• Title/Summary/Keyword: Electrical Equipment

Search Result 2,796, Processing Time 0.038 seconds

Study on Development of Insulation Degradation Diagnosis System for Electrical System (전기기기 절연열화진단 시스템개발에 관한 고찰)

  • Kim, Yi-Gon;Yoo, Kwen-Jong;Kim, Seo-Young;Cho, Yong-Sub;Bak, Bong-Seo;Choi, Si-Young;Sim, Sang-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.231-235
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D Patterns from analyzing it. For fettering the noise contained in sensor signals we used ICA algorithms. Using this data design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

Quantitative Analysis of Workload for Classifying the Operating Area of Distribution Control Center (배전관제센터의 운전영역 구분을 위한 정량적 업무량 분석)

  • Go, Seok-Il;Seo, Dong-Kwen;Choi, Joon-Ho;Ahn, Seon-Ju;Kim, Hyun-Woo;Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.200-207
    • /
    • 2018
  • In recent, KEPCO (Korea Electric Power Corporation) faced difficulties of the DCC (distribution control center) due to the increase of field equipment and operational cost, and aging of operating staffs. In response to these changes in the DCC, KEPCO is trying to change the organization and system of the DCC. In this paper, we present a new attempt to change organization and structure of distribution control center, which was implemented by KEPCO recently. This paper is divided into three major parts. First, to examine the adequacy of the divided basis of current DCCs based on the quantity of installed electrical equipment, we analyzed the correlation between the operational history of the DCCs and the number of equipment. Through the analysis, we confirmed that there is little relationship between the number of equipment and actual workload. Second, we conducted visits and questionnaire surveys of all the DCCs to identify factors affecting the actual workload of distribution operators and then summarized the results. Third, based on this survey, a general formula for analyzing the workload of a DCC was derived, and each DCC's average annual total workload, day/night workload, and required number of personnel were calculated. Through this study, we proposed a more realistic management method of DCCs that can overcome the division criteria based on equipment quantity.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash (수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰)

  • Lee, Kiyeon;Gil, Hyoungjun;Kim, Dongook;Kim, Dongwoo;Kang, Daechul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

Imperfect Preventive Maintenance Plan of Generation Unit Using Quasi-renewal Theory (Quasi-renewal 이론을 이용한 발전설비의 불완전한 유지보수 예방정비 계획)

  • Kim, Hyung-Jun;Byun, Yoong-Tae;Kim, Jin-O;Lee, Jun-Kyong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.735-740
    • /
    • 2008
  • Recently, the research of PM (Preventive Maintenance) method on the RCM(Reliability-Centered Maintenance) of the system equipment is being actively advanced for a few years. For the most of the current power equipment maintenance, the state of the equipment after maintenance is assumed to be becoming 'as good as new ones' state. However, the state of the power equipment is maintained like the states of the between 'as good as new ones' and 'as bad as old ones' by imperfect maintenance that implies the life decrease of the equipment by frequent breakdown, the error of maintenance process, and so on. So, the Maintenance method considering the real case has to reflect Imperfect maintenance than perfect maintenance. This paper suggests the Preventive Maintenance method by using Quasi - Renewal Theory for the gas turbine equipment as deliberating the imperfect maintenance for the real cases.

Fault Detection for Ceramic Heater in CVD Equipment using Zero-Crossing Rate and Gaussian Mixture Model (영교차율과 가우시안 혼합모델을 이용한 박막증착장비의 세라믹 히터 결함 검출)

  • Ko, JinSeok;Mu, XiangBin;Rheem, JaeYeol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.67-72
    • /
    • 2013
  • Temperature is a critical parameter in yield improvement for wafer manufacturing. In chemical vapor deposition (CVD) equipment, crack defect in ceramic heater leads to yield reduction, however, there is no suitable ceramic heater fault detection system for conventional CVD equipment. This paper proposes a short-time zero-crossing rate based fault detection method for the ceramic heater in CVD equipment. The proposed method measures the output signal ($V_{pp}$) of RF filter and extracts the zero-crossing rate (ZCR) as feature vector. The extracted feature vectors have a discriminant power and Gaussian mixture model (GMM) based fault detection method can detect fault in ceramic heater. Experimental results, carried out by measured signals provided by a CVD equipment manufacturer, indicate that the proposed method detects effectively faults in various process conditions.

A Study on Ensuring the Safety of Potable UV Space Germicidal Equipment (이동형 UV 공간 살균 기기의 안전성 확보 방안에 관한 연구)

  • Han-Seok Cheong;Chung-Hyeok Kim;Jin-Sa Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.1
    • /
    • pp.94-100
    • /
    • 2024
  • Recently, as interest in personal hygiene has increased due to the community spread of COVID-19 and variant viruses, fixed and potable UV germicidal equipment to sterilize indoor spaces and hand-held UV germicidal equipment to sterilize household items such as masks and mobile phones are continuously being developed and sold. However, the development and sales of the product are difficult because appropriate testing methods have not yet been established. In this situation, if an uncertified product is distributed in the market, it can cause serious harm to consumers. In this study, we investigate the photobiological risks and safety devices against UV exposure of UV germicidal equipment distributed domestically, and propose appropriate test methods for portable UV germicidal equipment based on the research results.

Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment (전기통신설비를 위한 옥내외 겸용 면진테이블 설계)

  • Lee, Chun-Se;Ahn, Hyeong-Joon;Lee, Taek-Won;Son, In-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF

Analysis of Electric Substitution Effects by the Gas Consumption and Characteristics of Gas Cooling System (냉방기기 사용량과 특성을 고려한 가스냉방기기의 전력대체 효과 분석)

  • Park, Rae-Jun;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.669-675
    • /
    • 2012
  • Recently, the amount of electrical heat pump(EHP), a electrical conditioning equipment, is sharply increasing due to the luxury and multi-story trend of building. Accordingly, the cooling load that occupying substantial part of summer electric consumption has increased dramatically, making difficulties in domestic supply of electricity in summer. There are some efforts to replace it with an alternative cooling equipment such as gas heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. It is rare, however, to find studies on the actual effects of GHP on the reduction of summer electricity peak. This study, therefore, estimated the effects of the GHP on the summer electricity peak by the gas consumption and characteristics of gas cooling systems. In addition, electric substitution effects by gas cooling systems were analyzed through case studies in the summer of 2010.

A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application (GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용)

  • Kim, Jong-Seo;Kim, Jin-Tea;Shin, Heung-Sik;Lee, Heung-Jea
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

Electrical Ground Support Equipment(EGSE) Hardware Design for the Communication, Ocean & Metrological Satellite(COMS) (통신해양기상위성 전기적 지상 성능시험 장치 하드웨어 설계)

  • Cho, Young-Ho;Yang, Goon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.269-270
    • /
    • 2007
  • The COMS(Communication, Ocean & Meteorological Satellite) is the geostationary satellite which will be performing three main objectives such as meteorological service, ocean monitoring and Ka-band satellite communications. This paper reports on the hardware architecture of the system electrical ground support equipment(EGSE) for the COMS satellite. EGSE is used to check out satellite during the development prior to lunch. The EGSE represented in this paper consist of two parts. First, I will deal with the OCOE(Overall Check Out Equipment) system which controls and operates the all EGSE system. In second part, we will introduce the SCOE(Specific Check Out Equipment) systems which can test the specific subsystems of the COMS satellite.

  • PDF