• 제목/요약/키워드: Electrical Performance

검색결과 15,407건 처리시간 0.043초

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

Design Characteristics on Electric Drivetrain for Electric Vehicle Based on Driving Performance

  • Park, Ji-Seong;Jung, Sang-Yong
    • 전기전자학회논문지
    • /
    • 제13권3호
    • /
    • pp.47-54
    • /
    • 2009
  • Design consideration on electric drivetrain(E-D/T), usually referred as electric motor for driving, its compatible reduction gear, and inverter, are performed for developing electric vehicle(EV) with efficient driving performance. Universal mode of driving cycle has been used to make up the actual vehicle performance, and its results are incorporated to the design of E-D/T.

  • PDF

외란 관측기를 이용한 동적 시스템의 성능 개선 (Performance Enhancement of Dynamic Systems by Disturbance Observers)

  • 오경환;정정주;백문철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.241-244
    • /
    • 2002
  • Using disturbance observers is effective in enhancing the performance of systems in presence of disturbances. In this paper, we present a novel design of disturbance observers to achieve enhanced robust performance. In addition, we propose a new method of reducing the effect of measurement noise via modification of plant modeling in disturbance observer.

  • PDF

Modeling Strategies of Cheju-Haenam HVDC System and Its Dyanmec Performance Study

  • Jung, Gil-Jo;Kim, Chan-Ki;Yang, Byeong-Mo;Kwak, Hee-Ro
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권2호
    • /
    • pp.40-50
    • /
    • 2001
  • This paper deals with the development of the simulation models Cheju - Haenam HVDC system and its dynamic performance study and verify the control characteristics of the HVDC system. It discusses the model development requirement and criteria. It provides guedelines for developing large-scale simulation models for detailed electromagnetic studies and presents the results of the modeling project.

Optimizing Instruction Prefetching to Improve Worst-Case Performance for Real-Time Applications

  • Ding, Yiqiang;Yan, Jun;Zhang, Wei
    • Journal of Computing Science and Engineering
    • /
    • 제3권1호
    • /
    • pp.59-71
    • /
    • 2009
  • While the average-case performance is important for general-purpose applications, worst-case performance is crucial for real-time systems to ensure schedulability and reliability. Recent work has shown that simple prefetching techniques such as the Next-N-Line prefetching can benefit both average-case and worst-case performance; however, the improvement on the worstcase execution time (WCET) is rather limited and inefficient. This paper presents two instruction prefetching approaches that are specially designed to enhance the worst-case performance, including the loop-based prefetching and WCET-oriented prefetching. Our experiments indicate that both instruction prefetching techniques can achieve better worst-case execution cycles than the Next-N-Line prefetching while having various impacts on the average-case performance.

A Study on how chromatic adaption affects human visual performance of display

  • Lee, Hwal-Ly;Woo, Jong-Seok;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1550-1553
    • /
    • 2009
  • We studied the human visual performance with PDP and LCD to clarify the relationships between viewer preference and chromatic adaption. In this paper, optical performance of the display is measured mechanically based on standard. The human visual performance about the display color image quality trough optical process is represented numerically based on CIECAM02. By comparing these results with the result of the questionnaire, performance of the display can be evaluated in detail.

  • PDF

Performance Analysis for Secured Service Signals of RNSS Systems

  • Han, Kahee;Lee, Subin;Lee, Kihoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.341-349
    • /
    • 2022
  • When designing a new RNSS signal, the performance analysis for the legacy signal providing the same service, is required to determine the performance requirements. However, there are few studies on the secured service (SS) signal performance analysis, and the waveform is the only published information on the signal design component of the SS signal. Therefore, in this paper, we introduce several figures-of-merit (FoMs) that can be used for performance analysis in terms of the waveform. And then, we calculate the FoMs, such as autocorrelation main peak to secondary peak ratio (AMSR), spectral efficiency, Gabor bandwidth, multipath error, and jamming resistance quality factor, for the existing SS signals and discuss the analysis results. Finally, we conclude that the superior waveform for each FoM is different, and that the consideration of the trade-off relationship between the FoMs is required for waveform design.

태양광 발전의 성능향상을 위한 PV/T 시스템 개발 (Development of PV/T for Performance Improvement of Photovoltaic System)

  • 최정식;고재섭;강성준;백정우;장미금;문주희;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.95-96
    • /
    • 2010
  • This paper proposes photovoltaic thermal hybrid module to get the electrical and Thermal performance of building integrated photovoltaic(BIPV) system. BIPV system is decreased the system efficiency because output of PV is decreased by the thermal rising on generating. In order to improve the efficiency of BIPV module, water cooling system is applied and generated thermal is used the warm water system. Water cooling system uses the flux control algorithm considering water temperature and power loss. Electrical and thermal performance of proposed photovoltaic thermal hybrid module is confirmed through the actual experiment and herby proved the valid of this paper.

  • PDF

비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구 (A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology)

  • 이기연;문현욱;김동우;임용배;최동환;김용혁
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.