• Title/Summary/Keyword: Electrical Equipments

Search Result 862, Processing Time 0.023 seconds

A Study on the Data Aquisition System for Power Quality Analysis of Load Equipment (부하설비의 전력품질 분석을 위한 데이터 획득시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.92-94
    • /
    • 2007
  • In order to analyze voltage, current, electrical power, harmonics and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible. Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load. So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

  • PDF

Comparison with Ultra-Violet and Ultra-Sonic Generated by an Insulator at 22.9kV (22.9kV 애자에서 발생한 자외선과 초음파의 비교)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Young-Seog;Jung, Jin-Soo;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.182-183
    • /
    • 2007
  • Recently, diverse techniques for diagnosis on power equipments of the live wire conditions are developed. These techniques are very important that find out the fault signs in power equipments. This paper is Compared with Ultra-Violet and Ultra-Sonic Generated by an Insulator at 22.9kV. The volume of UV images are increased by the square of the applied voltage. The output signals of ultrasonic are detected at about 20kV to 30kV. Hereafter, through the continuous DAQ and analysis, these techniques are the effective method for the improvement of the exciting diagnosis.

  • PDF

Transport Capacity Design and Characteristics Evaluation of Al/Cu Composite Busbar for Power Equipments (전력기기용 Al/Cu 복합 부스바의 통전용량 설계 및 특성 평가)

  • Bae, Joon-Han;Kim, Hae-Joon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.628-632
    • /
    • 2006
  • This paper deals with the electric and thermal characteristics of the composite busbar composed of aluminum and copper. When AC current is flowing in Cu busbar used widely in conservative equipments like power cable, transformer, and switchgear & controlgear most current is concentrated on the surface of the busbar by the skin effect. Therefore, if the Cu region in the busbar having low current density is replaced with aluminum, we can largely reduce the product cost and weight of the busbar. To conform the performance of the composite busbar, we designed and fabricated a test Al/Cu composite busbar. Maximun temperature rise of the busbar was $35^{\circ}C$ when 1600 Arms of AC current was applied to the test composite busbar($120mm{\times}10mm$). Based on test results, we can expect to make the low-priced and light power equipments using the Al/Cu composite busbar.

Design of Characteristics Test Equipment for a Large Capacity Thyristor (대용량 사이리스터 특성평가 장비의 설계 및 제작)

  • Seo Kil-Soo;Kim Hyoung-Woo;Kim Ki-Hyun;Kim Nam-Kun;Kim Eun-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.567-572
    • /
    • 2005
  • Recently, application area of the thyristor is extends to power conversion systems, such as HVDC, BTB, SVC and FACTS. Therefore, reliability diagnostic technique on thyristor is needed to obtain stability and maintenance of power conversion systems. To measure the characteristics of the thyristor, test equipments which based on IEC 747-6 and KS C 7023 standard are needed. In this paper, we presents the design and manufacture of the test equipments for 6.5kV/4.2kA thyristor which used in thyristor valve of HVDC conversion systems by using test standard. Voltage, current, dv/dt and turn-off time test equipments were designed and manufactured. Each systems were made separately, but unity operation can possible.

Analysis of Oscillation Modes Occurred by ON/OFF Time Intervals of Switching Equipments by the RCf Method (RCF 해석법을 사용한 스위칭 설비의 ON/OFF 시간간격에 의한 진동모드 해석)

  • Kim, Deok-Young;Dong, Moo-Hwan;Lee, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.13-17
    • /
    • 2006
  • In this paper, the RCF(Resistive Companion Form) analysis method which is used to analyze small signal stability problems of non-continuous systems including switching devices. The RCF analysis method is mathematically rigorous and computes eigenvalue of the system periodic transition matrix based on discrete system analysis method. As an effect of switching operations, the eigenvalues of the systems are changed and newly unstable oscillation modes may be occurred. As an illustrating example, the oscillation modes of the system with different switching time intervals are computed exactly by the RCF analysis method and the results show that ON/OFF time intervals of switching equipments are important factors to make the system stable or unstable. This result shows that the RCF analysis method is very powerful to analyze small signal stability problems of power systems including switching devices such as FACTS equipments.

A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag (순간전압강하에 대한 비선형 저압전기기기의 동적특성)

  • Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

Analysis of Vehicle Fire Accident Caused by Defect of Optionally Established Equipment (부가적으로 설치된 장치 결함으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.40-46
    • /
    • 2014
  • This paper deal with due to the additional equipment established on the vehicle fire accident cases. Recently, vehicle was recognized as other living spaces and it was increasing installation of additional devices such as a black box, multivision, additional battery and so on. However, these additional devices were established on the vehicle by non-specialists such as the general public user or manufacturing and distributors of additional devices since the vehicle factory. Resulting from the additional equipments due to installation errors in these additional equipments connected to the electrical wiring insulation damage or electrical breakdown occurs, and finally leading to a fire caused by the additional equipments. Therefore, additional equipment established on the vehicle due to a fire in order to prevent accidents during the manufacturing process of these devices are installed. If not installed unless the manufacturing process, the installation of additional equipments established by professional who knows the vehicle structure that will be able to prevent the fire.

Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment (전기통신설비를 위한 옥내외 겸용 면진테이블 설계)

  • Lee, Chun-Se;Ahn, Hyeong-Joon;Lee, Taek-Won;Son, In-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF

카본파이버 매트 전극접지 기술

  • Choe, Un-Gu;Eom, Ju-Hong;Kim, Gwang-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.32-40
    • /
    • 2008
  • Recently, due to the onset of the information age, various high-priced, large-size machines have been invented such as intelligent building and high-tech computer operated facilities. Consequently, all kinds of electrical, electronic, and communication equipments and facilities have been found to be vulnerable even to small amounts of electrical shock. Interference between equipments and equipment malfunction occur because of various electromagnetic interferences. Galvanic action by direct current (D.C.) causes gas valve corrosion and other electrical problems such as static electricity and electromagnetic interference (EMI) occur as well. Most of the problems stated above occur because of problems in grounding.

  • PDF