• Title/Summary/Keyword: Electrical distribution systems

Search Result 1,212, Processing Time 0.028 seconds

Analysis of Anisotropic Characteristic in Fiber Reinforced Polymer for the Knee Brace Using the Eddy Current Inspection (와전류 탐상기법을 이용한 무릎보조기용 섬유강화 폴리머의 이방특성 분석)

  • Kim, Cheol-Woong;Park, Cheon-Woong;Shin, Yong-Hoon;Seo, Hae-Young;Lee, Ho-Sang
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1533-1538
    • /
    • 2008
  • The development of new material systems like Carbon Fiber Reinforced Polymer (CFRP) places ever higher demands on the techniques for non-destructive material characterisation. Image-producing eddy current methods also need to satisfy these demands. Eddy-current imaging of FRP is based on the anisotropic electrical properties of the material investigated. Significant differences in conductivity between carbon fibres, polymer matrix and integrated functional components can be found. The availability of high-resolution sensors enables access to the local distribution of the electromagnetic properties. The static and dynamic procedures for isolating influential characteristics, already in use in eddy-current technology, can now be supplemented by topographical images. The precondition for a successful implementation of the eddy-current procedure is a deeper understanding of the image-generating process which allows correct interpretation of the images obtained.

  • PDF

Measurement of Zeta-potential of Electro-osmotic Flow Inside a Micro-channel (마이크로 채널 내부 전기삼투 유동의 Zeta-potential 계측)

  • Han Su-Dong;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.935-941
    • /
    • 2006
  • Many important properties in colloidal systems are usually determined by surface charge $({\zeta}-potential)$ of the contacted solid surface. In this study, ${\zeta}-potential$ of glass ${\mu}-channel$ was evaluated from the electro-osmotic velocity distribution. The electro-osmotic velocity inside a glass f-channel was measured using a micro-PIV velocity field measurement technique. This evaluation method is more simple and easy to approach, compared with the traditional streaming potential technique. The ${\zeta}-potential$ in the glass ${\mu}-channel$ was measured fur two different mole NaCl solutions. The effect of an anion surfactant, sodium dodecyl sulphate (SDS), on the electro-osmotic velocity and f-potential in the glass surface was also studied. In the range of $0{\sim}6mM$, the surfactant SDS was added to NaCl solution in few different mole concentrations. As a result, the addition of SDS increases ${\zeta}-potential$ in the surface of the glass ${\mu}-channel$. The measured $\zeta-potential$ was found to vary from -260 to -70mV. When negatively charged particles were used, the flow direction was opposite compared with that of neutral particles. The ${\zeta}-potential$ has a positive sign for the negative particles.

Service Scheduling in Cloud Computing based on Queuing Game Model

  • Lin, Fuhong;Zhou, Xianwei;Huang, Daochao;Song, Wei;Han, Dongsheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.5
    • /
    • pp.1554-1566
    • /
    • 2014
  • Cloud Computing allows application providers seamlessly scaling their services and enables users scaling their usage according to their needs. In this paper, using queuing game model, we present service scheduling schemes which are used in software as a service (SaaS). The object is maximizing the Cloud Computing platform's (CCP's) payoff via controlling the service requests whether to join or balk, and controlling the value of CCP's admission fee. Firstly, we treat the CCP as one virtual machine (VM) and analyze the optimal queue length with a fixed admission fee distribution. If the position number of a new service request is bigger than the optimal queue length, it balks. Otherwise, it joins in. Under this scheme, the CCP's payoff can be maximized. Secondly, we extend this achievement to the multiple VMs situation. A big difference between single VM and multiple VMs is that the latter one needs to decide which VM the service requests turn to for service. We use a corresponding algorithm solve it. Simulation results demonstrate the good performance of our schemes.

Performance Analysis of A Hybrid Codebook for LTE Downlink Relay Systems (LTE 하향 링크 중계기 시스템에서 새로운 하이브리드 코드북 성능 분석)

  • Kim, Hyung-Jun;Park, Noe-Yoon;Kim, Young-Ju
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.462-469
    • /
    • 2011
  • In this paper, we propose a novel hybrid codebook design method which combines DFT matrix based codebook for Rayleigh fading and LOS codebook for direct path. Link-level performances employing hybrid codebook outperform the ones employing the conventional codebooks when K-factor of Rician distribution is 0.28 to 0.99. Moreover hybrid codebook shows good performances over not only Rayleigh channel but also high K's Rician channels.

Incorporating Resource Dynamics to Determine Generation Adequacy Levels in Restructured Bulk Power Systems

  • Felder, Frank A.
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.2
    • /
    • pp.100-105
    • /
    • 2004
  • Installed capacity markets in the northeast of the United States ensure that adequate generation exists to satisfy regional loss of load probability (LOLP) criterion. LOLP studies are conducted to determine the amount of capacity that is needed, but they do not consider several factors that substantially affect the calculated distribution of available capacity. These studies do not account for the fact that generation availability increases during periods of high demand and therefore prices, common-cause failures that result in multiple generation units being unavailable at the same time, and the negative correlation between load and available capacity due to temperature and humidity. A categorization of incidents in an existing bulk power reliability database is proposed to analyze the existence and frequency of independent failures and those associated with resource dynamics. Findings are augmented with other empirical findings. Monte Carlo methods are proposed to model these resource dynamics. Using the IEEE Reliability Test System as a single-bus case study, the LOLP results change substantially when these factors are considered. Better data collection is necessary to support the more comprehensive modeling of resource adequacy that is proposed. In addition, a parallel processing method is used to offset the increase in computational times required to model these dynamics.

The Development of Gateway System for Power Automation based on TETRA (TETRA 기반 전력자동화 게이트웨이 시스템 개발)

  • Song, Byung-Kwen;Kim, Geon-Ung
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.41-50
    • /
    • 2010
  • TETRA is the standard of Digital Trunked Radio System suggested by the ETSI(European Telecommunications Standards Institut ). It is adopted as Electric Power IT Wireless Backbone Network in Korea. Police station and Fire Station are using TETRA network. Currently, Power Automation Protocols are DNP3.0 in Distribution Automation System, DLMS in Auto Metering Infrastructure, IEC61850 in Substation Automation. These protocols are transmissions using CDMA or WCDMA modem. If Power Automation protocol uses TETRA networks, it can be interoperable with the systems in police or fire stations. And it has outstanding ability to handle problems in a disaster situation. So, This paper propose a gateway system of Power Automation which can transmit the power automation protocol using TETRA.

An Experimental Study on the Effect of Electrohydrodynamic Monodisperse Atomization According to Nozzle Characteristics (노즐 특성에 따른 전기수력학적 단분산 미립화 효과에 관한 실험적 연구)

  • Sung, K.A.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.18-31
    • /
    • 2005
  • This study was performed to explore the liquid breakup and atomization characteristics for the classification of drop formation mode and background of uniform droplets generation in electrohydrodynmaic atomization according to the change of experimental parameters such as nozzle material (stainless steel. teflon). fluid flow rate, applied electrical field and intensity, and frequency. In results, from the classification map of drop formation modes according to the variation of applied AC voltage and frequency at a stainless nozzle, the droplet size was smaller than the outer diameter of the nozzle tip relatively in the spindle mode. The transition points became clearly to be moved toward the high applied voltage by rising the applied AC frequency beyond 450Hz. Also the droplet radius can be observed quite small in the frequency bandwidth of $350{\sim}450Hz$. The droplet radiuses decrease as the applied voltage increases for a fixed applied AC frequency within the range from 50Hz to 400Hz Over 400Hz, the relation between the power intensity and the droplet size was not consistent with a continuous mechanism of liquid breakup. Thus, it is showed that the droplet size distribution using the teflon nozzle was analogous to the results of stainless steel, but the droplet size was bigger than that of stainless steel relatively in case of a teflon nozzle.

  • PDF

On the Outage Behavior of Interference Temperature Limited CR-MISO Channel

  • Kong, Hyung-Yun;Asaduzzaman, Asaduzzaman
    • Journal of Communications and Networks
    • /
    • v.13 no.5
    • /
    • pp.456-462
    • /
    • 2011
  • This paper investigates the outage behavior of peak interference power limited cognitive radio (CR) networks with multiple transmit antennas. In CR-multi-input single-output (MISO) channel, the total transmit power is distributed over the transmitantennas. First, we use the orthogonal space-time codes (STC) to achieve the transmit diversity at CR-receiver (rx) and investigate the effect of the power distribution on the interference power received at the primary-receiver (P-rx). Then, we investigate the transmit antenna selection (TAS) scheme in which the CR system selects the best transmit antenna and allocates all the power to the selected best antenna. Two transmit antenna selection strategies are proposed depending on if feedback channel is available or not. We derive the closed form expressions of outage probability and outage capacity of all schemes with arbitrary number of transmit-antennas. We show that the proposed schemes significantly improve the outage capacity over the single antenna systems in Rayleigh fading environment. We also show that TAS based scheme outperforms the STC based scheme when peak interference power constraint is imposed on the P-rx only if a feedback channel from CR-rx to CR-transmitter is available.

Economic Evaluation of Step Voltage Regulator in Distribution Systems (배전계통에 있어서 선로전압조정장치의 경제성 평가에 관한 연구)

  • Rho, Dae-Seok;Lee, Eun-Mi;Park, Chang-Ho;Kim, Eung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.140-143
    • /
    • 2003
  • 배전선로에서 부하가 증가함에 따라 주상변압기의 탭 조정만으로는 모든 수용가단 전압을 규정치($220{\pm}6%$) 이내로 유지시킬 수가 없게 된다. 따라서, 수용가단 전압의 품질을 규정치 이내로 유지할 수 있는 보강공사가 필요하게 된다. 현재는 수용가단 전압품질에 문제가 발생하지 않으나, 선로의 부하가 증가 될수록 통과전류의 양이 많아져, 전압강하가 높아지기 때문에 일부 수용가에 저전압이 발생하게 될 가능성이 있게 된다. 여기서는 부하증가(부하증가율 : 1%, 2%, 3%, 4%, 5%)에 대한 대책으로 다음과 같은 3가지 대안을 고려하기로 한다. 본 연구에서는 1) 선로전압조정장치(SVR)의 설치 2) 회선증강(ACSR $95mm^2$ $\rightarrow$ ACSR $160mm^2$) 3) 회선신설(전압강하 5%이상 지점에 회선 추가)에 대한 경제성을 현재가치 환산법에 의해 평가해 보고, 가장 적정한 대안을 제안하여 배전계통 계획 및 운용에 대한 합리적인 투자 대안을 제시한다.

  • PDF

CCAJS: A Novel Connect Coverage Algorithm Based on Joint Sensing Model for Wireless Sensor Networks

  • Sun, Zeyu;Yun, Yali;Song, Houbing;Wang, Huihui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.5014-5034
    • /
    • 2016
  • This paper discusses how to effectively guarantee the coverage and connectivity quality of wireless sensor networks when joint perception model is used for the nodes whose communication ranges are multi-level adjustable in the absence of position information. A Connect Coverage Algorithm Based on Joint Sensing model (CCAJS) is proposed, with which least working nodes are chosen based on probability model ensuring the coverage quality of the network. The algorithm can balance the position distribution of selected working nodes as far as possible, as well as reduce the overall energy consumption of the whole network. The simulation results show that, less working nodes are needed to ensure the coverage quality of networks using joint perception model than using the binary perception model. CCAJS can not only satisfy expected coverage quality and connectivity, but also decrease the energy consumption, thereby prolonging the network lifetime.