• Title/Summary/Keyword: Electrical Pole

Search Result 1,094, Processing Time 0.023 seconds

Design of Multilayer Ceramic Chip Band Pass Filter with an Attenuation Pole (감쇠극을 갖는 적층형 세라믹 칩 필터의 설계)

  • 강종윤;심성훈;최지원;박용욱;이동윤;윤석진;김현재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.740-743
    • /
    • 2003
  • A multi-layer ceramic (MLC) chip type band-pass filter (BPF) is presented. The MLC chip BPF has the benefits of low cost and small size. The BPF consists of coulped stripline resonators and coupling capacitors. The BPF is designed to have an attenuation pole at below the passband for a receiver band of IMT-2000 handset. The computer-aided design technology is applied for analysis of the BPF frequency characteristics. The passband and attenuation pole depend on the coupling between resonators and coupling capacitance. The frequency characterics of the passband and attenuation pole are analyzed with the variation of the coupling between resonators and coupling capacitance. An equivanlent circuit and structure of MLC chip BPF are proposed. The frequency characteristics of the BPF is well acceptable for IMT-2000 application.

Torque Characteristics Analysis of Interior Permanent Magnet Synchronous Motor According to Pole Arc Ratio (극호비 변화에 따른 영구자석 매입형 동기전동기의 토크 특성 해석)

  • LEE Kab-Jae;Kim Ki-Chan;Lee Jong-In;Kwon Joong-Lok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • The torque characteristics of permanent magnet(PM) motor is varied according to magnet width. In this paper, the design method of magnet and magnetic circuit is proposed in order to improve the torque of Interior Permanent Magnet Synchronous Motor(IPMSM). This paper presents the effects of pole arc ratio and salient pole ratio on the torque and torque ripple in the IPMSM with concentrated winding.

Neutral Current Calculation of Pole-Top Overhead Distribution Line (가공 배전선로 장주의 중성선 전류 계산)

  • Seo, Hun-Chul;Kwon, O-Sang;Kim, Chul-Hwan;Jung, Chang-Soo;Yoo, Yeon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.290-296
    • /
    • 2006
  • If the three phases are not balanced, the current in neutral wire is not zero. Then, the induced voltage can be generated in communication line. The KEPCO's rule about unbalanced current for one step type in distribution pole is a twenty percent of phase current. But the unbalanced current for two step type in distribution pole can't decide the rule because there are many different views. This paper presents the calculation and analysis technique of neutral current in distribution poles using equivalent circuit analysis and EMTP simulation.

The Deterioration Diagnosis of pole Transformer using Remote Measurement (주상변압기의 열화진단을 위한 원격측정)

  • 송현선;이상돈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • This paper proposes on-line based a deterioration diagnosis pole transformers using various sensors such as thermistor, current transformer and potential transformer. We measured load current and temperature to diagnose pole transformer using R/F( radio frequency ) wireless data communication module. We represent the graphs of their feature. The result of this paper shows that the proposed device car be used as deterioration diagnosis device of pole transformers.

Robust Pole Assignment of Linear Systems with Time-Varying Uncertainty (시변 불확정성을 갖는 선형 시스템의 강인 극점 배치)

  • Kim, Jin-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.31-35
    • /
    • 1999
  • In this paper, we consider the robust pole assignment and the upper bound of quadratic cost function for the linear systems with time-varying uncertainy. The considered uncertainties are both the norm bounded unstructured case and the structured case that has the matrix polytope type uncertain structure. We derve conditions that guarantee the robust pole assignment inside a disk in the L.H.P. and the robust stability. Also, we derive the upper bound of quadratic cost for thil pole assigned systems. Finally, we show the usefulness of our results by an example.

  • PDF

Dynamic PCA algorithm for Detecting Types of Electric Poles (전신주의 종류 판별을 위한 동적 PCA 알고리즘)

  • Choi, Jae-Young;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.651-656
    • /
    • 2010
  • This paper proposes a new dynamic PCA algorithm to recognize types of electric poles, which is necessary for a mobile robot moving along the neutral line for inspecting high-voltage facilities. Since the mobile robot needs to pass over the electric poles and grasp the neutral wire again for the next region inspection, the detection of the electric pole type is a critical factor for the successful passing-over the electric pole. The CCD camera installed on the mobile robot captures the image of the electric pole while it is approaching to the electric pole. Applying the dynamic PCA algorithm to the CCD image, the electric pole type has been classified to provide the stable grasping operation for the mobile robot. The new dynamic PCA algorithm replaces the reference image in real time to improve the robustness of the PCA algorithm, adjusts the brightness to get the clear images, and applies the Laplacian edge detection algorithm to increase the recognition rate of electric pole type. Through the real experiments, the effectiveness of this proposed dynamic PCA algorithm method using Laplacian edge detecting method has been demonstrated, which improves the recognition rate about 20% comparing to the conventional PCA algorithm.

Mathematical Analysis and Simulation Based Survey on Initial Pole Position Estimation of Surface Permanent Magnet Synchronous Motor

  • Kim, Tae-Woong;Wheeler, Patrick;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.499-506
    • /
    • 2009
  • In this paper, the initial pole-position estimation of a surface (non-salient) permanent magnet synchronous motor is mathematically analyzed and surveyed on the basis of simulation analysis, and developed for accurate servo motor drive. This algorithm is well carried out under the full closed-loop position control without any pole sensors and is completely insensitive to any motor parameters. This estimation is based on the principle that the initial pole-position is simply calculated by the reverse trigonometric function using the two feedback currents in the full closed-loop position control. The proposed algorithm consists of the predefined reference position profile, the information of feedback currents, speed, and relative position, and the reverse trigonometric function for the initial-pole position estimation. Comparing with the existing researches, the mathematical analysis is introduced to get a more accurate initial pole-position of the surface permanent magnet motor under the closed-loop position control. It is found that the proposed algorithm can be easily applied in servo drive applications because it satisfies the following user's specifications; accuracy and moving distance.

Construction and Characteristics of Single Phase Switched Reluctance Motor

  • Oh, Young-Woong;Lee, Eun-Woong;Lee, Jong-Han;Kim, Jun-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.1
    • /
    • pp.6-11
    • /
    • 2004
  • The single phase switched reluctance motor (SRM) has many merits; simple structure and driving circuits, easy operation and speed control, and etc. This paper presents the torque characteristics of disk type single phase SRM by changing the salient pole lengths and pole arcs. The prototype single phase SRM has a three dimensional magnetic flux pattern because of its structure. That is, the radial and axial magnetic flux contributes to torque generation. Thus, 3D analysis is required for computation of its magnetic field. In this paper, 3D FEM is used for analyzing the magnetic flux distribution and magnetic co-energy.

Research on Dielectric Characteristics of Environmental-Friendly Vegetable Insulation Oil for the Pole Transformer (주상변압기 적용을 위한 친환경 식물성절연유의 절연특성 연구)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.81-85
    • /
    • 2010
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The vegetable insulation oils are highly biodegradable, have negligible effect on the environment, human health and ecosystem. Therefore, to assure their safe use in electrical power systems, it may require some processing and modification to improve some of their physical, chemical, thermal and electrical properties. This paper provides a comparative results of the electrical breakdown properties of several vegetable insulation oils and mineral oil to use as dielectric fluid in environmental-friendly pole transformer. Also, the electrical breakdown property of the Nomex and kraft insulation papers in vegetable insulation oil is examined.

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF