• Title/Summary/Keyword: Electrical and electronic equipments

Search Result 192, Processing Time 0.024 seconds

A Study on Electric Conduction Characteristic in the Glass Transition Point of electric Power Equipments Cross - Linked Polyethylene (전력설비용 가교 Polyethlene의 Glass 전이점에서의 전기전도 특성에 관한 연구)

  • 김강원;서장수;김병인;국상훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.64-68
    • /
    • 1991
  • It happened that there was a sudden peak with the capacity of change, when I measured the capacity of change, cubical expansion and Thermally Stimulated Current on the Cross - Linked Polythylene. Crystal melting began at 375 K and changed into formaless shapeless at 380 K. The conduct of a particle on the surfase of dipole, electron trap was founded to be ion conduction nature under the low electronic field, wherase, the electron nature under the high electronic field. Consequentity, under the semi-conduction layer electronic a particle was injected to inter-fase and accumulated for a time and appeared to be TSC.

  • PDF

Implementation of A Web-based Virtual Laboratory For Electronic Circuits Using Java Applets (자바 애플릿을 이용한 웹기반 전자회로 가상실험실의 구현)

  • Kim, Dong-Sik;Choi, Kwan-Sun;Lee, Sun-Heum;Seo, Sam-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2625-2627
    • /
    • 2002
  • A virtual laboratory for measurement and instrumentation must aim to realize an integrated environment. To achieve this goal, we designed and implemented a client/server distributed environment and developed a web-based virtual laboratory system for electronic circuits. The proposed virtual laboratory system is composed of four important components : Principle Classroom, Virtual Experiment Classroom, Evaluation Classroom and Overall Management System. Through our virtual laboratory, the learners will be capable of learning the concepts and theories related to electronic circuit experiments and how to operate the experimental equipments. Also, every activity occurred in our virtual laboratory is recorded on database and printed out on the preliminary report form. All of these can be achieved by the aid of the Management System. The database connectivity is made by PHP and the virtual laboratory environment is set up slightly differently for each learner. Finally, we have obtained several affirmative effects such as reducing the total experimental hours and the damage rate for experimental equipments and increasing learning efficiencies as well as faculty productivity.

  • PDF

Half-Bridge Resonant Converter with Coreless Isolation Transformer (공심 절연변압기를 구비한 반브릿지 공진형 컨버터)

  • Heo, Joon;Jeon, Seong-Jeub
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.636-642
    • /
    • 2017
  • Recently, new power devices, SiC and GaN FETs, are commercialized. They are expected to change power electronics environments. They will raise operating frequencies of power electronic equipments. Accordingly, design method will be changed greatly. In this paper, an 1 MHz resonant converter with fully compensated coreless isolation transformer is proposed, where the primary voltage is proportional to the secondary current and the primary current to the secondary voltage. 30 W prototype is constructed and tested, and its usefulness is verified.

Technological and Theoretical Relationship between Wireless Power Transfer Technologies (무선전력전송기술의 기술적 이론적 상호 관계)

  • Lee, Dong-Su;Lim, Dong-Nam;Jeon, Seong-Jeub
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.245-249
    • /
    • 2014
  • Wireless power transfer (WPT) system is very attractive because it removes power cables from home appliances, office equipments and battery chargers for electric vehicles. In this paper, non-radiative WPT systems studied recently are claimed to be technologically or theoretically identical in operation irrespective of the number of coils. Especially, 2-coil and 3-coil systems are compared in detail. It is also shown that multiplicity of coils does not increase power transfer capability.

An Investigation into the Impact on Voltage Sag due to Faults in Low Voltage Power Distribution Systems

  • Aggarwal R. K.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.97-102
    • /
    • 2005
  • Voltage sags are the most widespread quality issues affecting distribution systems. This paper describes in some detail the voltage sag characteristics due to different types and locations of fault in a practical low voltage power distribution system encountered in the UK. The results not only give utility engineers very useful information when identifying parts of the system most likely to pose problems for customer equipments, but also assist the facility personnel to make decisions on purchasing power quality mitigation equipment.

A study on the converter of auxiliary power supply for electric railway vehicles (전기 철도차량용 보조전원장치의 컨버터에 관한 연구)

  • Kim, Jae-Moon;Kim, Yang-Soo;Lee, Jong-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.467-468
    • /
    • 2007
  • This paper describes characteristics of converters of auxiliary power supply for electric railway vehicles. Auxiliary power supply is called Static Inverter(SIV) which supplied lamps, air conditioning and heat equipments, control systems, etc. Simulation results shows that line No.1 cheon contains low harmonics compared with those of KTX.

  • PDF

Grounding method for Improving of the Characteristics on Cable TV Transmission Line (케이블 TV 전송선로의 특성 개선을 위한 접지방식)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Yeon, Che-Chin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

Trend for Managing Electrical Distribution Equipments Using a Wireless Sensors (배전 설비의 무선 통신을 이용한 배전 설비의 신뢰성 향상 기술 동향)

  • Lee, Ju-Hong;Yun, Ju-Ho;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.543-544
    • /
    • 2007
  • This paper introduce methods and analysis of a simple wireless sensor concept for detecting and locating faults as well as for load monitoring are presented. The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF

Insulation Design and Test of Model Windings for the Development of High Temperature Superconducting Transformer (고온초전도변압기 개발을 위한 모델 권선의 절연 설계 및 평가)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kwak, Dong-Sun;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.19-22
    • /
    • 2003
  • In the response to increasing the demands for electrical energy, much effort aimed to develop and commercialize 1MVA HTS power equipments that is supported by a grant from center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program funded by the Ministry of Science and Technology is going on in Korea. For the development, the cryogenic insulation and winding insulation of it in this paper are discussed. In the first many types of dielectric insulating tests were carried out. In detail Breakdown characteristics of $LN_2$, FRP and turn insulating films, flashover characteristics along the FRP surface in $LN_2$ were verified after distinguishing insulation components in HIS windings. And then model windings were designed and insulation test was conducted. These included a AC withstand voltage test of 50kV rms and a lightning impulse test of 150kV at peak.

  • PDF

A Study on the Protection Switching Mechanism for Distribution Automation System Ethernet Networks Service of Distribution Automation System (배전자동화시스템 통신서비스를 위한 이중화 통신망 보호절체 알고리즘 연구)

  • Yu, Nam-Cheol;Kim, Jae-Dong;Oh, Chae-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.744-749
    • /
    • 2013
  • The protection switching technology is widely adopted in the fiber-optical transmission equipments based on TDM(Time Division Multiplexing), such as PDH, SDH/SONET. A variety of protection switching algorithms for Ethernet networks and the progress of standardization are summarized in the document. There are several kinds of protection switching algorithms for Ethernet networks, such as STP, RSTP, MSTP and etc. However, since Ethernet signal move through detour route, it causes much time to recover. Accordingly, it is difficult to secure a usability of Ethernet networks and QOS(Quality of Service). Also, if the protection switching protocol standardized by IEEE and ITU-T is used, it remains a inherent network switching time for protection. Therefore, a specific protection switching algorithm for Ethernet are needed for seamless and stable operation of Ethernet networks service for Distribution Automation System(DAS). A reliable protection algorithm with no switching delay time is very important to implement Self-healing service for DAS. This study of FPGA based protection switching algorithm for Ethernet networks shows that in case of faults occurrence on distribution power network, immediate fault isolation and restoration are conducted through interaction with distribution equipments using P2P(Peer to Peer) communication for protection coordination. It is concluded that FPGA based protection switching algorithm for Ethernet networks available 0ms switching time is crucial technology to secure reliability of DAS.