• Title/Summary/Keyword: Electrical Safety Management

Search Result 299, Processing Time 0.032 seconds

A Study on the Utilization of QR Code for Improving the Effectiveness of Safety Education in Power Plant Workplaces (발전소 사업장의 안전교육 효과성 향상을 위한 QR Code 활용방안 연구)

  • Oh, Myeong-Geun;Kim, Young-Kook;Jeong, Kyung-Ok
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.33-39
    • /
    • 2022
  • In order to improve the implementation of safety and health education at the site for industrial accident prevention activities, research was conducted to minimize inconvenience and increase utilization by redesigning and developing existing education methods. To date, occupational safety and health education has been conducted without considering the general work characteristics and functional facilities (mechanical, electrical, instrumentation, chemical) of workers (mechanical: turbine, valve, pump, hydraulic system, electrical: generator, breaker, motor, etc.). In particular, plant facilities were classified as mechanical and electrical facilities to improve the methodology for industrial safety and health education for plant maintenance workers. In addition, the "One Page Education Plan" was announced as a learning case because the spread of COVID-19 infectious diseases made it impossible to reduce or control the number of people in all groups and groups. The improvement of this training method will play a major role in improving the effectiveness of safety education in power plant workplaces.

A statistics and study of fire cause by electrics (전기로 인한 화재 원인 통계와 고찰)

  • Lee, Young-Soo;Kim, Myeong-Soo;Hawng, Byung-Pyo;Kim, Hyeong-Soo;Song, Young-Hak
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.47-57
    • /
    • 2007
  • If it were the occurrence of fire by electricity with the rapid growth of economy, it would be serious damage for nation that effect human life and properties. To prevent electrical fires, it was basic countermeasure that make detail statistics classified by the source, place etc. with examining correct cause of fire. In this paper, we analuzed the present condition of fire occurrence of the lastest ten years and classified fires by the source, place, month in 2006. In addition our corporation staff execute in-depth and professional research on the actual state of electrics fire by visiting fire stations fire of the whole country for 8,554 electric fires in 2005. I expect this thesis to be used for preventing electric fires and providing a stepping stone on correct production of fire statistics.

  • PDF

A Management of Child Care Facility for Electrical Safety using Home-Smart Cabinet Panel(H-SCP) (지능형 홈 분전반을 이용한 영유아 시설 전기 안전 관리)

  • Ahn, Jae-Min;Lim, Young-Bae;Bae, Seok-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2144-2145
    • /
    • 2011
  • We carry out a demonstration project to verify performance of a Home- Smart Cabinet Panel(H-SCP) at the child care facility. It is difficult to prevent an electrical disaster using a existing cabinet panel because electrical events are invisible and unforeseeable. So we construct a integrated information system with a Home-Smart Cabinet Panel(H-SCP) for management of low-voltage customers. The integrated information system with the H-SCP maintain the transmitted data from H-SCP, alert a electrical event to a administrator and show a state of customer health in real time respectively. A manager of electrical safety can prevent electrical disaster to maintain electrical facilities after analysis on the integrated information system.

  • PDF

On Improving the Electrical Safety Systems based on the Systems Engineering Method (시스템 공학 기법에 의한 전기안전시스템 체계 개선에 관한 연구)

  • Shin, Heung-Sik;Lee, Jae-Chon;Lee, Byoung-Gil
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.6
    • /
    • pp.39-46
    • /
    • 2007
  • In this paper we discuss the problems related with the existing electrical safety system that is influenced by all the socio-technical factors including the electrical safety law, government organizations, and their practicing rules and regulations. Sometimes intangible practices also affect the safety issues. It is our intention to incorporate all those factors effectively and systematically in improving the electrical safety system. Since, the problem in nature is so complex, an approach based on the systems engineering (SE) method could be a good candidate. Specifically, as a first step of the SE process we performed the requirements analysis of all the factors mentioned above and some recommendations from the experts in the field. In the work environment utilizing a computer-aided SE tool, the requirements are verified and managed efficiently although the data base is complicated in general in tracking the changes. Next, by analyzing the verified requirements, a functional architecture is developed to achieve an improved electrical safety system. We also did the reverse engineering of the existing electrical safety system to explore potential problems there. The result can also help improve the existing one. Overall, a systematic approach to constructing electrical safety system based on SE is proposed for the first time in this paper. Note that the method described here can be adopted in the study of other safety systems.

A Study on Arc Fault Detection Algorithm Based on Mash-up Analysis Technique (Mash-up 분석기술 기반의 아크 고장 검출 알고리즘에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bea;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.995-1000
    • /
    • 2017
  • In this paper, we present an electrical arc detection algorithm using the mash-up analysis technique which is the core technology for the autonomous electrical safety management system(AESMS) of the multi-unit dwellings. The mash-up analysis technique analyzes the voltage, load current, zero phase current data simultaneously to judge arc faults. In order to develop the arc fault detection algorithm, the characteristics of series arc and parallel arc were analyzed. Also, we propose the mash-up analysis technique that analyzes waveforms of voltage, load current, and zero phase current at the same time. The arc fault detection algorithm was developed using the mash-up analysis technique. The developed algorithm can prevent electrical disasters in an effective way through accident prediction, and it will be used as a basic technology to introduce an autonomous electrical safety management system.

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.

A Study on the Safety Checking and Testing method of the underground power transmission line (OF Cable) (지중송전선로 안전관리 방안 (OF케이블))

  • Choi, Jong-Soo;Park, Kang-Seo;Jeon, Jun-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.429-434
    • /
    • 2009
  • In this paper it was written about the safety management plan for underground power transmission cable, and it guarantees the reliable electric power supply and facility management to prevent an electric disasters according to that. Recently fires which happens on OF Cable lead to a breakdown of power system and cause a power outage of wide area and serious social problems. So it needs an improvement of inspection ability on OF cable as well as a strict inspection system to prevent that problems in advance and it will bring us the development of electric safety management and the reliable electric power supply.

  • PDF

Analysis of Insulation Resistance Change according to the Installation Environment of Food Manufacturing Electrical Equipment (식료품 제조업 전기설비의 설치환경에 따른 절연저항 변화 분석)

  • Youn Su Jeong;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2023
  • In this study, S food manufacturing business located in Chungbuk was selected as the subject, and the transition in insulation resistance in major electrical equipment used in this food manufacturing business was analyzed for 4 years (2018-2021). It was confirmed that the insulation resistance decreased over time for all 18 electrical facilities. Insulation resistance changed due to environmental influences such as load characteristics and ambient temperature. Particularly in the case of the food manufacturing industry, it was confirmed that the decrease started after 2 years, although it varied depending on equipment and environmental influences. Furthermore, it was confirmed that management through predicting the management cycle of electrical equipment is possible by deriving a regression equation through regression analysis of insulation resistance measurement values.

A Study on the Reconfiguration in the Regulation of Electric Safety Management for the Guarantee of Safety (안전성 확보를 위한 전기안전관리기준의 재설정에 관한 연구)

  • Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.45-49
    • /
    • 2009
  • This study is to prepare a reasonable basis for the improvement of the electrical safety management regulation. The standards in domestic and foreign countries for the application of new and renewable energy facilities and other devices are analyzed. Other regulations excluding the electrical safety fields and wide surveys are also carried out. Consequently, it is asked that the classification between normal and self electrical facilities should be clear and deregulation for small businesses has to be followed. This study is showed that standards investigates of receiving equipment below 600V above 75kW, eletrical safety manager employment of manufacturing industry and Mid-night electric power. And, it is showed that consignment permission and Consignment inspection periodic relaxation about wind development equipment below 1,000kW, consignment of Technical Development equipment for new and renewable energy below 250kW.

Analysis of the Status of Safety Management of Photovoltaic Power Generation Facilities (태양광발전설비 안전관리 현황 분석)

  • Kim, Wan-su;Park, Sang-June;An, Seong-ryeol
    • Current Photovoltaic Research
    • /
    • v.7 no.2
    • /
    • pp.38-45
    • /
    • 2019
  • In this paper, we analyzed the present status of the safety manager and safety assurance aspects through a complex analysis on the operational aspects, marketability and electrical safety aspects of photovoltaic power generation facilities. In the analysis of the equipment status, we analyzed the status and operated status of the installed PV system in Korea and the correlation between the safety manager and the accident. In addition, we analyzed the direction of the ESS through the analysis of the installation status of the ESS, and applied it to the interpretation part of the ESS associated with the solar power generation. The status of the electric safety manager can be used to analyze the data for selecting the electric safety manager by capacity by analyzing the accident status, the electric safety manager operation status, the safety management time by capacity, and the electric safety manager market.