• Title/Summary/Keyword: Electrical Units

Search Result 712, Processing Time 0.026 seconds

Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils (2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Chung, Soo-Bok;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.

Analysis on the Quench Characteristics According to Magnetic Field of the Matrix-Type SFCL with $1{\times}3$ Matrix Structure ($1{\times}3$ 행렬구조를 갖는 매트릭스형 초전도 한류기의 자장유무에 따른 퀜치특성 분석)

  • Oh, Kum-Gom;Cho, Yong-Sun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.343-348
    • /
    • 2008
  • We investigated the quench characteristics accordance with increase of turns and applied voltage of matrix-type superconducting fault current limiter (SFCL) with $1{\times}3$ matrixes. The matrix-type SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit fault current. The fault current limiting characteristics according to the increase of magnetic field and applied voltage were nearly same. This is because the application of magnetic field has not an affect on total impedance of SFCL. When number of turns of reactor increased, the voltage difference between two superconducting units in the current-limiting part according was decreased. The resistance difference generated in two superconducting units also was decreased. Therefore, we confirmed that the differences of critical behaviors between superconducting units by application of magnetic field were decreased. By this results, we could be decided the optimum number of turns of reactor to apply magnetic field.

A Study on Efficient Learning Units for Behavior-Recognition of People in Video (비디오에서 동체의 행위인지를 위한 효율적 학습 단위에 관한 연구)

  • Kwon, Ick-Hwan;Hadjer, Boubenna;Lee, Dohoon
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.196-204
    • /
    • 2017
  • Behavior of intelligent video surveillance system is recognized by analyzing the pattern of the object of interest by using the frame information of video inputted from the camera and analyzes the behavior. Detection of object's certain behaviors in the crowd has become a critical problem because in the event of terror strikes. Recognition of object's certain behaviors is an important but difficult problem in the area of computer vision. As the realization of big data utilizing machine learning, data mining techniques, the amount of video through the CCTV, Smart-phone and Drone's video has increased dramatically. In this paper, we propose a multiple-sliding window method to recognize the cumulative change as one piece in order to improve the accuracy of the recognition. The experimental results demonstrated the method was robust and efficient learning units in the classification of certain behaviors.

Development of a Bi-Directional Security Light Control System based on Low-Bandwidth Wireless Sensor Network (저대역 센서 네트워크 기반의 양방향 보안등 관제 시스템 개발)

  • Lee, Ho-Gun;Lee, Sang-Ho;Lee, Suk-Gyu;Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.58-66
    • /
    • 2010
  • This paper shows an implementation and management result of wireless networks based security light control system, which performs a great role in protection of pedestrians and prevention of crime. Conventional security light units have severe limits in confirmation and inspection of security light unit failure, like wilful damage by someone or failure by influence of other equipment or failure by spontaneous heat-increase, and so on. In addition, local government offices are responsible for maintenance of security light units and as a matter of fact, most of civil complaints are about security light units. It is an obvious that the existing security light maintenance system reaches the limit and the security light maintenance problem is a difficulty of local government. Therefore, efficient security light control system is needed, which enables central control and intelligent maintenance. Moreover, the system has to be easy to control and has to be stable. In this study, wireless sensor network based security light control system is implemented, which is independent of programming language and platform, and which is simple to control and extend the system. The proven protocols, HTTP and SOAP, are utilized in order to improve the system reliability. This paper shows the excellence of our proposed system by implementing and operating it in real environment.

The Probabilistic Production Simulation with Energy Limited Units Using the Mixture of Cumulants Approximation (에너지 제약을 갖는 발전기를 고려한 경우의 Mixture of Cumulants Approximation법에 의한 발전시뮬레이션에 관한 연구)

  • 송길영;김용하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1195-1202
    • /
    • 1991
  • This paper describes a newly developed method of production simulation by using the Mixture of Cumulant Approximation (MOCA). In this method, the load is modelled as random variable (r.v.) which can be interpreted in terms of partitioning the load into various categories. We can consider the load shape of multi-modal characteristics. The number of load category and demarcation points of each load category are calculated automatically by using interpolation and least square method. Each generating unit of a supply system is modelled as r.v. of unit outage capacity according to the number of unit outage subset. Since the computation burden of each subset's moments increases exponentially as units are convolved to the system, we further derive the specific recursive formulae. In simulating the energy limited units, hydro unit simulation is performed using Energy Invariance Property and the simulation of pumped storage unit is modelled as compulsory and economic operations. The proposed MOCA method is applide to the test systems and the results are compared with those of cumulant and Booth Baleriaux method. It is verified that the MOCA method is considerably reliable and stable both pathological and well behaved system.

Design of a Prototype Fibre Optic Based Monitoring and Control System for Future KEPCO's 765kV Substation (765kV 변전소 감시제어용 시범시스템)

  • Jiang, Moon-Myung;Chung, Sang-Jin;Choi, Jong-Hyoub;Park, Jong-Myung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.883-886
    • /
    • 1996
  • Instead of point-to-point hard wiring between substation yard equipments and SCADA RTU(Remote Terminal Unit), fibre optic cable will be used in the portion between Local Units and Central Unit in the future KEPCO 765kV substation. The connections between substation yard equipments and nearby Local Unit remain the same hard wiring. The new fibre optic system will provide security especially during ground faults and is immune to electrical noise. A prototype system will be manufactured and installed in the existing 154kV Yeosan Substation by the end of July this year and operated for one year. By incorporating the operation experiences acquired in the system, an improved system will be commercially applied to 765kV Shin-An-Seong Substation where 345kV GIS will be installed initially and act as the switching station in the year 1998. The system is composed of one Central Unit and several Local Units. The Central Unit is composed of two workstation level computers, one is in operation and the other backup, and a Communication Control Unit. The Local Unit uses the existing SCADA RTU technology and takes the form of a distributed one. Between the Communication Control Unit and Local Units, the fibre optic system with star-coupler is used.

  • PDF

A Study on Developing the Simulation Model of Micro-Sources (마이크로소스의 EMTDC 시뮬레이션 모델 개발에 관한 연구)

  • Son, Kwang-Myoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.24-32
    • /
    • 2005
  • Micro-source units having power ratings in thousands of watts can provide power quality with higher reliability and efficiency than the conventional large scale units. Since these units are small and easy to install, they are clustered with loads creating micro-grid services to customer sites such as office buildings, industrial parks and homes. Micro-sources adopt voltage source inverter to ensure the power quality of sensitive loads. This paper deals with the connection of micro-sources into the system grid EMTDC modeling of the grid connected micro-sources at the power frequency range are proposed and the characteristics of the control system parameters are investigated. Simulation results show that the micro-grid system with two micro-sources has good dynamic characteristics.

SIMD MAC Unit Design for Multimedia Data Processing (멀티미디어 데이터 처리에 적합한 SIMD MAC 연산기의 설계)

  • Hong, In-Pyo;Jeong, Woo-Kyong;Jeong Jae-Won;Lee Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.12
    • /
    • pp.44-55
    • /
    • 2001
  • MAC(Multiply and ACcumulate) is the core operation of multimedia data processing. Because MAC units implemented on traditional DSP units or embedded processors have latency of three cycles and cannot operate on multiple data simultaneously, then, performances are seriously limited. Many high end general purpose microprocessors have SIMD MAC unit as a functional unit. But these high end MAC units must support pipeline structure for various operation modes and high clock frequency, which makes control logic complex and increases chip area. In this paper, a 64bit SIMD MAC unit for embedded processors is designed. It is implemented to have a latency of one clock cycle to remove pipeline control logics and a minimal area overhead for SIMD support is added to existing Booth multipliers.

  • PDF

Small Nuclear Units and Distributed Resource interconnection(2) (Small Nuclear Units에 의한 분산전원 및 계통연계(2))

  • Lee, Sang-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.420-422
    • /
    • 2005
  • This paper introduces a new paradigm for energy supply system in near future which produces electric and district heat cogeneration with dispersed power grid with small nuclear power units. Recently, in nuclear field, a lot of effort has been done in nuclear major countries to develop small and medium reactor for enhancement of nuclear peaceful use as like in district heating, electric power generation, seawater desalination or hydrogen generation.

  • PDF

The Configuration of Power Demand Control System (전력수요 제어 시스템 구성 방안)

  • 송언빈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.107-110
    • /
    • 1993
  • This paper presents the technical requirements and configuration of power demand control system in office building Generally, the peak power demand is occurred in cooling period. For power demand control in existing building, the most effective control points are the motors for air handling units.

  • PDF