• Title/Summary/Keyword: Electrical Characteristic Measurement

Search Result 367, Processing Time 0.024 seconds

Characteristic of ITO thin film with plasma surface treatment (플라즈마 표면 처리에 의한 ITO 박막 제작 특성)

  • Kim, Sang-Mo;Son, In-Hwan;Park, Sang-Joon;Kim, Kyung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.404-405
    • /
    • 2007
  • Tin-doped indium thin film is outstanding material among transparent Conductive Oxide (TCO) materials. ITO thin films show a low electrical resistance(<$10^{-4}\;[{\Omega}{\cdot}m]$) and high transmittance(>80%) in the visible range. ITO thin films usually have been deposited on the glass substrate. In order to apply flexible display, the substrate should have the ability to bend and be deposited without substrate heat. Also properties of ITO thin film depend on what kind of substrate. In this study, we prepared ITO thin film on the polycarbonate (PC) substrate by using Facing Target Sputtering (FTS) system. Before deposition of ITO thin film, PC substrate took plasma surface treatment. The electrical and surface properties of as-deposited thin films were investigated by Hall Effect measurement, UV/VIS spectrometer and the surface property of substrate is investigated by Contact angle measurement.

  • PDF

The Improvement of Accuracy and Measurement Speed in the Low Current Measurement System (저전류 측정 시스템에서의 정밀도 및 측정 속도 향상)

  • Baek, Wang-Ki;Choi, In-Kyu;Park, Jong-Sik;Lee, Kyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.550-553
    • /
    • 2002
  • A source meter is a basic instrument to perform a measurement of DC characteristic of semiconductor devices. the source meter can be used as variable voltage source, variable current source, voltage meter, or current meter. The accuracy of the low current measurement can be improved with the compensation of leakage current and charge and discharge current. In the low current measurement, the RC time constant is extremely big, so the measurement speed is very low. In this thesis, the analysis of the behavior of the measurement current according to the RC time constant and output capacitance and the method to accelerate the measurement speed.

  • PDF

Individual Load Select and Characteristic Experiment for Load Model Construction (부하모델 구축을 위한 개별부하선정 및 특성실험에 관한 연구)

  • Ji, P.S.;Lee, J.P.;Lim, J.Y.;Park, S.W.;Kim, K.D.;Wee, W.S.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.325-327
    • /
    • 1999
  • In this research, selection of component load and measurement device is considered for accurate component load modeling. The procedure of component load characteristic experiments is also presented.

  • PDF

A Study on Water Tree Degradation Using Image Measurement in Underground Power Cables (화상계측에 의한 지중 전력케이블의 수트리 열화에 관한 연구)

  • Kim, Duck-Keun;Lim, Jang-Seub;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1063-1068
    • /
    • 2000
  • Water treeing in underground distribution power cable is not easy to observe by nondestructive method and it has very complex patterns. This study describes the principles and practices of a continuous observation of initiation and growth of tree in polymeric insulation material using an image measurement technique. Using this technique we could observe water tree and the growing process of electrical tree due to the water tree and the growing process of electrical tree due to the water tree. All of these growing process is analyzed quantitatively by image measurement program composed of borland c++. We fabricated the thin film type specimen to observe water tree easier and also the needle electrode was prepared by etching method using electrolytes. Initiation and the growth of three was observed somewhat different depending on the applied voltage and the water electrode. AgNO$_3$solution electrode accelerates the initiation and the growth of water tree, compared to those of distilled water electrode. The water and the electrical tree occurred by water tree has discontinuous growth characteristic.

  • PDF

RF Channel Characteristics of the Medium-voltage Power Line for PLC (전력선통신을 위한 중 전압용 전력선의 RF채널 특성)

  • Kim, Seon-Hyo;Kim, Gwan-Ho;Lee, Hyeong-Cheol;Sin, Cheol-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

Study on The Small-Gap Measuring System for Gas Velocity Measurement of $SF_6$ Gas Circuit Breaker ($SF_6$ 가스차단기에서 가스 속도측정을 위한 Small-Gap 측정시스템에 관한 연구)

  • Kim Hong-Kyu;Dong Song-Ki;Lee Woo-Young;Park Kyong-Yop;Chong Jin-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.3
    • /
    • pp.139-144
    • /
    • 2005
  • [ $SF_6$ ] gas circuit breakers are widely used short circuit current interruption in EHV or UHV power system. For a $SF_6$ gas circuit breaker development, the $SF_6$ gas velocity measurement is necessary during $SF_6$ circuit breaker's trip operation. Small-gap flashover characteristics are used for this measurement. So, small-gap measuring system which will be used to develope GCB should be developed. This study shows the characteristic analysis and experimental results of small-gap measuring system.

Thermal Conductivity Characteristic of Carbon Nanotube Composites and XLPE Insulator (탄소나노튜브 복합체와 XLPE 절연체의 열전도도 특성)

  • Yang, Jong-Seok;Kook, Jeong-Ho;Park, Noh-Joon;Nah, Chang-Woon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.160-161
    • /
    • 2006
  • To Improve the mean-life and the reliability of power cable, we have investigated thermal conductivity of XLPE insulator and semiconducting materials in l54[kV] underground power transmission cable. Specimens were made of sheet form with the nine of specimens for measurement. Thermal conductivity were measured by Nano Flash Diffusivity thermal conductivity measurement temperature ranges of XLPE insulator were from 20[$^{\circ}C$] to 90[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/mm]. In case of semiconducting materials. the measurement temperature ranges of thermal conductivity were from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min].

  • PDF

The three-dimensional measurement and analysis for 828nm light emitted from plasma display panel by scanned point detecting method(SPDM) (Scanned point detecting method(SPDM)에 의한 플라즈마 디스플레이 패널의 828nm 광에 대한 3차원 측정과 해석)

  • 최훈영;정재완;이승걸;이석현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.284-287
    • /
    • 2000
  • We analyzed the 3-dimensional discharge characteristic in plasma display panel(PDP) cell using the 3-dimensional emission distribution of 828nm light measured by scanned point detecting method(SPDM). The emitted light distributions on the ITO electrode show the stronger light intensity near to the electrode gap than outside. Also, 828nm light is widely detected outside of the bus electrode. We consider that measurement using new SPDM is effective to analyze the discharge physics and propose the new panel structures.

  • PDF

A Study on Measurement for Earth Resistance of Steel Structure (철탑접지저항 측정에 관한 연구)

  • 박석탁;김시영
    • 전기의세계
    • /
    • v.22 no.6
    • /
    • pp.33-51
    • /
    • 1973
  • To lower the earth resistance shall be one of the most effective method for the prevention of lightening damage on power transmission line. In this report, in order to investigate various characteristic necessary to lowering the earth resistance, the following experiments have been made at 154KV U1San-PoHang T/L, 154KV YoSu-SoonChun T/L and so on. 1. Measurement of Earth specific resistance, 2. Efficiency of Earthing of concrete foundation for steel structure., 3. Efficiency of Earthing with counter poise., 4. Compound impulse test with foundation of steel structure and counter poise. With the above investigate a guidance have been prepared for the effective work-performance of steel structure.

  • PDF

Characteristic Analysis of Transformer Temperature for High Speed Train (고속철도차량의 변압기 온도 특성 분석)

  • Han, Young-Jae;Kim, Ki-Hwan;Kim, Yeong-Guk;Park, Chun-Su;Kim, Seog-Won;Mok, Jin-Yong;Lee, Su-Gil;Lee, Seong-Ho;Kim, Jong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1595-1597
    • /
    • 2005
  • In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Therefore, after on-line measurement system was constructed in vehicle, oil temperature and tank temperature were measured on real-time. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measurement system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measurement system, KHRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.

  • PDF