• Title/Summary/Keyword: Electrical Equipments

Search Result 862, Processing Time 0.029 seconds

A method to reject noise signals in partial discharge signals of turbine generator (터빈 발전기의 부분방전 신호 중 노이즈 제거 방법)

  • Park, Y.H.;Park, P.G.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.240-242
    • /
    • 2005
  • It is well known that the PD (Partial Discharge) signals are generated if insulators have some defects such as voids in electrical facility and various PD detection methods are developed for preventing electrical troubles. So, an interest for the PD signals is higher and higher according to the high concern for the defects detection method of the aging electrical facility. When the equipment to detect PD signals installed at site and it works, a lot of noises flow in the equipment from surrounding situation and it will be mixed with original PD waveform. So we can not get the desired PD waveform. Therefore, there are many trial to reject or suppress the noise from the PD signals from long times ago. The greater of them used the hardware such as bridge circuits and frequency filters to suppress the noise. This paper proposed a novel noise rejection method in acquired data from PD detection equipment. The noise has the irregular phase and higher signal level than real PD, and noise decision is performed after inspection of pulse distribution in ${\Phi}$-q-n graph of acquired data from PD detection equipments. By experimental results on high voltage electric equipments, it is shown that proposed method has good performance. It is expected that this noise rejection technology is useful in numeric calculation and trend management of PD level.

  • PDF

The Countermeasure about Harmonics of the High Voltage Power Facilities (고압수전설비의 고조파에 관한 대책)

  • Kim, Ju-Chan;Sin, Su-Han;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.353-357
    • /
    • 2004
  • This paper presents the result of survey of case study for harmonics in electrical installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. To suppress harmonics in electrical ins tallations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

DIAGNOSIS OF DETERIORATION FOR HIGH VOLTAGE CABLE (전력 케이블의 열화진단)

  • Choi, Chang-Su;Kim, Young;Kim, Jang-Woen;Kim, Young-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1353-1355
    • /
    • 1995
  • While the modern society has been highly diversified and civilized, the demand for the safty of a power transmission has been greatly increased. For the underground cable, the performance of the electrical equipments is being improved by developing a new technology, and the reliability of the power supply is being up graded by impressing the diagnostic and monitoring technology of the system. In this paper the aging procedure of O.F and XLPE cables are described, including the diagnostic and monitoring equipments and the future subject.

  • PDF

A Study on Tracking Control for Networked Multi-Motor Systems

  • Lee, Hong-Hee;Jung, Eui-Heon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1897-1900
    • /
    • 2004
  • In recent years, a lot of industrial equipments have serial communication channel such as FieldBus (CAN, Profibus, etc.) or Ethernet that provides real time communication between industrial equipments. Theses applications include gantry crane, robot, chip mounter, etc.. In this paper, we discuss the synchronization technique for networked multi-motor systems where controllers (commercial servo amps) are distributed and interconnected by CAN (Controller Area Networks). We first describe the equivalent model for the individual servo-amp and motor using the frequency response. We design the $H{\infty}$ controller for motion synchronization. Finally, the synchronization technique using the equivalent model and the $H{\infty}$ controller is verified by the simulation and the experiment.

  • PDF

Sensitivity Analysis of Power System Oscillation Modes Induced by Periodic Switching Operations of SVC by the RCF Method (RCF 기법을 이용한 SVC의 주기적 스위칭 동작에 의한 전력계통 진동모드 감도해석)

  • Kim, Deok-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.363-368
    • /
    • 2008
  • In this paper, the Resistive Companion Form(RCF) analysis method is applied to analyze small signal stability of power systems including thyristor controlled FACTS equipments such as SVC. The eigenvalue sensitivity analysis algorithm in discrete systems based on the RCF analysis method is presented and applied to the power system including SVC. As a result of simulation, the RCF analysis method is proved very effective to precisely calculate the variations of eigenvalues or newly generated unstable oscillation modes after periodic switching operations of SVC. Also the eigenvalue sensitivity analysis method based on the RCF analysis method enabled to precisely calculate eigenvalue sensitivity coefficients of controller parameters about the dominant oscillation mode after periodic switching operations in discrete systems. These simulation results are different from those of the conventional continuous system analysis method such as the state space equation and proved that the RCF analysis method is very effective to analyze the discrete power systems including periodically operated switching equipments such as SVC.

Risk Analysis Method Applied to Train Control Systems for Safety Assurance (열차제어시스템 안전성 확보를 위한 위험도 분석 방법 적용)

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.5
    • /
    • pp.71-76
    • /
    • 2007
  • Failures of equipments for train control systems are linked directly to extensive damages of human lives or financial losses from the increasing uses of train control equipments utilizing computers. Then safety activities for assuring safety and reliability are needed during the system life-cycle. Risk analysis is important phase to increase safety from determining the risk presented by the identified hazard. In this paper, we investigated several methods for risk estimation of safety activities, and then we drew a comparison between original methods to suggest optimized one in the application to train control systems. In the result of the comparison, we had plan to propose the risk analysis method called Best-Practice(BP) risk method combining advantages of the qualitative and the quantitative analysis. In addition, we attempted to apply the BP-risk method to domestic train control systems handling in Korea.

The Study for Mitigating Voltage Sags in Distribution System (배전계통에서의 전압저하 저감방법에 관한 연구)

  • 오용택;김진성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.139-145
    • /
    • 2002
  • Recently, power-electronics equipments or machine that microprocessor is included and computers have been installed continuously in industrial process or region of electronics customer. So concern for power quality, especially sags has been increased. Because those equipments are very sensitive to sags. The sag is phenomenon that magnitude of load voltage temporarily decreases because of power system fault. If a certain equipment in industrial process have any trouble result from sag, it can cause utility to be charged for enormous economics loss. Therefore it need to analyze the characteristic of sag and then mitigation method for sags in distribution system in odor to increase reliability. This paper gives an overview of sags characteristic due to short circuit fault in distribution system and after a general discussion of the various forms mitigation, gives a sags mitigation method with concentrating on changing the distribution system like spot network, on-site generation.

  • PDF

A Study for the Shaft Vibration of the Vertical Type Hydro Electric Power Generator (수축형 수차발전기 축진동에 관한 연구(I))

  • 이승원
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.28-37
    • /
    • 1964
  • It is the intention of this thesis to discriminate and investigate the cause of the shaft vibration of the vertical type hydroelectric power generator with respect to electrical, mechanical and hydraulic aspects, and to analyze the vibration which will occure by the each cause investigated above. In order to test the shaft vibration of No.1 generator in Hwachon, Korea new measurement method and measuring equipments were designed. In practice the shaft vibration of the generator was measured by above equipments and analyzed by the discriminative method. Detailed explanation for the designed measurement method and instruments is presented, and the results which I had tested three times for the generator No.1 in Hwachon power plant are added. As a appendix the mechanism and causes of the thrust bearing's wear and remarks for the runner are written.

  • PDF

Results of capacity calculations of the electrical equipments for Tilting EMU(TTX) (전기식 틸팅차량(TTX)의 차량전기시스템 용량산정에 관한 연구)

  • Han, Seong-Ho;Lee, Su-Gil;Han, Yong-Jae;Song, Yong-Su;Lee, Eun-Kyou
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1435-1437
    • /
    • 2004
  • Tilting train has been developed to increase the operational speed of the trains on conventional lines which have many curves. This train are tilted at curves to compensate for unbalanced carbody centrifugal acceleration to a greater extent than compensation produced by the track cant, so that passengers do not feel centrifugal acceleration and thus trains can run at higher speed at curves. This paper show that results of normal capacity calculations of the electrical equipments such as Main transformer, PWM converter, VVVF inverter, traction motor in TTX(tilting train express) with maximum operation speed 180 km/h.

  • PDF