• Title/Summary/Keyword: Electrical Performance

Search Result 15,407, Processing Time 0.038 seconds

Electrical Properties of Silicone Rubber Filled with Surface Treated Alumina Trihydrate

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.134-140
    • /
    • 2006
  • The effect of surface treatment of fillers on the mechanical, electrical properties, and tracking performance of silicone rubber insulators have been investigated. For base polymer, $\alpha,\;\omega$) vinyl poly(dimethyl-methylphenyl) siloxane(VPMPS) containing dimethyl siloxane and methylphenyl siloxane was prepared by the equilibrium polymerization. High voltage silicone rubber composites(HVSRC) were prepared from VPMPS, nano-silica, and alumina trihydrate (ATH) modified by various coupling agents. Bound rubber of uncured silicone rubber, cross-linking density of the vulcanizate as well as the mechanical, electrical properties, and tracking performance were measured.

A design Scheme of Fuzzy Sliding Mode Controllers for Improving Performance (슬라이딩 모드 제어기의 성능 개선을 위한 제어기 설계 기법)

  • 강종하;권순학;이석규;이달해;박찬규
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.150-155
    • /
    • 1998
  • Sliding mode control is a powerful control methodology for the control of uncertain systems. However, it and its variations have some disadvantages such as chattering and imprecise tracing performance. A novel scheme of the sliding mode control is presented for the accurate tracking control of the uncertain systems. The fuzzy logic-baced control law maintaining stability and consistent performance in the face of modeling imprecise is derived and simulation results showing its effectiveness are presented.

  • PDF

The Design of Extended Robust $H_{\infty}$ Filter for Glint Noise (글린트 잡음에 대한 확장 강인 $H_{\infty}$ 필터 설계)

  • Kwak, Ki-Seok;Shin, Jong-Gu;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.1961-1963
    • /
    • 2001
  • In a target tracking problem, the radar glint noise has non-Gaussian heavy-tailed distribution and will seriously affect the target tracking performance. In this study, an extended robust $H_{\infty}$ was developed which can significantly improve the tracking performance when glint noise is present. Through the computer simulations, the proposed filter showed superior and robust tracking performance compared with other extended Kalman filters.

  • PDF

Low-Speed Performance Improvement of Slip Based Sensorless Control for Three-Phase Induction Motor Used in Treadmill (트레드밀에 사용되는 3상 유도전동기의 슬립 기반 센서리스 제어 저속성능 향상)

  • Lee, Su-Hyoung;Lee, Sang-Hee;Mun, Tae-Yang;Han, Hee-Min;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Recent high-end treadmills are demanding stable performance at lower speeds. In this study, a slip control-based induction motor sensorless algorithm for treadmills, which have heavy load variations, is proposed. A modified Gopinath flux estimator is used to evaluate the rotor flux. Results indicate that a good speed regulation performance is achieved even at a low speed of approximately 3 Hz with a nominal exercise load of 90 kg body weight. The slip calculation method in the stationary coordinate system is adopted to improve the control stability. The proposed algorithm is verified throughout the simulation study using PSIM, and the experimental test consists of a commercial treadmill system.

The Development of Neuromuscular Electrical Stimulation Medical Devices for The Treatment of Non-implantable Urinary Incontinence (비이식형 요실금 치료용 신경근 전기자극 의료기기 개발)

  • Lee, Jae-Yong;Lee, Chang-Doo;Kwon, Ki-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, the neuromuscular electrical stimulation medical devices for non-implantable incontinence treatment other than vaginal insertion type was developed and commercialized. The structure of medical devices for electrical stimulation based on the anatomy of the pelvic floor muscle designed. Then, the optimum parameters that may be effective in pelvic floor muscle electrical stimulation was set. The circuit system based on the optimum parameters were designed and manufactured. The frequency of the pulse voltage for electrical stimulation is 75[Hz], the pulse width is 300[${\mu}s$], the development of medical devices was to have seven program functions to the various treatments. The circuit system of medical devices was composed of microcontroller, comparator and converter. The performance of the developed circuit system in KTC(Korea Testing Certification) were carried out medical equipment inspection test. Test results, test specifications were satisfied with the medical device, the performance was verified to be commercialized as a medical device. The development of medical devices were validated risk assessment and product performance through a software validation. Commercialization of medical equipment was acquired to enable the certification standards of the international standard IEC 60601-1.

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Energy Balance Analysis and Operation of Electrical Power System in KOMPSAT-1 (다목적실용위성 1호기의 에너지 밸런스 및 운용)

  • Jang, Sung-Sao;Lee, Sang-Kon;Jang, Jin-Baek;Sim, Eun-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1040-1042
    • /
    • 2002
  • In general, satellite electrical power system plays an important role in its mission performance. To perform the mission successfully, the satellite should be provided with the sufficient power until end of life. In this paper shows that electrical boxes' design characteristic, energy balance analysis and power performance in satellite real operation.

  • PDF

Silicon Thin-Film Transistors on Flexible Polymer Foil Substrates

  • Cheng, I-Chun;Chen, Jian Z.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1455-1458
    • /
    • 2008
  • Amorphous silicon (a-Si:H) thin-film transistors (TFTs) are fabricated on flexible organic polymer foil substrates. As-fabricated performance, electrical bias-stability at elevated temperatures, electrical response under mechanical flexing, and prolonged mechanical stability of the TFTs are studied. TFTs made on plastic at ultra low process temperatures of $150^{\circ}C$ show initial electrical performance like TFTs made on glass but large gate-bias stress instability. An abnormal saturation of the instability against operation temperature is observed.

  • PDF

Extending the SRIV Identification Algorithm to MIMO LMFD Models

  • Akroum, Mohamed;Hariche, Kamel
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.135-142
    • /
    • 2009
  • In this paper the Simplified Refined Instrumental Variable (SRIV) identification algorithm for SISO systems is extended to MIMO systems described by a Left Matrix Fraction Description (LMFD). The performance of the extended algorithm is compared to the well-known MIMO four-step instrumental variable (IV4) algorithm. Monte Carlo simulations for different signal to noise ratios are conducted to assess the performance of the algorithm. Moreover, the algorithm is applied to a simulated quadruple tank process.