• Title/Summary/Keyword: Electrical distribution systems

Search Result 1,216, Processing Time 0.034 seconds

Voltage Control in Distribution System using Reliability Indices (공급신뢰도(供給信賴度)를 고려(考慮)한 배전계통(配電系統)의 전압(電壓) 관리(管理))

  • Jang, Jeong-Tae;Hong, Sun-Hak;Kim, Kern-Joong;Sim, Kuk-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.214-217
    • /
    • 1990
  • The voltage of distribution systems is controlled according to the proper rate of voltage drop and the loss constraints etc.. In modern distribution system it is necessary to supply energy according to the priority of reliabilities of the system. This paper proposes an efficient algorithm of the management of distribution systems considering the system reliabilities and gives a more accurate and economic control of the voltage of distribution systems.

  • PDF

Analysis of Transient Phenomena Considering Transformer Model in Underground Distribution Systems (지중배전계통에서 변압기 모델을 고려한 과도현상 해석)

  • Yun, Chang-Sub;Lee, Jong-Beom;Song, Il-Kun;Kim, Byong-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.151-153
    • /
    • 2006
  • This paper describes the transient phenomena considering transformer model in combined distribution systems with power cables. To evaluate the overvoltage, the change of transformer model and system structure are considered. Transformer parameters calculated by BCTRAN of EMTP are considered to evaluate surge generation in underground distribution systems when underground distribution system has various parameters. It is evaluated that overvoltage value increases and decreases according to the structure of system. However it is confirmed that there is not much effect to overvoltage as transformer is operated in distribution line.

  • PDF

The Analysis of Voltage Variations at Distribution System Interconnected Multiple PV Systems (다수 PV 시스템 배전계통 연계 시 전압변동 분석)

  • Kang, Chul;Shin, Hee-Sang;Cho, Sung-Min;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.177-178
    • /
    • 2008
  • Recently, the concern of PV(Photovoltaic) systems has increased because of an environmental problem and limitation of fossil fuel. In this paper, distribution system of existing one-way power flow and distribution system generating bidirectional power flow analyze voltage variation at distribution system interconnected multiple PV systems. Also, we analyze a supply voltage range of distribution system using LDC and ULTC voltage regulation method by case study.

  • PDF

The Study on Permissible Capacity of Distributed Generation Considering Voltage Variation and Load Capacity at the LV Distribution Power System (전압변동과 부하량을 고려한 저압배전계통의 분산전원 설치용량 분석)

  • Moon, Won-Sik;Cho, Sung-Min;Shin, Hee-Sang;Lee, Hee-Tae;Han, Woon-Ki;Choo, Dong-Wook;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.100-105
    • /
    • 2010
  • This paper describes a capacity of distributed generation which will be interconnected at low voltage distribution systems. In order to set the capacity of distributed generation, a voltage variation of distribution system is considered. Besides, the capacity of distributed generation is classified according to a capacity of pole transformer and loads. The system constructions in this paper are analyzed by using PSCAD/EMTDC. In the immediate future, it is expected to increase the installation of New and renewable energy systems which are generally interconnected to distribution power systems in the form of distributed generations like photovoltaic system, wind power and fuel cell. So the study of this kind would be needed to limit the capacity of distributed generation.

The Development of Multi-Fault Restoration Algorithm for Distribution Network (배전계통 광역 정전복구 알고리즘 개발)

  • Jung, Jin-Soo;Lee, Seung-Jae;Jung, Jong-Wook;Lim, Young-Bae;Bae, Seok-Myung;Yi, Geon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.69-77
    • /
    • 2006
  • This paper presents the service restoration in electric power distribution systems. The aim of the service restoration is to control an emergency taken place in distribution systems and to restore out-of service areas as soon as possible when a fault occurs in distribution systems. For this reason, new service restoration strategies in multi-outage area are suggested in this paper. The suggested algorithm consist of two schemes. One is an individual restoration scheme, the other is an integrated restoration scheme. The former determines a restoration order of outage areas based on a restoration index. Unless the former scheme can generate a feasible restoration plan, the latter one will try to find out a new configuration without an overloaded section through tie exchange method.

The Investment Scheme of the Maintenance Planning with Limited Investment Budget in the Distribution Systems for Minimizing the Interruption Cost (제한된 투자 예산으로 정전비용 최소화를 위한 배전계통 유지보수 계획의 투자 방안)

  • Hwang, Won-Il;Kim, Kyu-Ho;Kim, Hong-Rae;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.1-7
    • /
    • 2010
  • The reliability of a power system has close relationship with the maintenance of the distribution systems. This paper presents the method of the maintenance planning of the distribution systems by minimizing the interruption cost. The interruption cost for the equipment failures is formulated using time varying failure rate and minimized by optimization of the object function. The proposed method provides the priority list for the investment of the maintenance subject to the limited investment budget by the economic analysis. In order to test the proposed method, the modified distribution system of a rural area is introduced for the testing system. Test results show that the proposed method is good enough by evaluating the improvement of the reliability of the power system.

Implementation of a Inference based Intelligent Distribution Panel System for Prevention and fast Detection of fire caused by Electricity (전기화재 예방과 신속 감지를 위한 추론기반 지능형 수배전반 시스템 구현 연구)

  • Park, Chan-Eom;Kim, Kyung-Dong;Lee, Seung-Chul;Yang, Won-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.82-85
    • /
    • 2006
  • With the fast growing number of skyscrapers and large ultrahigh apartment complexes, the concerns on fire caused by electricity also grow. Among about 30,000 fires recorded annually, roughly one third of them are hewn to be caused by electricity. If one of such high and densely populated buildings or apartments catches a fire, the consequence can potentially be quite catastrophic. However, with the rapid development of the techniques in the fields of communications and computers, electric power distribution systems for such buildings and apartments have been largely digitalized in recent years. More detailed informations on the operating status are now available, which enables more sophisticated monitoring and early detection of potential fire caused by electricity. In this paper, we present an inference technique that can be used as one of the basic techniques in building intelligent distribution panel systems that can effectively monitor, prevent and detect the occurrence of fire caused by electricity. The technique can accommodate production rules in linguistic expressions on high abstraction levels. Fire finding strategies can be easily modified to provide more effective countermeasures. Simulation results show that inference capabilities and thus the capability of fire monitoring in power distribution panel systems can be significantly enhanced with our approach.

  • PDF

Trend for Managing Electrical Distribution Equipments Using a Wireless Sensors (배전 설비의 무선 통신을 이용한 배전 설비의 신뢰성 향상 기술 동향)

  • Lee, Ju-Hong;Yun, Ju-Ho;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.543-544
    • /
    • 2007
  • This paper introduce methods and analysis of a simple wireless sensor concept for detecting and locating faults as well as for load monitoring are presented. The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF

Developing a New Risk Assessment Methodology for Distribution System Operators Regulated by Quality Regulation Considering Reclosing Time

  • Saboorideilami, S.;Abdi, Hamdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1154-1162
    • /
    • 2014
  • In the restructured electricity market, Performance-Based Regulation (PBR) regime has been introduced to the distribution network. To ensure the network stability, this regime is used along with quality regulations. Quality regulation impose new financial risks on distribution system operators (DSOs). The poor quality of the network will result in reduced revenues for DSOs. The mentioned financial risks depend on the quality indices of the system. Based on annual variation of these indices, the cost of quality regulation will also vary. In this paper with regard to reclosing fault in distribution network, we develop a risk-based method to assess the financial risks caused by quality regulation for DSOs. Furthermore, in order to take the stochastic behavior of the distribution network and quality indices variations into account, time-sequential Monte Carlo simulation method is used. Using the proposed risk method, the effect of taking reclosing time into account will be examined on system quality indicators and the cost of quality regulation in Swedish rural reliability test system (SRRTS). The results show that taking reclosing fault into consideration, affects the system quality indicators, particularly annual average interruption frequency index of the system (SAIFI). Moreover taking reclosing fault into consideration also affects the quality regulations cost. Therefore, considering reclosing time provides a more realistic viewpoint about the financial risks arising from quality regulation for DSOs.

Reliability evaluation of distribution systems vs. the optimal load transferring using genetic algorithms (유전 알고리즘을 이용한 최적부하절체에 의한 배전계통의 신뢰도 평가)

  • Han, Seong-Ho;Choi, Joon-Ho;Choi, Do-Hyuk;Rhee, Wook;Choi, Dai-Seub;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.862-864
    • /
    • 1996
  • This paper presents a new approach to evaluate reliability indices of electric distribution systems using genetic algorithm(GA). The use of reliability evaluation is an important aspect of distribution system planning and operation to adjust the reliability level of each area. In this paper, the reliability model is based on the optimal load transferring problem to minimize over load generated load point outage in each sub-section. This kind of the approach is one of the most difficult procedure which becomes a combination problems. A new approach using GA Was developed for this problem. We proposed a tree search algorithm which satisfied the tree constraint. GA is general purpose optimization techniques based on principles inspired from the biological evolution such as natural selection, genetic recombination and survival of the fittest Test results for the model system with 24 nodes and 29 branches are reported in the paper.

  • PDF