• 제목/요약/키워드: Electrical Characteristic Measurement

검색결과 367건 처리시간 0.02초

13.56MHz ICP에서 단일 탐침법에 의한 Ne 가스의 발광특성 연구 (A Study on Emission Characteristics of Ne Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma)

  • 조주웅;최용성;김용갑;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.150-152
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an Ne discharge for pressure from 10 [mTorr] and input RF power 100 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

13.56MHz ICP에서 단일 탐침법에 의한 Ar, Ne 가스의 발광특성 연구 (A Study on Emission Characteristics of Ar, Ne Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma)

  • 조주웅;최용성;김용갑;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.167-170
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an Argon, Ne discharge for pressure from 1 [mTorr] and input RF power 10 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

PBDG 유기초박막의 유전율 측정에 관한 연구 (A Study on the Dielectric Constant Measurement of PBDG Organic Ultra Thin Film)

  • 송진원;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.150-152
    • /
    • 2002
  • This paper, experiment manufactures device of Metal/Poly-$\gamma-Benzyl\;_D-Glutamate$ Organic Films/Metal structure using PBDG and I-V properties and C-F properties. The I-V characteristic is measured that approve voltage from 0 to +2[V] of device and the distance between electrode is larger, could know that small current flow and thin film could know that had insulation property. C-F characteristic has each other affinity between the polarization amount and frequency. Dielectric constant of MIM device could know by dipole that is voluntary polarization of LB film that polarization is happened. The capacitor properties of a thin film is better as the distance between electrodes is smaller.

  • PDF

대퇴부 방사선영상에서 대퇴골 근위부의 형태학적 측정과 골소주의 특성을 이용한 골다공증 예측에 관한 연구 (A Study of Osteoporosis Prediction using Morphological Measuring of Proximal Femoral Part and Trabecular Characteristics Based on Femoral Radiographic Image)

  • 김성민;노승규;노용만
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.823-830
    • /
    • 2010
  • This study was designed to examine the morphological measurement and characteristics of trabecullae based on femoral radiographic image for prediction of osteoporosis. Study subjects were 34 females (average age of 62.1 years) and 6 males (average age of 60.1 years), they were categorized into normal group and osteoporosis group in accordance with the T-score value. Measurement of the bone density of femoral bone was measured with DEXA(Dual Energy X-ray absorptiometry). ROI(Region of interests) was selected on femoral neck and trochanter. Characteristics of trabecullae was analyzed by using the skeletonization analysis of trabecular image. Morphological measurement was analyzed through femoral radiographic image in order to examine the correlation with osteoporosis. The result demonstrated statistically significant correlation between neck cortical thickness, shaft width, shaft cortical thickness, periphery, mean gray level and trabeculae area with BMD average (T-score) of femoral part. The results show that morphological measurement and characteristics of trabecullae based on femoral radiographic images for osteoporosis prediction could be effective.

가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구 (Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor)

  • 허종철;선종호;강동식;정주영;추영배;박정후
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

A Novel Circuit for Characteristics Measurement of SiC Transistors

  • Cao, Guoen;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1332-1342
    • /
    • 2014
  • This paper proposes a novel test circuit for SiC transistors. On-state resistance under practical application conditions is an important characteristic for the device reliability and conduction efficiency of SiC transistors. In order to measure the on-state resistance in practical applications, high voltage is needed, and high current is also necessary to ignite performance for the devices. A soft-switching circuit based on synchronous buck topology is developed in this paper. To provide high-voltage and high-current stresses for the devices without additional spikes and oscillations, a resonant circuit has been introduced. Using the novel circuit technology, soft-switching can be successfully realized for all the switches. Furthermore, in order to achieve accurate measurement of on-state resistance under switching operations, an active clamp circuit is employed. Operation principle and design analysis of the circuit are discussed. The dynamic measurement method is illustrated in detail. Simulation and experiments were carried out to verify the feasibility of the circuit. A special test circuit has been developed and built. Experimental results confirm that the proposed circuit gives a good insight of the devices performance in real applications.

압전 프린트 헤드에 의한 금속프린팅의 미세패턴제어 (Micro Pattern Control of Metal Printing by Piezoelectric Print-head)

  • 윤신용;최근수;백수현;장홍순;서상현
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.147-151
    • /
    • 2011
  • We were analyzed the piezoelectric characteristic for electronics printing to inkjet printing system. These applications were possible use to Actuator, MEMS, FPCB, RFID, Solar cell and LCD color filter etc. Piezoelectric print head is firing from ink droplet control consideration ink viscosity properties. At this time, micro pattern for PCB metal printing was possible by droplet control of piezoelectric driving. These driving characteristics are variable voltage pulse waveform. We are used the piezoelectric analysis software of Finite Element Method (FEM), Piezoelectric design parameters are acquired from piezoelectric analysis, and measurement of piezoelectric. It designed for piezoelectric head to possible electric print pattern of inkjet printing system. For this validity we were established through in comparison with simulation and measurement. Designed piezoelectric specification obtained voltage 98V, firing frequency 10 kHz, resolution 360dpi, drop volume 20pl, nozzle number 256, and nozzle pitch 0.33 mm.

편광유지 광자결정 광섬유 기반 편광 간섭형 진동 센서 (Study on Fiber Polarimetric Vibration Sensor Based on Polarization-Maintaining Photonic Crystal Fiber)

  • 김영석;박경수;이용욱
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.13-18
    • /
    • 2015
  • In this paper, we implemented a polarimetric vibration sensor using a Sagnac birefringence interferometer composed of polarization-maintaining photonic crystal fiber(PM-PCF). By changing the amplitude and frequency of vibration applied to PM-PCF employed as the sensor head of the proposed sensor, sensor responses to various types of vibration were investigated. First, the vibration characteristic of the sensor was explored for a single frequency in a frequency range from 1 to 3000Hz with a cylindrical piezoelectric transducer, and then the sensor response to naturally damped vibration was examined by utilizing a metal cantilever. It was experimentally observed that the sensor output signal was deteriorated by more than 3dB at ~1900Hz in the single frequency vibration measurement with a minimum detectable strain perturbation of ${\sim}1.34n{\varepsilon}/Hz^{1/2}$ at 1500Hz and the peak value of the sensor output signal was proportional to the strength of initially applied stress in the naturally damped vibration measurement.

접지전극을 고려한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Grounding Electrodes)

  • 고희석;김성삼;최종규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.437-439
    • /
    • 2007
  • This paper was analyzed the resistivity change characteristic of mortar model block and concrete that was made earth electrode that's used concrete or basic concrete of building for 1 year. The early resistivity measurement value of concrete model block is higher than mortar model block. But after 1 year the resistivity measurement value of mortar model block is significantly higher than concrete model block. Because depends on time elapsed complete dryness factor of mortar model block that has not gravel is higher than concrete model block. And absorptance and function of mortar mode block was by far outstanding than concrete model block in the data for verification of the amount of contained water and the amount of dryness of mortar model block and concrete model block.

  • PDF

고속철도차량 전동기의 열적 특성 연구 (A Study on Temperature Characteristics for Traction Motor of High Speed Railway)

  • 한영재;김석원;김상수;김기환;구훈모;최종선;김정수
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1123-1127
    • /
    • 2006
  • There are various elements that have influence on safety and reliability of high speed railway. Among them, mechanical characteristics of traction motors are very important. Therefore, we verified that temperature characteristics have influence on damage and durability of these parts. We designed a measurement system for temperature test, and could measure the temperature of each device by the system. As the result of temperature test, we could confirm that the traction motors on Korean High-Speed Train satisfy the criteria. From this test, we get information of the traction motor about the temperature characteristic during running speed and running time.