• Title/Summary/Keyword: Electrical Equipments

Search Result 862, Processing Time 0.029 seconds

Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function (데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Seok-Myung;Joo, Nam-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.

A Study on the Motor Overload Interrupt system (전동기 과부하 차단 시스템에 대한 연구)

  • Choi Jang Gyun;Yoon Suk Am;Gang Byeong Bog;Lee Jeong Il;Cho Kyeng Jai;Cha In Su
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.73-76
    • /
    • 2002
  • In electrical machinery and apparatus, the most important problem is protect of machinery and apparatus in due to transient phenomena and overload on operation. Particularly by advanced technology of late, there Is demand for low cost of equipments and high percentage of use of equipments. Therefore, protection of machinery and apparatus In condition of overload is more valued considering that all efficiency increase is passed by operating all machinery and apparatus in condition of heavyload. In this paper, the suggested system is added overload interrupt system using CT in condition of overload.

  • PDF

A Study on the motor's overload protect system applying PIC (PIC를 적용한 Motor 과부하 방지 시스템에 대한 연구)

  • Kang, Byung-Bog;Yoon, Su-Am;Lim, Jung-Yeol;Yoon, Jung-Phil;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.28-30
    • /
    • 2002
  • In electrical machinery and apparatus, the most important problem is protect of machinery and apparatus in duo to transient phenomena and overload on operation. Particularly by advanced technology of late, there is demand for low cost of equipments and high percentage of use of equipments. Therefore, protection of machinery and apparatus in condition of overload is more valued considering that all efficiency increase is passed by operating all machinery and apparatus in condition of heavyload. In this paper, the suggested system is add overload protect system using CT in condition of overload.

  • PDF

An Implementation for Effective Shielding System of Information Electronic Equipments (정보가전기기의 효과적인 차폐시스템 구현)

  • Kim, Jae-Yee;Jeong, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2031-2033
    • /
    • 2004
  • In this paper, electromagnetic wave environment generated from electronic equipments was investigated. Since the main source of electromagnetic waves are electronic equipments, the field intensity of a harmful electromagnetic wave was measured and its harmful level was analyzed. It was also found that the result was 23%${\sim}$38% in case of TV set and microwave oven. Based on this analysis, this study proposed efficient shielding method to suppress unwanted electromagnetic wave.

  • PDF

A plan to harmonize the equipments of power distribution with its environment (배전설비의 환경조화방안)

  • Lee, Jae-Gwan;Kim, Sang-Yul
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1206-1209
    • /
    • 1998
  • For 21th Century, the assignment of power distribution will be the expansion of equipments to supply electric power and harmony with its environment, in process of approving value consciousness of land, space, and the preservation of surroundings. This paper proposes a plan to match with the requirement about equipments, having ability to supply electric power, being harmonized itself with its surroundings by applying a general concept of "Amenity" when we choose an established form of power distribution.

  • PDF

Short-term Operation Strategy of Cogeneration System with Auxiliary Equipments (다양한 보조설비를 가진 열병합발전시스템의 단기운전계획)

  • Lee, Jong-Bum;Jung, Chang-Ho;Lyu, Seung-heon
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.24-26
    • /
    • 1994
  • This paper describes a numerical model for the short-term operation strategy of the cogeneration systems. Especially this paper considered various auxiliary equipments used for the effective operation of cogeneration system. Minimum daily operation costs of topping cycle are calculated by using LP. Simulation results of some cases are analyzed and compared each other. Through these simulations the validity of the proposed model considered various auxiliary equipments is verified.

  • PDF

A Study on the Actual Condition Investigation of the Disconnecting Switchgear of 170kV GIS (170kV GIS용 단로기의 현장 사용 실태 조사)

  • Lee, Eun-Suk;Kim, Jong-Seo;Cheon, Jong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1180-1183
    • /
    • 2003
  • 170kV GIS(Gas Insulated Switchgear) is widely used in large industrial factory-electrical facilities of private use because has many benefits. But Other equipments's failures are occurred by GIS failures and give rise economic problems to user. Therefore we will examine the actual condition of the 170kV GIS-electrical facilities of private use and are able to confirm the distribution characteristic analysis of disconnecting switchgear. In this paper, we presents the actual condition investigation of the disconnecting switchgear of 170kV GIS-electrical facilities of private use by post - failure pattern, inspection method, test equipments and so forth.

  • PDF

Analysis of Harmonic Frequency for Return Current on the Track Circuit in Electrical Railway System (전기철도시스템에서 궤도회로 측면의 귀선전류 고조파 분석)

  • Beak, Jong-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.698-704
    • /
    • 2012
  • Electric power used in electrical vehicles flows into the substation through the feedback circuit, track circuit. Due to these power conversion equipments in electrical railroads, return current contains harmonics, and it should not affect other communication lines. In this paper, based on the return currents, we measured harmonics and analyzed an influence in railway equipments due to the harmonics. For analysis, we utilize the measured values of return currents measured in track circuits, and predictive values of those compared to the earth methods between the existing electrified sections. Applying the regulations used for Gyeongbu HSL(High Speed Line), the results of measured harmonics have found to be acceptable.