• Title/Summary/Keyword: Electrical Pole

Search Result 1,094, Processing Time 0.039 seconds

Implementation of Evolving Neural Network Controller for Inverted Pendulum System (진화형 신경회로망에 의한 도립진자 제어시스템의 구현)

  • Shim, Young-Jin;Kim, Min-Sung;Park, Doo-Hwan;Choi, Woo-Jin;Ha, Hong-Gon;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3013-3015
    • /
    • 2000
  • The stabilization control of Inverted Pendulum(IP) system is difficult because of its nonlinearity and structural unstability. Futhermore, a series of conventional techniques such as the pole placement and the optimal control based on the local linearizations have narrow stabilizable regions, At the same time, the fine tunings of their gain parameters are also troublesome, Thus, in this paper, an Evolving Neural Network ControlleY(ENNC) which its structure and its connection weights are optimized simultaneously by Real Variable Elitist Genetic Algorithm (RVEGA) was presented for stabilization of an IP system with nonlinearity, This proposed ENNC was described by a simple genetic chromosome. Through the simulation and experimental results, we showed that the finally acquired optimal ENNC was very useful in the stabilization control of IP system.

  • PDF

The Design, Manufacture and Characteristic Experiment of a Small-Scaled High-Tc Superconducting Synchronous Motor (소용량 고온초전도 동기모터의 제작 및 특성 실험에 관한 연구)

  • Soug, Myung-Kon;Yoon, Yong-Soo;Hong, Gye-Won;Jang, In-Bae;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.241-243
    • /
    • 1999
  • This paper describes a series of experiments investigating the operational characteristics of high-Tc superconducting synchronous motor of five to six hundred watts capacity. In this experiment, ac 220V stator phase voltage and DC 4A excitation current are used, and the synchronous speed runs at 1800rpm. Hall Sensors are installed on the pole face and at the side of the Ag/Bi-2223 high-Tc superconducting tape in order to analyze the effect of the time-varying magnetic field on the motor performance when the load changes its value. The experimental observations are compared with the theoretical predictions.

  • PDF

Comparison of High-Speed Slotless Brushless Machines with Permanent Magnet Array Rotor (회전자의 영구자석 배열에 따른 초고속 슬롯리스 브러시리스 기기의 특성 비교)

  • Jang, Seok-Myeong;Jeong, Sang-Sub;Ryu, Dong-Wan;Cha, Snag-Do;Choi, Sang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.650-652
    • /
    • 2000
  • Proposed slotless PM machine is constructed without stator winding slots. Its stator magnetic material is in the form of a ring and winding have a toroidal configuration and its rotor consists of a 4-pole Halbach array or radially magnetized PM rotor. Thus, airgap flux density distribution and induced emf waveform are essentially sinusoidal. Open circuit magnetic fields and developed torque of each type are presented from the analytical method and finite element method.

  • PDF

Digital PI Control for Constant Speed Driving of Brushless DC Motor (브러시리스 직류전동기의 정속도 운전을 위한 디지털 PI제어)

  • Kim, Hyun-Soo;Baek, Soo-Hyun;Kim, Yong;Maeng, In-Jae;Kim, I1-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.379-381
    • /
    • 1999
  • This paper presents a study of the performance of a brushless DC motor (BLDCM) speed control system. Recently, most motor controls are implemented in digital electronics. Digital controllers tend to be more accurate, less susceptible to noise and more flexible in terms of programming. The system used a digital PI controller in order to implement the constant speed of Brushless DC motor. Microprocessor used in this experiment is 80c196kc. The applied motor has been constructed using a 50W, 150V, 3000rpm, four-pole motor.

  • PDF

Conceptual Design of 100 MW Turbogenerator (가스터빈 구동 공냉식 100 MW 발전기의 개념설계)

  • Park, Doh-Young;Hwang, Don-Ha;Ha, Kyung-Duck;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.88-90
    • /
    • 1998
  • The conceptual design of turbine-driven air-cooled 100 MW generator is presented. The generators rating is 100 MW 3-phase 2pole 13.8 kV 0.85 pf 60 Hz. The conceptual design is described by the process of designing the stator, rotor, and obtaining some of equivalent circuit parameters. The design process starts from the output coefficient G, and utilizes the classical design equations with parameters used in the modern designs. The slot dimensions of the stator and rotor are obtained with their respective winding dimensions.

  • PDF

The Characteristics for the Electrostatically Actuated z-Shaped Laterally Driven MEMS Switch (정전 구동 수평 거동 z-형 MEMS 스위치의 특성)

  • Hong, Young-Tack;Oh, Jae-Geun;Choi, Bum-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2233-2235
    • /
    • 2000
  • We present the characteristics of microwave and mechanical behavior for the electrostatically actuated z-shaped laterally driven micriomachined CPW SPST(Single Pole Single Throw) Switch, which is for the application of the microwave communication systems. In this paper, we have aimed to maintain advantages. such as low insertion loss and low power consumption that the previously developed RF MEMS Switch has and minimize also stiction problem. enhance the microwave characteristics by etching of substrate beneath the switch, realize the pull-in voltage of below 30V. The optimized design parameters of the MEMS Switch can be selected by the analysis of the mechanical behavior and the use of ANSYS simulation method.

  • PDF

Performance Analysis of ARCP Inverter for Power System Interconnection (ARCP(Auxiliary Resonant Commutated Pole) 인버터의 특성분석)

  • Ha, Yo-Chul;Park, Sang-Ho;Kim, Hee-Joong;Han, Byung-Moon;Kim, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1065-1067
    • /
    • 2000
  • This paper describes performance analysis of ARCP Inverter, which can offer zero voltage switching at nominal voltage stress. The system consists of a voltage-source inverter with sort-switching module. Each main switch is connected in parallel with resonant capacitor and two auxiliary switches are placed in series with a resonant reactor for soft-switching capability. The described ARCP inverter could be effectively applied for active power filter reactive power compensator, and UPS.

  • PDF

A Research on Organic Electro-luminescence (유기 전기발광 소자에 관한 연구)

  • Lee, Han-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.82-85
    • /
    • 2005
  • Organic EL has been expected to adopt to a new styles of technology that make flat display after Tang & Vanslyke made good electric luminescence device in late 1980s. Their studies based on multi layer structure that consists of emitting layer and carrier transporting layer using proper organic material. In this study, we made multi layer device using $Eu(TTA)_3(phen)$ as a luminescence material by PVD and investigate luminous properties of each device. But oxidization of organic layer by ITO, energy walls in both pole interface, contaminations of ITO surface, importance of protecting membrane, diffusive dimming of light to cathode organic layer, these causes of degradations are common facts of a macromolecule and micromolecule. We think these degradation caused by the impact of heat and electro-chemical factor, bulk effect and interface phenomenon, and raise a question.

  • PDF

An Experimental Study on the Response of Concrete Pole to Impulsive Current (콘크리트전주의 임펄스전류 응답에 대한 실험적 고찰)

  • Park, Sang-Man;Kang, Moon-Ho;Jeong, Yeong-Ho;Ryoo, Hee-Suk;Nam, Kee-Young;Lee, Jae-Duck;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.482-484
    • /
    • 2003
  • 특별고압 가공배전선로는 일반적으로 콘크리트전주를 지지물로 하고 있고, 선로의 상부에는 가공지선을, 하부에는 중성선을 설치하되, 매전주에서 가공지선, 중성선, 완철을 서로 접속하고 적절한 경간마다 전주에서 접지하도록 하고 있다. 또한 콘크리트전주는 기계적 강도의 유지를 위하여 철근이나 강선을 주골재로 사용하면서도 설계기준에서는 콘크리트전주의 뇌격에 대한 접지효과를 고려하지 않고 있는데, 실험에 의해, 접지선에 어느 정도 이상의 임펄스전류가 흐르면 전주의 철근이 접지회로의 일부를 구성하는 것으로 확인되었다. 본 논문에서는 콘크리트전주의 뇌임펄스에 대한 응답을 실험적으로 고찰하였다.

  • PDF

Minimization of Cogging Force in a Stationary Discontinuous Armature Linear Permanent Magnet Motor at the Outlet Edge

  • Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.288-293
    • /
    • 2011
  • Generally, the discontinuous armature permanent magnet linear synchronous motor (PM-LSM) is composed by the stator block (accelerator, re-accelerator, and decelerator) and the free running section. However, the stationary discontinuous armature design involves the velocity variation of the mover during drive when the armature's non-installation part changes over to installation part as a result of the outlet edge of the armature. Therefore, we considered deforming the shape of the outlet edge at the armature and apply skew on the permanent magnet by displacing the two magnet segments of each pole. This paper presents the results of a three-dimensional (3-D) numerical analysis with a finite element method (FEM) of the force exerted by the outlet edge.