• 제목/요약/키워드: Electrical conductance

검색결과 299건 처리시간 0.027초

Highly Sensitive and Transparent Pressure Sensor Using Double Layer Graphene Transferred onto Flexible Substrate

  • Chun, Sungwoo;Kim, Youngjun;Jin, Hyungki;Jung, Hyojin;Park, Wanjun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.229.2-229.2
    • /
    • 2014
  • Graphene, an allotrope of carbon, is a two-dimensional material having a unique electro-mechanical property that shows significant change of the electrical conductance under the applied strain. In addition of the extraordinary mechanical strength [1], graphene becomes a prospective candidate for pressure sensor technology [2]. However, very few investigations have been carried out to demonstrate characteristics of graphene sensor as a device form. In this study, we demonstrate a pressure sensor using graphene double layer as an active channel to generate electrical signal as the response of the applied vertical pressure. For formation of the active channel in the pressure sensor, two single graphene layers which are grown on Cu foil (25 um thickness) by the plasma enhanced chemical vapor deposition (PECVD) are sequentially transformed to the poly-di-methyl-siloxane (PDMS) substrate. Dry and wet transfer methods are individually employed for formation of the double layer graphene. This sensor geometry results a switching characteristic which shows ~900% conductivity change in response to the application of pulsed pressure of 5 kPa whose on and off duration is 3 sec. Additionally, the functional reliability of the sensor confirms consistent behavior with a 200-cycle test.

  • PDF

Polyimide(PI)LB막의 MIM구조 소자내에서의 switching전도특성 (Switching conduction characteristics of PI LB Film in MIM junctions)

  • 김태성;김현종
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.176-183
    • /
    • 1995
  • The present work is concerned with the switching conduction characteristics of PI LB films in metal insulator metal sandwiches. By applying various DC voltage bias to MIM junctions, conduction characteristics of junctions can be changed between the high-voltage low-current(off) condition, the low-voltage high-current (on) condition and the medium(mid) condition. Switching conduction characteristics can be also observed in MIM junctions employing some aromatic compounds as insulators. Switching conduction characteristics is assumed to be owing to the existence of aromatic rings, space charge in films, impurities on metal-insulator interface, and difference in work functions of base and top electrodes metal. To study the conduction process of on, off, and mid conductions, we measured I-V, d$^{2}$V/d I$^{2}$-V characteristics of junctions with several different top electrodes under various temperatures. Small conductance changes of junctions can be measured by observing the second derivative, d$^{2}$V/dI$^{2}$, of I-V curve. A dynamical technique is used to get the second derivatives. That is, a finite modulation of the current is applied to the junctions and the second harmonic of the voltage is detected.

  • PDF

반응성 RF 마그네트론 스퍼터링 법을 이용한 AIN/SiC 구조의 제작 및 특성 (Fabrication and Properties of AIN/SiC Structures using Reactive RF Magnetron Sputtering Method)

  • 김용성;김광호
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.977-982
    • /
    • 2005
  • Al/AlN/n-type 6H-SiC (0001) MIS structures were prepared by AlN layers on vicinal 6H-SiC(0001) substrates with reactive RF magnetron sputtering method. The AlN films were annealed at $900^{\circ}C$, $N_2$ atmosphere lot 1 minutes showed the best result. With XRD analysis, AlN(0002) peak was clearly found. The typical dielectric constant value of the AlN film in the MIS capacitors was obtained as 8.4 from photo C-V. Also, the gate leakage current density of the MlS capacitor was $10^{-10}\;A/cm^2$ order within the electric field of 1.8 MV/cm. Finally, the amount of interface trap densities, $D_{it}$, was evaluated as $5.3\times10^{10}\;eV^{-1}cm^{-2}$ at (Ec-0.85) eV.

A Novel MPPT Control of a Photovoltaic System using an FLC Algorithm

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.17-25
    • /
    • 2014
  • This paper proposes a novel maximum power point tracking (MPPT) system using a fuzzy logic control (FLC) algorithm for robust in-environment changing. The power available at the output of a photovoltaic (PV) cell continues to change with radiation and temperature because a solar cell exhibits nonlinear current-voltage characteristics. Therefore, the maximum power point (MPP) of PV cells varies with radiation and temperature. The MPPT methods are used in PV systems to make full utilization of the PV array output power, which depends on radiation and temperature. The conventional MPPT control methods such as constant voltage (CV), perturbation and observation (PO) and incremental conductance (IC) have been studied but these methods are problematic in that they fail to take into account the changing environment. The proposed FLC controller is based on the fuzzy control algorithm and facilitates robust control with the environmental changes. Also, the PV systems applied FLC controller is modeled by PSIM and the response characteristics of the FLC method according to environmental variations are analyzed through comparison with the performance of conventional methods. The validity of this controller is shown through response results.

HBPI 제어기를 이용한 태양광발전 시스템의 MPPT 제어 (MPPT Control of Photovoltaic System using HBPI Controller)

  • 고재섭;정동화
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1864-1871
    • /
    • 2012
  • This paper proposes the hybrid proportional integral(HBPI) controller for maximum power point tracking(MPPT) control of photovoltaic system. The output characteristics of the solar cell are a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. The MPPT control is a very important technique in order to increase an output and efficiency of the photovoltaic system. The conventional constant voltage(CV), perturbation and observation(PO) and incremental conductance(IC) are the method which finding maximum power point(MPP) by the continued self-excitation vibration, and uses the fixed step size. If the fixed step size is a large, the tracking speed of maximum power point is faster, but the tracking accuracy in the steady state is decreased. On the contrary, when the fixed step size is a small, the tracking accuracy is increased and the tracking speed is slower. Therefore, in order to solve these problems, this paper proposes HBPI controller that is adjusted gain of conventional PI control using fuzzy control, and the maximum power point tracks using this controller. The validity of the controller proposed in this paper proves through the results of the comparisons.

MLPO 방법을 이용한 태양광 발전의 MPPT 제어 (MPPT Control of Photovoltaic Generation Using MLPO Method)

  • 최정식;정동화
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2064-2075
    • /
    • 2011
  • In this paper, robust multi-level perturbation and observation (MLPO) maximum power point tracking (MPPT) control are presented of the environmental change including the solar radiation and temperature. Because the maximum power point of the Photovoltaic (PV) is changing according to the solar radiation and temperature, the technology which traces the maximum power point in order to increase the power efficiency is recognized as the very important part. The general requirement for the MPPT is that system is simple, the cost is inexpensive, the PV tracking function and output change are small. Conventional perturbation and observation (PO) method is a simple system but there is the disadvantage that an efficiency of system becomes low. In addation, the incremental conductance (IC) control is required expensive CPU because of a large of calculations. In order to solve this problem, in this paper, the MLPO MPPT control using the method diversifying the step size according to the environment condition is presented. The validity of the MLPO method presenting from this paper is proved through analyzing the solar power generation output error at the steady state.

그림자 영향을 고려한 PV MIC 시스템의 새로운 MPPT 제어 (A Novel MPPT Control of PV MIC System Considering the Shaded Effect)

  • 최정식;정동화
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.21-33
    • /
    • 2012
  • This paper presents the new maximum power point tracking(MPPT) control of the photovoltaic(PV) module integrated converter(MIC) system considering the shadow influence. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. Particularly, MIC system is very sensitive to the shadow influence because the capacity is very small. In order to increase an output and efficiency of the solar power generation, the maximum power point(MPP) obeying control are necessary. Conventional perturbation and observation(PO) and Incremental conductance(IC) are the method finding MPP by the continued self-excitation vibration. The MPPT control is unable to be performed by rapid output change affected by the shadow. To solve this problem, the new control algorithm of the multi-level in which the step value changes by output change is presented. In case there are the solar radiation, a temperature and shadow influence, the presented algorithm treats and compares the conventional control algorithm and output error. In addition, the validity of the algorithm is proved. through the output error response characteristics.

최대 전력 평형/불평형 경계점 제어를 이용한 MPPT제어에 관한 연구 (A Study on MPPT Control using the Maximum Power Balance/Unbalance Boundary Point Control)

  • 고강훈;강태경;이현우;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.33-38
    • /
    • 2006
  • This paper proposes a simple MPPT control scheme of a based Current-Control-Loop system that can be obtains a lot of advantage to compare with another digital control method, P&O(Perturbation and Observation) and IncCond(Incremental Conductance) algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance Problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment results on battery charger using PIC that is the microprocessor of a low price.

λ/4 흡수층 구조를 갖는 NDIR 이산화탄소 가스센서용 적외선 센서의 제조 및 특성 (Fabrications and Characteristics of Infrared Sensor Composed of λ/4 Absorbing Structure for the Application of NDIR CO2 Gas Sensor)

  • 이성현;남태운
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1005-1009
    • /
    • 2008
  • A noble infrared $\lambda/4$ absorbing structure using metal reflector was studied for uncooled infrared sensors. This paper described the design and the fabrication of IR uncooled detectors which were composed of 21 by 21 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of 4.26 ${\mu}m$. The fabricated detectors exhibited the thermal mass of $9.75\times10^{-9}$ J/K, the thermal conductance of $1.31\times10^{-6}$ W/K, the thermal time constant of 7.4 ms, the responsivity of $1.07\times10^5$ V/W and the detectivity of $1.04\times10^9$ $cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of 9.22${\mu}A$. Finally the absorptance efficiency of $\lambda/4$ absorbing structure was about 23.2 % higher than that of absence absorbing structure.

증착조건 및 열처리 온도에 따른 유기 TFT의 활성층용 펜타센 박막의 전기적 특성 연구 (The Electrical Characteristics of Pentacene Thin-Film for the active layer of Organic TFT deposited at the Various Evaporation conditions and the Annealing Temperatures)

  • 구본원;정민경;김도현;송정근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.80-83
    • /
    • 2000
  • 본 연구에서는 유기물 전자소자 개발을 위한 기초 연구로서 증착시 기판의 온도, 증칙비, 열처리 온도에 따른 펜타신 박막의 수평방향 전기전도도, 접촉저항, 면저항 둥 전기적 특성을 측정 하였다. 시료는 분말형 펜타신을 유기분자선 성막장치(OMBD)를 이용하여 성막 하였다. 전도도 계산을 위한 두께의 측정은 $\alpha$-step을 이용하였으며, TLM(transfer length method)으로 접촉저항, 면저항등 전기적 특성을 측정하였다. 전극은 Au를 사용하여 진공 증착법으로 제작하였다. 기판의 온도는 3$0^{\circ}C$, 4$0^{\circ}C$, 5$0^{\circ}C$, 6$0^{\circ}C$, 7$0^{\circ}C$, 8$0^{\circ}C$, 10$0^{\circ}C$ 일곱 종류로 하여 증착비를 달리 하였고, 열처리에 의한 효과는 10$0^{\circ}C$에서 증착한 시료를 10$0^{\circ}C$, 14$0^{\circ}C$에서 각각 10초간 열처리를 실시하였다. 기판 온도에 따른 막의 형상은 AFM을 이용하여 관찰하였다. 기판의 온도가 상승할수록 박막의 결정화가 활발히 진행되었으며 최대단일결정은 4$\mu\textrm{m}$였다. 전기전도도는 7.40$\times$$10^{-7}$ S/cm ~ 0.778$\times$$10^{-5}$ S/cm의 값을 나타내었으며, 접족저항은 10$0^{\circ}C$에서 증착하고 14$0^{\circ}C$에서 10초간 열처리 한 경우 2.5324㏁으로 가장 작았으며, 면저항은 약간의 차이는 있으나 전체적으로 ≒ $10^{9}$ Ω/ 의 값을 보였다

  • PDF