• Title/Summary/Keyword: Electrical Safety Management

Search Result 295, Processing Time 0.024 seconds

Case Study on the Assessment of SIL Using FMEDA (FMEDA 기법을 적용한 SIL 등급 판정에 관한 사례연구)

  • Kim, Byung Chul;Kim, Young Jin
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.376-381
    • /
    • 2012
  • As the number, complexity and interaction of electrical, electronic and programmable electronic (E/E/PE) systems increase, a growing emphasis has been placed on the concept of functional safety during product development. IEC 61508 provides guidelines and standardized procedures in the development of reliable and dependable E/E/PE systems to assure functional safety. Determining risk classes (i.e., safety integrity levels, SILs) associated to a specific E/E/PE item may be recognized as one of the most crucial activities in the product development per IEC 61508 since SILs are used to specify necessary safety requirements for achieving an acceptable residual risk. This article presents a case study on the assessment of SILs applying failure modes, effects and diagnostic analysis (FMEDA) from which failure rates may be derived for each important failure category by combining a standard FMEA with online diagnostic techniques.

Development of a Novel Real-Time Monitoring System Algorithm for Fire Prevention (화재예방을 위한 실시간 모니터링 시스템의 알고리즘 개발)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.47-53
    • /
    • 2014
  • Despite the automatic fire alarm system, according to the national fire data system of national emergency management agency, the fires account for 40,932 incidents, 2,184 injuries and about 430 billion won in property losses in 2013. Since the conventional automatic fire alarm system has several weaknesses related to electrical signal such as noise, surge, lighting, etc. Most fires are mainly caused by electrical faults, mechanical problem, chemical, carelessness and natural. The electrical faults such as line to ground fault, line to line fault, electrical leakage and arc are one of the major problems in fire. This paper describes the development of a novel real-time fire monitoring system algorithm including fault detection function which puts the existing optic smoke and heat detectors for fire detection with current and voltage sensors in order to utility fault monitoring using high accuracy DAQ measurement system with LabVIEW program. The fire detection and electrical fault monitoring with a proposed a new detection algorithm are implemented under several test. The fire detection and monitoring system operates according to the proposed algorithm well.

A Study on safety against a fire of charging cable for mobile phone for vehicle (자동차용 모바일 폰 충전 케이블의 발화 안전성에 관한 연구)

  • Kwon, Jin-Wook;Choi, Kyu-Sik;Hwang, Myung-Whan
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition $25^{\circ}C$, 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.

Case Study on AUTOSAR Software Functional Safety Mechanism Design: Shift-by-Wire System (AUTOSAR 소프트웨어 기능안전 메커니즘 설계 사례연구: Shift-by-Wire 시스템)

  • Kum, Daehyun;Kwon, Soohyeon;Lee, Jaeseong;Lee, Seonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.6
    • /
    • pp.267-276
    • /
    • 2021
  • The automotive industry and academic research have been continuously conducting research on standardization such as AUTOSAR (AUTomotive Open System ARchitecture) and ISO26262 to solve problems such as safety and efficiency caused by the complexity of electric/electronic architecture of automotive. AUTOSAR is an automotive standard software platform that has a layered structure independent of MCU (Micro Controller Unit) hardware, and improves product reliability through software modularity and reusability. And, ISO26262, an international standard for automotive functional safety and suggests a method to minimize errors in automotive ECU (Electronic Control Unit)s by defining the development process and results for the entire life cycle of automotive electrical/electronic systems. These design methods are variously applied in representative automotive safety-critical systems. However, since the functional and safety requirements are different according to the characteristics of the safety-critical system, it is essential to research the AUTOSAR functional safety design method specialized for each application domain. In this paper, a software functional safety mechanism design method using AUTOSAR is proposed, and a new failure management framework is proposed to ensure the high reliability of the product. The AUTOSAR functional safety mechanism consists of memory partitioning protection, timing monitoring protection, and end-to-end protection. The fault management framework is composed of several safety SWCs to maintain the minimum function and performance even if a fault occurs during the operation of a safety-critical system. Finally, the proposed method is applied to the Shift-by-Wire system design to prove the validity of the proposed method.

Efficient Approaches of Functional Safety for Medical Equipment using Essential Performance Analysis (필수성능 분석을 통한 효율적인 의료기기 기능안전 접근 방안)

  • Kim, Gi-Young;Yoo, Ki-Hoon;Park, Ho-Joon;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.15 no.1
    • /
    • pp.27-32
    • /
    • 2015
  • Functional safety is part of the overall safety relating to the equipment under control (EUC) and the EUC control system that depends on the correct functioning of the electrical/electronic/programmable electronic (E/E/PE) safety-related systems. Since the complexity of the medical equipment is increased, manufactures have to obtain functional safety as well as basic safety. This study proposes a perspective for applying functional safety to medical equipment. The research is carried out with respect to overall safety life-cycle of functional safety and essential performance of the medical equipment. The relationship between functional safety and essential performance is identified centered on the safety function. The essential performance using E/E/PE systems is defined as a safety function of functional safety. This approach is applied to a ultrasound imaging system as a case study.

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

ISO 26262 automotive functional safety: issues and challenges

  • Ismail, Azianti;Liu, Qiang
    • International Journal of Reliability and Applications
    • /
    • v.15 no.2
    • /
    • pp.151-161
    • /
    • 2014
  • Recently, the automotive industry has been introduced to ISO 26262 in November 2011 to address the necessity of safety risk from sensor to actuator by providing guidance in the form of requirements and processes. The malfunctioning behaviour of these systems could have significant impact on the safety of humans and/or the environment. Most of the modern automobiles are equipped with embedded electronic systems which include lots of Electronic Controller Units (ECUs), electronic sensors, signals, bus systems and coding. Due to the complex application in electrical, electronics and programmable electronics, the need to carry out detailed safety analyses which focuses on the potential risk of malfunction is crucial for automotive systems. In this paper, the international trends on pre and post introduction of ISO 26262 through publications will be analyzed as well as to take a glimpse in the activities for implementing this standard by the automotive manufacturers. The issues and challenges which have been occurring from implementing this standard also will be highlighted.

  • PDF

Method for High-visibility of Online Monitoring and Fault Diagnosis System for Industrial Motor using PVA (PVA를 이용한 산업용 모터 고장진단 모니터링 시스템의 가시성을 높이는 방법)

  • Goh, Yeong-Jin;Kang, In-Won
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial Motors diagnostic equipment is highly dependent on the automation system, so if there are defects in the automation equipment, it can only rely on the operator's intuitive judgment.To help with intuitive judgment, Park's Vactor Approach(PVA) represents the current signal as a pattern of circles, so it can tell if a fault occurs when the circle is distorted. However, the failure to judge the degree of distortion of the circle pattern is the basis of the fault, so it will face difficulties. In this paper, in order to compare the faults of PVA, the period of d-axis current of PVA pulsation was mastered, so that two phase differences occurred in the same signal source. Through experiments, it is confirmed that this is a 90 degree cross formation of PVA, which is convenient for judging from the vision that there is no fault, thus helping the operator to make intuitive judgment.

Study of the Risk of Ignition due to Internal Combustion Engines in Areas with Potentially Explosive Gas Atmospheres (잠재적 폭발위험장소에서 내연기관에 의한 점화 위험성에 관한 연구)

  • Kim, Yun Seok;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.1-8
    • /
    • 2016
  • Safety management in hazardous areas with potentially explosive gas atmospheres (here in after referred to as hazardous areas) in large scale facilities dealing with combustible or flammable materials at home and abroad is very important (significant) for the coexistence of the company and local society based on business continuity management (BCM) and reliance. For the safety management in hazardous areas, two systems are mainly used: (1) the control system for the prevention of combustible or flammable substances and (2) the explosion proof system for the elimination of ignition sources when flammable gases are leaked to inhibit the transition to fire or explosion accidents. While technology and regulations on explosion proof facilities or devices for electrical ignition sources are well developed and defined, those for thermal ignition sources need to be more developed and established. In this study, the internal combustion engine in hazardous areas was investigated to determine the risk of ignition. For this purpose, document searches were conducted on the relevant international standards and accidents cases and risk analysis reports. In addition, this study assessed the application cases of the diesel engine's safety equipment, such as spark arresters regarding the site of process safety management (PSM) system in central Korea. To practically apply these results to the hydrocarbon industry, the safety management method for explosion prevention in hazardous areas was provided by risk identification for ignition sources of internal combustion engines, such as diesel engines.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.