웅;김원규
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.560-566
    • /
    • 1986
  • In the design of an RF discharge system, the electrical equivalence of the gas discharge must be known. With this knowledge, one can design a suitable matching network for a maximum power transfer from the RF generator into the discharge. For this purpose, an experiment has been conducted in which the electrical impedance (conductance and capacitance) was determined as a function of power. In parallel with this, a detailed theoretical analysis has been done and the results are in accord with those of our experiment. Design equations are also given for a simple matching network, and a design example is presented to demonstrate its application. During the actual operation of an RF discharge system, however, it has been often observed that the reflected power tends to vary in small values due to the changes in the impedance of the system. This problem can be relieved by adding an automatic impedance matching circuit to the system and this paper presents such an automatic impedance matching network.

  • PDF

Extended Fault Location Algorithm Using the Estimated Remote Source Impedance for Parallel Transmission Lines

  • Ryu, Jeong-Hun;Kang, Sang-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2212-2219
    • /
    • 2018
  • This paper describes extended fault location algorithm using estimated remote source impedance. The method uses data only at the local end and the sequence current distribution factors for more accurate estimation. The proposed algorithm can respond to variation of the local and remote source impedance. Therefore, this method is especially useful for transmission lines interconnected to a wind farm that the source impedance varies continuously. The proposed algorithm is very insensitive to the variation in fault distance and fault resistance. The simulation results have shown the accuracy and effectiveness of the proposed algorithm.

적응 퍼지 임피던스 제어기의 개발에 관한 연구 (A Study on Implementation of Adaptive Fuzzy Impedance Controller)

  • 임용택;장성민;김승우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2819-2821
    • /
    • 2000
  • We introduce Adaptive Fuzzy Impedance Controller for force control when robot contact with environment. Because robot and environment was always effected by nonlinear conditions. it needs to deal with parameter's uncertainty. As. it induced Fuzzy system in impedance controller. it used fuzzy inference logic that has robustness about uncertainty to tune impedance controller stiffness gain. We applied adaptive fuzzy impedance controller in One-Link Robot system and the method shows a good performance on desired position and force control with intensional contacting environment.

  • PDF

시간지연 신경회로망을 이용한 고장지락사고 검출 (Detection of High Impedance Fault based on Time Delay Neural Network)

  • 최진원;이종호;김춘우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.405-407
    • /
    • 1994
  • In order to provide reliable power service and to prevent a potentail hazard and damage, it is important to detect high impedance fault in power distribution line. This paper presents a neural network based approach for the detection of high impedance faults. A time delay neural network has been selected and trained for the fault currents obtained from field experiments. Detection experiments have been performed with the data from four different high impedance surfaces. Experimental results indicated the feasibility of using TDNN for the detection of high impedance faults.

  • PDF

조작자 근육 활성도 기반 양팔 로봇의 임피던스 제어 파라미터 갱신 방법 (Impedance Parameter Update Method for Dual-arm Manipulator based on Operator's Muscle Activation)

  • 백찬렬;차광열;김준식;최영진
    • 로봇학회논문지
    • /
    • 제17권3호
    • /
    • pp.347-352
    • /
    • 2022
  • The paper presents how to update impedance control parameters for dual-arm manipulators using EMG signals and motions of the operator. Since the hand motions of the dual-arm are modeled to be the mass-spring-damper system in this paper, the impedance parameter update method is an important issue to reflect the operator's force. However, task space inertia to be used as the mass parameter goes to infinity if the manipulator approaches a kinematic singularity. To alleviate this issue, the impedance (stiffness and damping) parameters are divided with a diagonal element of the task space inertia. Also, the stiffness and damping matrices are updated using the normalized EMG signals captured from the operator's forearm. Through this process, the motion of the dual-arm manipulator is more stabilized even though it approaches the kinematic singularity.

광대역 초음파 변환기를 위한 전기 임피던스 정합 연구 (Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer)

  • 김건우;김기복;백광세
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 초음파탐상법을 이용하여 마이크로미터의 크기 작은 결함을 검출하기 위해서는 높은 공진주파수와 큰 분해능의 초음파 변환기가 필요하다. 초음파 변환기의 공진주파수와 분해능은 변환기에 사용된 압전소자의 두께, 후면재 및 탐상 시스템 간의 전기 임피던스 정합과 밀접한 관련이 있으며, 이 중 전기 임피던스 매칭은 초음파 변환기와 초음파탐상 시스템 사이의 서로 다른 입 출력단을 연결하는 과정에서, 두 연결단의 전기적 임피던스 차이에 의한 에너지 반사와 손실을 줄이는 중요한 역할을 한다. 임피던스 정합에서 흔히 많이 사용하는 방법은 LC-정합회로이다. 이러한 LC-정합을 통해 탐상 시스템과 초음파 변환기의 전기 임피던스를 $50{\Omega}$으로 맞추어 두 연결단 사이의 임피던스 차이를 보정해 줌으로서 초음파 변환기에서 발생되는 전기신호의 손실을 줄 수 있다. 본 연구에서는 15 MHz의 공진주파수를 가지는 광대역 수침형 초음파 탐촉자를 제작하고 광대역 특성을 갖는 초음파 변환기를 위한 LC 임피던스 정합법을 적용하였다.