• 제목/요약/키워드: Electrical distribution systems

검색결과 1,211건 처리시간 0.028초

Cyber Threat and a Mitigation Method for the Power Systems in the Smart Grid

  • Kim, Myongsoo;Kim, Younghyun;Jeon, Kyungseok
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1043-1050
    • /
    • 2014
  • Obsolescent control systems for power systems are evolving into intelligent systems and connecting with smart devices to give intelligence to the power systems. As networks of the control system are growing, vulnerability is also increasing. The communication network of distribution areas in the power system connects closely to vulnerable environments. Many cyber-attacks have been founded in the power system, and they could be more critical as the power system becomes more intelligent. From these environment, new communication network architecture and mitigation method against cyber-attacks are needed. Availability and Fault Tree analysis used to show that the proposed system enhances performance of current control systems.

직격뢰 침입시 배전계통 절연설계 (Insulation Design of Distribution Systems in Case of the Stroke of Direct Lightning Surge)

  • 정채균;김상국;이종범;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.238-247
    • /
    • 2004
  • This paper describes the insulation coordination scheme of line in distribution system when the direct lightning surge strikes. The BIL that is applied to distribution system is not properly considered the performance and operation of arresters. Because of that, the high BIL is being used at partial system. This paper variously analyses the lightning overvoltage of line and equipment with earth of overhead grounding wire and installation types of arrester. From these result. authors examine the rationality of BIL.

Multi-objective Unbalanced Distribution Network Reconfiguration through Hybrid Heuristic Algorithm

  • Mahendran, G.;Sathiskumar, M.;Thiruvenkadam, S.;Lakshminarasimman, L.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.215-222
    • /
    • 2013
  • Electrical power distribution systems are critical links between the utility and customer. In general, power distribution systems have unbalanced feeders due to the unbalanced loading. The devices that dependent on balanced three phase supply are affected by the unbalanced feeders. This necessitates the balancing of feeders. The main objective of reconfiguration is to balance the loads among the phases subject to constraints such as load flow equations, capacity and voltage constraints and to reduce the real power loss, while subject to a radial network structure in which all loads must be energized. Therefore, the distribution system reconfiguration problem has been viewed as multi-objective problem. In this paper, the hybrid heuristic algorithm has been used for reconfiguration, which is the combination of fuzzy and greedy algorithms. The purpose of the introduction of greedy is to refrain the searching for the period of phase balancing. The incorporation of fuzzy helps to take up more objectives amid phase balancing in the searching. The effectiveness of the proposed method is demonstrated through modified IEEE 33 bus and modified IEEE 125 bus radial distribution system.

태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구 (A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems)

  • 김찬혁;박현석;노대석;신창훈;윤기갑
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

배전계통 고장위치 검출방법에 관한 연구 (A Study on the Estimating Locations of Faults on Distribution Power Systems)

  • 김미영;오용택;노대석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권12호
    • /
    • pp.670-677
    • /
    • 2004
  • The Conventional approach for estimating the locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and to convert the reactive component of the impedance to line length. But, these methods do not adequately address the problems associated with the fault location on distribution systems. This thesis presents a technique that estimates the location of shunt fault on a radial distribution system that has several single and multiphase laterals. Tapped loads and non-homogenity of the distribution system are take into account. The developed technique, which can handle shunt faults was tested to evaluate its suitability. Results from computer simulation of faults on a model of a 25KV distribution lines like real system are presented. The results approved that the proposed technique works well for estimating the locations of the distribution line shunt faults.

2회선 배전계통에서 피뢰기 설치방법에 따른 차폐 효과 분석 (Analysis of Shielding Effect with Installation Methods of Arresters in Double Circuits Distribution Systems)

  • 정채균;김상국;이종범;정영호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.104-110
    • /
    • 2004
  • This paper describes the lightning overvoltage occurred differently according to installation methods of arresters and overhead grounding wire in case of double circuits distribution systems. First, the analysis models are established considering the severe case between upper and lower distribution line, when the direct lightning surge strikes to the overhead grounding wire. The lightning overvoltage is variously analyzed with the change of grounding interval and resistance, arrester installation interval as well as the magnitude of surge using EMTP. After simulation results are compared with the BIL which is now used at field, the authors propose the methods for suitable shielding in domestic distribution systems.

배전계통 재구성 문제를 위한 Harmony Search 알고리즘 응용 (Harmony Search Algorithm for Network Reconfiguration Problem in Distribution Systems)

  • 이상봉;김규호;김철환
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1667-1673
    • /
    • 2009
  • This paper presents a application of new algorithm for feeder reconfiguration problem in distribution systems. Harmony Search (HS) algorithm, which is motivated from the musical performance, is used to reconfigure distribution systems so that active power losses are globally minimized with turning on/off the sectionalizing and the tie-line switches. In optimization processing, the HS algorithm has searching ability for the global optimal solution, simple coding of the iteration procedure, and fast convergence to get the solution. The HS algorithm is tested on 15 buses and 69 buses distribution systems, and the results prove its effectiveness to determine appropriate switching options without the occurrence of any misdetermination in switching and get the minimum power loss.

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2219-2220
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.587-588
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1253-1254
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF