• Title/Summary/Keyword: Electrical Characteristic Measurement

Search Result 367, Processing Time 0.032 seconds

Synthesis and Quality of Cr-doped AIN Thin Films Grown by RF Sputtering

  • Quang, Pham Hong;Hung, Tran Quang;Dai, Ngo Xuan;Thanh, Tran Hoai;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.149-151
    • /
    • 2007
  • The AlCrN films were grown by RF reactive sputtering method under the selected conditions. The Cr concentration was varied by the number of Cr pieces placed on the Al target. The sample quality has been studied by XRD, Auger spectroscopy, optical absorption and electrical resistant measurements. The XRD and Auger results show that the samples consist of a major phase with the $Al_{1-x}Cr_xN$ formula, which has a hexagonal structure, and a few percents at. of oxygen, which may form $Al_2O_3$. There exist the Cr clusters in the samples with high concentration of Cr. The optical absorption measurement provides the information about the band gap that relates strongly to the quality of samples. The quality of samples is also clearly reflected in electrical measurement, i.e., the temperature dependence of resistance exhibits a semiconductor characteristic only for the samples that have no Cr cluster. In these cases, the values of ionization energies $E_a$ can be derived from R(T) plots by using the function R(T) = Ro exp $(E_a/k_BT)$.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • 윤헌주;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

Comparison of Electromagnetic Force Characteristics and Experiment of Pitching Moment in Permanent Magnet Linear Synchronous Motor According to the Moving Iron Core and Stator Topology (철심형 이동자와 고정자의 형상에 따른 영구자석 선형 동기전동기의 전자기력 특성 비교 및 피칭 모멘트 실험)

  • Lee, Seung-Han;Cho, Han-Wook;Khim, Gyungho;Oh, Jeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1695-1702
    • /
    • 2015
  • This paper presents the characteristic analysis and experiment of force characteristics in permanent magnet linear synchronous motor for accuracy prediction of linear motion machine tools. In particular, the pitching moment resulting from attraction force ripple has been analysed and tested. Firstly, we analysed the characteristics of detent force, attraction force, and pitching moment in permanent magnet linear synchronous motor according to the design techniques such as auxiliary teeth, chamfering, and permanent magnet skewing. In addition, we suggested the experimental set for measurement of pitching moment. Finally, the results from measurement shows the good agreement with those obtained from finite element analysis results.

Characteristic of the Wear and Lubrication using the Friction Froce Measurement in CMP Process (CMP 공정에서 마찰력 측정을 통한 마멸 및 윤활 특성에 관한 연구)

  • Park, Boum-Young;Kim, Hyoung-Jae;Seo, Heon-Deok;Kim, Goo-Youn;Lee, Hyun-Seop;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.231-234
    • /
    • 2004
  • Chemical mechanical polishing(CMP) process was studied in terms of tribology in this paper. CMP performed by the down force and the relative motion of pad and wafer with the slurry is typically tribological system composed of friction, wear and lubrication. The piezoelectric quartz sensor for friction force measurement was installed and the friction force was detected during CMP process. Various coefficient of friction was attained and analyzed with the kind of pad, abrasive and the abrasive concentration. The lubrication regime is also classified with ${\eta}v/p(\eta,\;v\;and\;p;$ the viscosity, relative velocity and pressure). Especially, the co-relation not only between the friction force and the removal per unit distance but also between the coefficient of friction and within-wafer-nonuniformity was estimated.

  • PDF

Review of Electrical Characterization of Ceramic Thin Films for the Next Generation Semiconductor Devices (차세대 반도체 소자용 세라믹 박막의 전기적 분석 방법 리뷰)

  • Lee, Donghyun;Yang, Kun;Park, Ju-Yong;Park, Min Hyuk
    • Ceramist
    • /
    • v.22 no.4
    • /
    • pp.332-349
    • /
    • 2019
  • Ceramic thin films are key materials for fundamental electronic devices such as transistors and capacitors which are highly important for the state-of-the-art electronic products. Their characteristic dielectric properties enable accurate control of current conduction through channel of transistors and stored charges in capacitor electrodes. The electronic conduction in ceramic thin films is one of the most important part to understand the electrical properties of electronic device based on ceramic thin films. There have been numerous papers dealing with the electronic conduction mechanisms in emerging ceramic thin films for future electronic devices, but these studies have been rarely reviewed. Another interesting electrical characterization technique is one based on electrical pulses and following transient responses, which can be used to examine physical and chemical changes in ceramic thin films. In this review, studies on various conduction mechanisms through ceramic thin films and electrical characterization based on electric pulses are comprehensively reviewed.

Secondary Transition Characteristics of Induced Displacement Current (유기된 변위전류의 2차 전이특성)

  • Kim, Sung-Jin;Chang, Hun;Kim, Young-Heun;Choi, Young-I1;Gu, Hal-Bon;Chung, Hun-Sang;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1693-1695
    • /
    • 2000
  • In this paper with deposition 8A5H induce monolayers which has photoisomerization response displacement current was detected by photoisomerization and the amplifier was designed in order to amplify detected displacement current and then secondary current characteristic was measured. The experimental results are as following: In case of ultraviolet(${\lambda}_1$) and visible(${\lambda}_2$) irradiation on 8A5H induce monolayers depositioned on board the peak of current was detected about 9[fA]. Displacement current amplified as secondary transition form was measured but there was any particular reaction for detailed and accurate measurement restruction of the circuit is required.

  • PDF

Characteristics of Motion-blur Free TFT-LCD using Short Persistent CCFL in Blinking Backlight Driving

  • Han, Jeong-Min;Ok, Chul-Ho;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.166-169
    • /
    • 2007
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive TN-LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by counting between on time and off time for video signal input during 1 frame (16.7 ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by CCFL blinking drive and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

A Study on Analysis of Thyristors by the Half-sine wave Voltage (Thyristor의 반파전압에 의한 특성분석에 관한 연구)

  • Park, H.C.;Won, H.J.;Han, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1327-1329
    • /
    • 2000
  • The thyristor among the power-semi-conductor elements, which has large current capacity and high voltage, is used widely nowadays. When the thyristor was being used to the long time, this element may be able to arise the system trip caused by changing the characteristic and dropping the performance. Therefore, it would be necessary to analyze the characteristic of element to maintain the stable operation of the system. In oder to analyze this characteristic, it would be need to test forward direction, reverse direction and leakage current by supplying the half-sine wave voltage. Among these testing, transient current condition is generated from the testing of leakage current. This transient current may be the main factor of the error in the precise measurement of leakage current. Therefore, this paper analyzes the relationship between supply voltage and transient current in measuring leakage current of the SCR, and then suggests the condition and cause of transient current as appearing the leakage current in the testing the leakage current.

  • PDF

Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer (식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.