• Title/Summary/Keyword: Electrical Substation System

Search Result 504, Processing Time 0.025 seconds

Implementation of Prediction Program for Deterioration Judgment on Substation Power Systems in Urban Railway (도시철도 전력설비의 노후화 판단을 위한 예측 프로그램 구현)

  • Jung, Ho-Sung;Park, Young;Kang, Hyun-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.881-885
    • /
    • 2013
  • In this paper, we present a deterioration judgment model of urban rail power equipment using driving history, the frequency and number of failures. In addition, we have developed a deterioration judgment program based on the derived failure rate. A deterioration judgment model of power equipments on metro system was designed to establish how much environmental factors, such as thermal cycling, humidity, overvoltage and partial discharge. The deterioration rate of the transformers followed the Arrhenius log life versus reciprocal Kelvin temperature (hotspot temperature) relation. The deterioration judgment program is linked to the online condition monitoring system of urban railway system. The deterioration judgment program is based on the user interface it is possible to apply immediately to the urban rail power equipment.

Development of a Digital System for Protection and Control of a Substation Part 1 - Development of hardware (변전소의 보호.제어를 위한 디지탈 시스템 개발 PART 1 - 하드웨어 개발)

  • Kwon, W.H.;Lee, Y.I.;Park, H.K.;Park, S.H.;Kim, M.J.;Moon, Y.S.;Yoon, M.C.;Kim, I.D.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.359-361
    • /
    • 1992
  • This paper describes the development of an Integrated Digital Protection And Control System (IDPACS) for 345 KV substation. The developed IDPACS system containes digital protection units for transmission lines, delivery lines, transformers, bus, shunt reactors and Shunt capacitors. We deloped a Local Area Network (LAN) Which connects the digital protection units to the station computer for monitoring and control purposes.

  • PDF

A Study on Simulation Analysis for the Transmission Delay on the Process bus network in IEC 61850 Digital Substation (디지털변전소 통합 IED 용 Process Bus 네트워크 통신지연 시뮬레이션 연구)

  • Kim, Seok-Kon;An, Yong-Ho;Jang, Byung-Tae;Choi, Jong-Kee;Lee, Nam-Ho;Han, Jung-Yeol;Lee, You-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.18-22
    • /
    • 2015
  • Digitalization of the substation in Korea has been in progress so far with focusing on Station Bus. However, its application to Process Bus has been delayed due to some technical issues. IEDs based on Process Bus use the data values of SV and GOOSE. As the size of communication data on Process Bus is comparatively bigger than that of Station Bus, it is very important for the evaluating the performance of Process Bus to analyze the transferring speed and quality of data from the first equipment, which is located on process level, to station level. According to the results of related studies, it is said that the most important factor for the design and operation of Process Bus network is the communication delay with consideration of the volume of packets. In the paper, the results of performance test for the network with and without application of VLAN on Process Bus system that uses integrated IEDs are presented. Additionally, the paper proposes the optimal method to analyze the communication delays of network systems through evaluating the maximum delay time, link process ratio and the amount of lost packets by using a simulation tool.

A Study on Digital Fault Locator for Transmission Line (송전선로용 디지털 고장점 표정장치에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

A Study on the Optimal Voltage Regulation in Distribution Systems with Dispersed Generation Systems (분산형전원이 도입된 배전계통의 최적전압조정 방안에 관한 연구)

  • Kim Mi-Young;Oh Yong-Taek;An Jae-Yun;Kim Jae-Eon;Kim Eung_Sang;Rho Dae-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.251-258
    • /
    • 2005
  • Recently, the domestic and foreign power trends are the supply of high quality power and environment conservation technology based on the new energies development. So, the dispersed generation systems, such as photovoltaic, fuel cell, and battery are to be introduced in distribution systems. According to the situation change, power of high Quality and reliability are required in distribution systems with dispersed generation. Up to now, the voltage in distribution systems are regulated by ULTC of substation and pole transformer of primary feeders. These days, Step Voltage Regulator(SVR) is getting established at distribution feeders to regulate effectively voltage of primary ffeders that voltage drop exceeds $5\%$. But, because SVR is operated independently with ULTC of substation, SVR can not take play to its full effectivity. Under these circumstances, in order to deliver suitable voltages to as many customers as possible, new optimal voltage regulation algorithms are required in distribution system. So, this paper presents optimal voltage regulation algorithm to regulate voltage effectively for ULTC and SVR in distribution systems with dispersed generation systems.

A Study on the State Estimation for Distribution Substations (변전소 상태변수 추정에 관한 연구)

  • 이흥재;박성민;이경섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.103-109
    • /
    • 2003
  • The validity of measured data is fundamental factor for the power system automation Measured values could have errors that are caused by the communication errors and malfunctioning measuring devices. The accuracy and reliability of measured values at a substation is an important condition for robust and fault tolerant automata. Errors can be reduced by state estimation, however, global reliability of state estimation goes down in case of the existence of some bad data In this paper, a least square state estimation and bad sensor detection algorithm based on chi-square theory, ale proposed and it is applied to a domestic 154kV distribution substations. A simulator together with user friendly graphic users interface is developed using C language and Visual Basic. TCP/IP is equipped for future connection with other operation systems.

Power Quality Analysis of Wind Farms interconnected in Jeju System during HVDC Overhaul (HVDC Overhaul 기간 중 제주계통에 연계된 풍력발전의 전력품질 분석)

  • Chae, Woo-Kyu;Yoon, Gi-Gab;Cho, Seong-Soo;Jung, Won-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1946-1953
    • /
    • 2008
  • Power system of Jeju is interconnected to the mainland using HVDC and that is also interconnected to three wind farms. It will be difficult to control of Jeju power system if HVDC is disconnected or HVDC is overhauled under large scale wind farms interconnected. We measured and analysed the power quality of two substation and two wind farms to assess that wind farms have an effect on Jeju system during the HVDC overhaul last May. We concentrated on the power quality like frequency, voltage variation, voltage harmonics, current harmonics, flicker. We can found that the frequency of Jeju system is very unstable during overhaul, so the frequency of Jeju system can be variated easily by wind farm's rapid output power variation. There are some benefits and weak points in power quality between two wind farms because each wind farm is consist of different wind turbines.

Inspection On Sensors of Online Preventive diagnostic system Sensors for Power Transformer (변압기 온라인 예방진단 센서의 점검현황)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Kang, Yeon-Woog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.455-460
    • /
    • 2005
  • Preventive diagnostic system for power transformer prevents the sudden power failure through monitoring of abnormal symptoms. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data accumulated in a server computer is very important. Therefore, this paper describes problem when apply system to substation and solution way to improve reliability of the system

  • PDF

An Adaptive Genetic Algorithm Based Optimal Feeder Routing for Distribution System Planning (적응 유전알고리즘을 이용한 배전계통 계획의 급전선 최적경로 선정)

  • Kim, Byung-Seop;Kim, Min-Soo;Shin, Joong-rin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.58-66
    • /
    • 2001
  • This paper presents an application of a newly designed Adaptive Genetic Algorithm (AGA) to solve the Optimal Feeder Routing (OFR) problem for distribution system planning. The main objective of the OFR problem usually is to minimize the total cost that is the sum of investment costs and system operation costs. We propose a properly designed AGA, in this paper, which can handle the horizon-year expansion planning problem of power distribution network in which the location of substation candidates, the location and amount of forecasted demands are given. In the proposed AGA, we applied adaptive operators using specially designed adaptive probabilities. we also a Simplified Load Flow (SLF) technique for radial networks to improve a searching efficiency of AGA. The proposed algorithm has been evaluated with the practical 32, 69 bus test system to show favorable performance. It is also shown that the proposed method for the OFR can also be used for the network reconfiguration problem in distribution system.

  • PDF

Development of Condition Monitering Technology for Railway Electrification System (철도 전기시설물의 상태진단 향상 기법)

  • Park, Young;Jung, Ho-Sung;Kim, Hyung-Chul;Kewon, Sam-Young;Park, Hyun-June
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.500-501
    • /
    • 2007
  • Automation systems for higher performance and efficiency in railway electrification systems are driving ever more demanding needs for new condition monitering systems which can consist of sensors connected to the substation and catenary systems. This paper reviews the recently developed condition monitering system, based on a IP network-based multi-agent system, wireless communications and sensor networks for railway electrification system. A new concept for information management, condition monitoring and control of power transmission are considered as railway automation in electrification system.

  • PDF