• 제목/요약/키워드: Electrical Transmission Characteristic

검색결과 301건 처리시간 0.026초

초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발 (The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line)

  • 주문노;양광호;이동일;신구용;임재섭
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

FDTD 수치해석에 의한 MIS transmission line의 전기적 특성 예측 (Prediction of Electrical Characteristics for MIS transmission line using FDTD Simulations)

  • 이준호;남승기;정지채
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.373-376
    • /
    • 2000
  • Coplanar-type MIS transmission lines have been simulated using FDTD method and compared with the measured results and the simulated results of the reference paper[3]. We can confirm that our simulation results are similar to measured results compared to the previous simulated results of the reference paper. Moreover, variations of characteristic impedance by insulator thickness are calculated for the insulator thickness of 0.0,0.5 and 1.0$\mu\textrm{m}$.

  • PDF

A Design Method of Lossy Linear Tapered Transmission Line with quasi Non-distortion Characteristic in the Time Domain

  • Sekine, Toshikazu;Kobayashi, Kunikatsu
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.2016-2018
    • /
    • 2002
  • An exact solution of the lossy linear tapered transmission line is derived. As its application, a simple design method of the quasi non-distortion lossy linear tapered transmission line in the time domain is described. A design example is presented to show the validity and usefulness of the method.

  • PDF

대용량 무선전력전송 환경 인근 메쉬구조 도전부 유도현상 특성 분석 (Characteristic Analysis of Induction Phenomena in the Nearby Mesh Structure Conductive Part of Large Capacity Wireless Power Transmission System)

  • 채동주;이건호;임현성;조성구
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.207-214
    • /
    • 2019
  • A large-capacity wireless power system is a technology that transmits electric power of kW or more in a noncontact type. Electric cars, electric buses, and electric railways. In order to increase the power transmission efficiency, a resonance method using a frequency of kHz is applied and the efficiency is 80 ~ 90%. In this case, the loss is 10 ~ 20% other than efficiency, and corresponds to several hundreds of W to several kW in kW class wireless power transmission. 35 kW wireless feed system environment, and induced current in the nearby conductive part was measured. As a result of analysis, it was confirmed that induction phenomenon is higher as the loop configuration of the conductive part per area is dense. The increase of the induced current in the mesh loop is characterized by the density of the nearby conductive part having a permeability per unit area. The concentration of the magnetic field by the permeability is increased and the induction phenomenon causing the induction current is increased. It was confirmed that induction phenomenon increases by about 2.7 times when 9 times dense structure is formed.

초고압 직류 송전 시스템에 대한 최적 변조 제어기의 적용 및 제어 특성에 관한 연구 (A Study on Control Characteristic and Application of Optimal Modulation Controller for HVDC Transmission System)

  • 이종민;허동렬;정동일;정형환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1318-1320
    • /
    • 1999
  • Recently, according to the growth of national economy and the improvement of lining conditions, electric power demand is increasing gradually. So it is being examined to construct large thermal power plants or nuclear plants. For the effective use of lands and for the economy of generations sites, the distance between generation and demand locations becomes farther and farther. At the same time, people desire higher quality or electric power. So in this paper, the optimal modulation controller for HVDC transmission system are designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance. It means that the application of optimal modulation controller in HVDC transmission system can contribute the propriety to the improvement of the stability in HVDC transmission system.

  • PDF

부하의 전압특성을 고려한 정량적 전압안정성 지표에 관한 연구 (A Study on the Quantatitive Voltage Stability Index Considering Load Voltage Characteristics)

  • 정준모;이봉용;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.3-5
    • /
    • 1994
  • It is shown that the power flow considering the voltage characteristic of the composite load has some difference comparing with conventional load flow in this paper. When the load flow is used in a study of the static voltage stability, it is necessary to consider the voltage characteristic of load, since the composite load of a typical power system bas constant power, constant current, and constant impedance characteristic. The load is modeled to a polynomial form in here, and used in solving the load flow problem. In this way, the effect which the voltage characteristic of the load has on several voltage collapse proximity indicator based on sensitivities is compared with the conventional load flow, or with another load model having a different voltage characteristic. In this paper, the voltage collapse proximity indicator using the sensitivity of real power for transmission loss is also proposed, and compared with other indicators.

  • PDF

345kV급 GIL이 연계된 혼합송전선로의 뇌서지해석 및 평가 (Transient Analysis and Evaluation of 345kV Combined Transmission Line Connected with GIL)

  • 장화윤;이종범;김용갑;정채균
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1949-1955
    • /
    • 2010
  • This paper describes the characteristic and effectiveness of combined GIL transmission line through lightning surge analysis. In addition the XLPE cable is analyzed in the same condition to compare with GIL. Lighting surge analysis is carried out by EMTP/ATP-Draw to obtain overvoltage of GIL and XLPE cable at service-point and load-out area of underground line. Propagation velocity is calculated in combined transmission lines with GIL and XLPE cable. The overvoltage is also analyzed on GIL and XLPE cable with or without arrester operation. The Analysis results show that overvoltage of GIL is occurred higher than XLPE cable at the same condition. Therefore it is evaluated that the application of GIL at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

Design of Planar Microwave Bandstop Filters by Control of Wave Propagation on Nonuniform Transmission Line

  • Park, Eui-Joon
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권5호
    • /
    • pp.114-120
    • /
    • 1997
  • A design method is newly presented for the creation of planar type filters which shapes will be nonuniform transmission line with continuously varying characteristic impedances. Those filters yield frequency characteristics of the bandstop filter in transmission, and have not nay discontinuities. The design is achieved by the control of wave propagation in view to both reflection an transmission properties on the dispersive nonuniform line within the desired frequency band. The developed algorithm is based on optimized perturbations of inherent nulls of lobes from the solution of first-order nonlinear differential equation for reflection coefficients of the nonuniform line, and an appropriate distribution of reflection coefficient which affects to filter length and bandwidth. Practical measurements for designed wideband microstrip and stop filter show very good agreement with theoretical results.

  • PDF

FACTS 기기가 설치된 송전선로에서 거리계전기의 응동특성 (A Study of Distance Relay Characteristic of Transmission Line including FACTS Devices)

  • 정창호;서정남;방성원;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.31-33
    • /
    • 2000
  • This paper discusses the operational characteristic analysis of distance relay depending on the power system parameters in transmission line including FACTS devices. Distance relay requires protective coordination because the FACTS devices change power system parameters to increase power transmission capacity. In this paper, the dynamic operational characteristics of distance relay are analyed for the effect of fault resistance and operation mode of FACTS devices according to the installed points of these devices.

  • PDF

DGS 구조의 4-port 등가회로 및 파라미터에 대한 추출 방법에 대한 연구 (A study for the extraction of DGS 4-port equivalent circuit and it's parameters)

  • 손창신;정명섭;최승완;박준석;임재봉;조홍구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2043-2045
    • /
    • 2004
  • This thesis complemented the weak points that the existing theses did not represented a phase characteristic as the equivalent circuit by applying 4-port simulation to DGS (Defected Ground Structure) characteristic and an equivalent circuit, which are the transmission line structure that has the defect made in the ground surface. We used a distribute device and a lumped device, obtained the equivalent circuit by applying the structure of balun to a discontinuous part. An indicated DGS (Defected Ground structure) is a dumbbells-shaped single defect, we indicated satisfying a magnitude and phase characteristics by applying this equivalent circuit.

  • PDF