• Title/Summary/Keyword: Electrical Safety Management

Search Result 297, Processing Time 0.027 seconds

The Efficiency Improvement of Flocculation Facilities in Water Treatment Plants (정수장 응집설비의 효율증대 방안연구)

  • Jeon, Bok-Su;Lee, Eun-Woong;Lim, Su-Saemg;Choi, Jae-Young;Kim, Hong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.952-954
    • /
    • 2000
  • In the cleaning-water treatment process, the flocculation machine is operated by the V.S motor when the coagulation-facility of the coagulation-process is operated. But after the flocculation machine is stopped by an instantaneous power failure, the transient takes place when the coagulation facility is re-started. To improve the transient state, we developed the reinforcement-circuit which had the function of soft-start and adapted to the field. As a result of this study, we reduced the damage of facilities and had the safety in maintaining the quality of water and improved the efficiency in the maintenance and the management.

  • PDF

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

Battery Response Characteristics According to System Modeling and Driving Environment of Electric Vehicles (전기자동차 시스템 모델링 및 주행 환경에 따른 배터리 응답 특성 연구)

  • Chu, Yong-Ju;Park, Jun-Young;Park, Gwang-Min;Lee, Seung-Yop
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.2
    • /
    • pp.85-92
    • /
    • 2022
  • Currently, various researches on electric vehicle battery systems have been conducted from the viewpoint of safety and performance for SoC, SoH, etc. However, it is difficult to build a precise electrical model of a battery system based on the chemical reaction and SoC prediction. Experimental measurements and predictions of the battery SoC were usually performed using dynamometers. In this paper, we construct a simulation model of an electric vehicle system using Matlab Simulink, and confirm the response characteristics based on the vehicle test driving profiles. In addition, we show that it is possible to derive the correlation between the SoC, voltage, and current of the battery according to the driving time of the electric vehicle in conjunction with the BMS model.

High-radiation-exposure work in Korean pressurized water reactors

  • Changju Song;Tae Young Kong;Seongjun Kim;Jinho Son;Hwapyoung Kim;Jiung Kim;Jaeok Park;Hee Geun Kim;Yongkwon Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1874-1879
    • /
    • 2024
  • Owing to strict radiation safety management in Korean nuclear power plants (NPPs), most radiation workers receive very low radiation doses, even lower than the annual dose limit for the general public. However, the occupational dose distribution indicates that some Korean NPP workers receive a relatively higher dose than the average dose. This inequity in radiation exposure could be reduced by providing customized radiation protection measures, such as dose constraints, to workers receiving relatively higher doses. In this study, dose normalization was performed to identify the highest radiation exposure work in Korean pressurized water reactors (PWRs). The results show that most of the occupational exposure in Korean PWRs occurs during the planned maintenance period. Finally, the three highest radiation exposure tasks in Korean PWRs were identified: nozzle dam installation and removal, eddy current testing, and man-way opening and closing.

Personalized Cooling Management System with Thermal Imaging Camera (열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.782-785
    • /
    • 2021
  • In this paper, we propose a personalized cooling management system with thermal imaging camera. The proposed equipment uses a thermal imaging camera to control the amount of cold air and the system according to the difference between the user's skin temperature before and after the procedure. When the skin temperature is abnormally low, the cold air supply is cut off to prevent the possibility of a safety accident. It is economical by replacing the skin temperature sensor with a thermal imaging camera temperature measurement, and it can be visualized because the temperature can be checked with the thermal image. In addition, the proposed equipment improves the sensitivity of the sensor that measures the distance to the skin by calculating the focal length by using a dual laser pointer for the safety of a personalized cooling management system to which a thermal imaging camera is applied. In order to evaluate the performance of the proposed equipment, it was tested in an externally accredited testing institute. The first measured temperature range was -100℃~-160℃, indicating a wider temperature range than -150~-160℃(cryo generation/USA), which is the highest level currently used in the field. In addition, the error was measured to be ±3.2%~±3.5%, which showed better results than ±5%(CRYOTOP/China), which is the highest level currently used in the field. The second measured distance accuracy was measured as below ±4.0%, which was superior to ±5%(CRYOTOP/China), which is the highest level currently used in the field. Third, the nitrogen consumption was confirmed to be less than 0.15 L/min at the maximum, which was superior to the highest level of 6 L/min(POLAR BEAR/USA) currently used in the field. Therefore, it was determined that the performance of the personalized cooling management system applied with the thermal imaging camera proposed in this paper was excellent.

Proper Monitoring Methods for Safety Management of Tailings Dam (광물찌꺼기적치장의 안전관리를 위한 적정 모니터링 방안 연구)

  • Jung, Myung Chae;Kim, Jeong Wook;Hwang, In-ho;Yang, In Jae;Park, Jay Hyun;Park, Ju Hyun;Kim, Tae Youp
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.576-587
    • /
    • 2018
  • This study has focused on analysis factors affecting safety monitoring system at tailings sites, and the evaluation equipment to monitor the factors. Twenty sites at eighteen mines with unsafe conditions were selected to examine the equipment. There were three main factors influenced safety in the sites including surface erosion, piping, and slope instability. In detail, the surface erosion was divided into three sub-factors (planting, soil-topping layer, and tailings), piping into three sub-factors (liner, rain protection facility and leachate), and slop instability was also divided into three sub-factors (slop, concrete wall, and reinforcing wall). As results of in-field measurement, a CCTV was the most effective facility, and electrical resistivity survey, acoustic sensing, thermal liner sensor, structure inclinometer, rainfall meter, and flowmeter were also highly effective. According to applications of the facilities in the unstable tailings, structural defects were mainly found in the piping, which was the most important monitoring factor for safety management of tailings sites.

PV Inverter Operation according to DC Capacitor Aging (직류 커패시터 노후화에 따른 PV 인버터 동작)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.149-155
    • /
    • 2023
  • Photovoltaic power generation is the most familiar power generation facility among new and renewable energies, and its supply began to expand about 10 years ago, and at this point, interest in solutions and technologies for system maintenance management is increasing. In particular, it is necessary to take measures to maximize the overall efficiency of the solar power generation system, whether or not there is an abnormality in the solar power generation system, and when to replace parts. The PV inverter, one element of the photovoltaic power generation system, is a power conversion system that relies on power switching devices, and DC-Link capacitors are used according to the configuration of DC/DC converters and DC-AC inverters. These DC capacitors also affect system safety (Safety) through renewable energy facilities due to the decrease in power generation of PV inverters, power loss, and increase in harmonics (THD, total distortion of AC output current) due to aging and deterioration due to long-term use. factors can be analyzed. Therefore, in this paper, the PV inverter operating characteristics according to the DC capacitor capacity state currently operating in the photovoltaic power generation system were considered, and research contents were proposed to secure the safety and reliability of renewable energy facilities.

Analysis of Electrical Resistivity Change in Piping Simulation of a Fill Dam (필댐의 파이핑 재현시험시 전기비저항 변화 분석)

  • Ahn, Hee-Bok;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.4
    • /
    • pp.59-68
    • /
    • 2010
  • Piping, a common form of internal embankment erosion, is caused by progressive movement of soil particles through an embankment. The phenomenon commonly occurs with precursory signs of development of fractures in dam structures, but also occurs without any noticeable signs in dams that showed satisfactory dam performance for several years, due to dissolution of soluble material in an embankment. While piping accounts for nearly 50% of the causes for dam failure, few studies have been made for systematic evaluation of the phenomenon. In this study, we attempted to monitor the changes in electrical resistivities of fill-dam material while a saddle dam is dismantled for the construction of emergency spillways of Daechung dam. Two artificial subhorizontal boreholes were drilled into the embankment structure to simulate piping along the two artificial flow channels. Monitoring of changes in electrical resistivity showed an increase in resistivity values during piping. Thus, the investigation of resistivity over time could be an effective method for piping prediction.

An Efficient Dynamic Workload Balancing Strategy Design of the Wireless Reading/Management System for the Corrosion Monitoring of Underground Structures (지하 구조물 부식 감시를 위한 무선 검침/관리 시스템 설계)

  • Kwan, Yong-Kwang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.7
    • /
    • pp.95-102
    • /
    • 2014
  • There are a variety of structures below the surface are buried. In particular, if It is experiencing problems in the city gas pipe or electrical wire, our safety would be greatly jeopardized. Therefore, the underground structures which encounter a variety of pollutants are highly sensitive to corrosion. So if you are not identify the degree of corrosion, it can lead to large accidents such as gas leakage. Until now, person visit directly every underground structure to measure and record manually, but This approach requires a lot of human and material resources and the continuity of management. Therefore, the research to find out the risk factors quickly via the continuous management is needed, and in this paper the structures management systems in the vehicle being moved by combining ICT underground structures for state information wirelessly collects and analyzes system is proposed.

A Study on the Fabrication of Multi-Walled Nanotubes (MWCNT) Based Thin Film and Chemical Sensor Operation Characteristics (Multi-Walled Carbon Nanotubes (MWCNT) 인쇄박막의 제작과 화학센서 동작 특성에 관한 연구)

  • Noh, Jae Ha;Choi, Junseck;Ko, Dongwan;Seo, Joonyoung;Lee, Sangtae;Jung, Jung-Yeul;Chang, Jiho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.181-185
    • /
    • 2020
  • Hazardous and noxious substance (HNS) detection sensors were fabricated using multi-walled carbon nanotubes (MWCNTs) and various binder materials for ion batteries. To obtain uniformly printed films, the printing precision according to the substrate cleaning method was monitored, and the printing paste mixing ratio was investigated. Binders were prepared using styrene butadiene rubber + carboxymethyl cellulose (SBR+CMC), polyvinylidene fluoride + n-methyl-2-pyrrolidene (PVDF+NMP), and mixed with MWCNTs. The surface morphology of the printed films was examined using an optical microscope and a scanning electron microscope, and their electrical properties are investigated using an I-V sourcemeter. Finally, sensing properties of MWCNT printed films were measured according to changes in the concentration of the chemical under the various applied voltages. In conclusion, the MWCNT printed films made of (SBR+CMC) were found to be feasible for application to the detection of hazardous and noxious chemicals spilled in seawater.