• 제목/요약/키워드: Electrical Activity of the Heart

검색결과 77건 처리시간 0.028초

직물 전극의 형상 특성이 자계 유도성 전도율 기반의 비접촉식 심장활동 센싱에 미치는 효과의 분석 (An Analysis on the Effect of the Shape Features of the Textile Electrode on the Non-contact Type of Sensing of Cardiac Activity Based on the Magnetic-induced Conductivity Priciple)

  • 지선옥;이영재;구혜란;강선아;박희정;김경섭;이주현;이정환
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.803-810
    • /
    • 2013
  • The purpose of this research is to analyze the effect of shape of the inductive textile electrode on the non-contact heart activity sensing, based on the magnetic-induced conductivity principle. Four types of the inductive textile electrodes were determined according to the combinations of the two shape features. A fiber-metal hybrid-typed conductive thread was developed and applied to materialization of the textile electrodes by embroidery method. The heart activity was extracted through the textile electrode sewn on a T-shirt. The experiments were implemented to constantly measure the heart activity for 20 seconds, in each case of 5 healthy male subjects. The heart activity signals acquired in each type of the inductive textile electrode were analyzed, 1)by drawing a comparison of morphology with those of ECG signal (LeadII), and 2)by calculation of the normalized mean and standard deviation of magnitude of the heart activity signals. The analysis resulted that the relatively better quality of signals were acquired in the 'square' types in the matter of whole shape, while the better results were obtained in 'donut' types in the matter of center hole. Accordingly, the relatively best quality of signals was obtained in the case of 'Square-Donut' type of the inductive textile electrode.

심전도 자동 진단 알고리즘 및 장치 구현(III) - 심방 및 심실활동 검출기 (An implementation of automated ECG interpretation algorithm and system(III) - Detector of atrium and ventricle activity)

  • 권혁제;이정환;윤지영;최성균;이준영;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.288-292
    • /
    • 1996
  • This paper describes far the detection of heart event that is, QRS complex and P wave which are result from heart activity. The proposed QRS detection method by using the spatial velocity was identified as having the 99.6% detection accuracy as well as fast processing time. Atrial flutter, coupled P wave, and noncoupled P wave as well as atrial fibrillation could be detected correctly by three different algorithms according to their origination farm. About 99.6% correction accuracy coupled P wave could be obtained and we could be found that most detection errors are caused by establishing wrong search interval.

  • PDF

심장기능(心臟機能)에 미치는 Bicarbonate-Buffer의 중요성(重要性) : Buffer 제거(除去)에 의(依)한 유리심방(遊離心房)의 수축성(收縮性), 막전위(膜電位) 및 ATP 함량(含量)의 변동(變動) (THE IMPORTANCE OF BICARBONATE-BUFFER ON CARDIAC FUNCTION: Contractility, Membrane Potentials and ATP Content of Isolated Atria in the Absence of External Buffers)

  • 고계창;한대섭;정지창
    • 대한약리학회지
    • /
    • 제8권2호
    • /
    • pp.63-69
    • /
    • 1972
  • The effects of omission of buffers from Krebs-Ringer medium on contractile activity, membrane potentials and ATP content of electrically stimulated isolated rat atria were investigated. 1) Contractile status: A rapid and marked depression of the contractile activity of atria occurred when buffer-free medium was substituted for the normal Krebs-Ringer medium. 2) Electrical status: The omission of buffers from medium did not alter the resting or action potential magnitudes of atria. However, the action potential duration was on initial increase followed by a decrease in the buffer-free medium. 3) ATP concentration: The omission of buffers from medium resulted in a marked decrease in the ATP levels of atria. It has been also found in the present study that bicarbonate buffer plays an important role for the maintenance of the contractility and ATP levels of the heart. The contractile depression by the omission of buffers was not directly associated with electrical alterations in resting or action potentials of the heart. In the absence of bicarbonate-buffer, glucose no longer plays to maintain the contractile activity and the ATP levels of rat atria.

  • PDF

새로운 비관혈적 태아 저산소증 진단 방법개발에 관한 연구 (Development of a New Non-invasive Fetal Hypoxia Diagnosis System)

  • 이전;이경중
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권11호
    • /
    • pp.495-501
    • /
    • 2006
  • Diagnostics of unborn baby is mainly aimed at prediction and detection of occurrence of intrauterine hypoxia. Consequences resulting from fetal hypoxia appear in its heart activity. In this study, we have developed a new non-invasive system for fetal hypoxia diagnosis which provides systolic time interval(STI) parameters on the basis of analysis of electrical and mechanical heart activity together. For this we have worked on 1) the proper lead system for the acquisition of abdominal ECG, 2) the independent component analysis based signal processing and fetal ECG separation, 3) the development of a hardware which consists of an abdominal ECG amplifying module and an ultrasound module and 4) the detection of characteristic points of FECG and Doppler signal and the extraction of diagnostic parameters. The developed system was evaluated by the clinical experiments in which 33 subjects were participated. The acquired STI by the system were distributed within the ranges from the well-established invasive results of other researchers. From this, we can conclude that the developed non-invasive fetal hypoxia diagnosis system is useful.

Accidental ingestion of E-cigarette liquid nicotine in a 15-month-old child: an infant mortality case of nicotine intoxication

  • Seo, An Deok;Kim, Dong Chan;Yu, Hee Joon;Kang, Min Jae
    • Clinical and Experimental Pediatrics
    • /
    • 제59권12호
    • /
    • pp.490-493
    • /
    • 2016
  • Electronic cigarettes are novel tobacco products that are frequently used these days. The cartridge contains liquid nicotine and accidental poisoning, even with a small oral dose, endangers children. We present here a mortality case of a 15-month-old child who ingested liquid nicotine mistaking it for cold medicine. When the emergency medical technicians arrived, she was found to have pulseless electrical activity. Spontaneous circulation was restored after approximately 40 minutes of cardiopulmonary resuscitation. The cotinine level in her urine was 1,716 ng/mL. Despite intensive supportive care, severe anoxic brain injury was found on computed tomography and the child ultimately died. This fatality highlights the need for public health efforts to minimize such accidents.

심장 질환 진단을 위한 데이터 마이닝 기법 (Data Mining Approach for Diagnosing Heart Disease)

  • 노기용;류근호;이헌규
    • 감성과학
    • /
    • 제10권2호
    • /
    • pp.147-154
    • /
    • 2007
  • 심장의 활동을 기록한 심전도는 심장의 상태에 대한 가치 있는 임상 정보를 제공한다. 지금까지 심전도를 이용한 심장 질환 진단 알고리즘에 대한 많은 연구가 진행되어 왔으나, 심장 질환에 대한 국내 진단 결과의 부정확성 때문에 외국의 진단 알고리즘을 사용하고 있다. 이 논문에서는 원시 심전도 데이터로부터 심장 질환 진단의 파라미터인 ST-segment 추출 방법을 제안한다. ST-segment는 관상동맥 질환 예측에 활용되므로 데이터마이닝의 분류기법을 적용하여 질환을 예측한다. 또한 연관규칙 마이닝을 통해 환자들의 임상 데이터로부터 심장 질환자들의 임상적 특징을 예측한다.

  • PDF

정전 용량성 결합 전극을 이용한 웨어러블 심전도 측정 시스템 설계에 관한 연구 (Study of the Wearable Electrocardiogram Measuring System using Capacitive-coupled Electrode)

  • 이재호;이영재;이강휘;강승진;김경남;박희정;이정환
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1448-1454
    • /
    • 2014
  • In this study, a new type of electrode device is implemented to measure the capacitance energy and interpret it as the ECG (Electrocardiogram) data. The main idea of this new electrode system is to estimate the capacitance on the skin by assembling a capacitive-coupled circuits and translate into the ECG signal. To measure the coupling energy and estimate the aquired data in terms of heart activity, the capacitive-coupled electrode is garmented with fabrics in the form of a chest band or a vest jacket. To compare the ECG data from the capacitive-coupled electrode with the conventional electrode(Ag-AgCl) system, the corelation coefficient between two signals is computed as 0.9517. Thus, we can conclude the fact that capacitive-coupled electrode system can measure a person's heart activity without any contact to his or her skin and can the interpreted as the ECG data.

원적외선 온열이 인체 자율신경기능에 미치는 영향에 관한 연구 (A Study on Human Autonomic Nervous System Activities by Far-Infrared Ray Hyperthermia)

  • 박찬욱;장윤호;민세동;강세구;이충근;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.623-628
    • /
    • 2004
  • 본 논문에서는 원적외선 온열효과가 자율 신경계에 미치는 영향을 심박변동(HRV)을 이용하여 평가 하였다. 측정된 심박변동신호를 FFT 의한 전력스펙트럼을 구함으로써 자율 신경계의 반응 특성을 고찰하고 Poincare plot 분석 방법을 이용하여 결과를 비교 분석하였다. 실험을 통해 심박변동 신호분석해보면 원적외선 온열에 노출되기 전에 비해 노출된 후에 매우 복잡한 모습임을 관찰 할 수 있었는데 이것은 자율신경계가 관여하는 심혈관계 제어 메커니즘이 원적외선 온열에 노출되기 전보다 노출된 후에 더욱 복잡함을 반영하는 것으로 분석된다.

심전도신호의 R-R 간격을 이용한 부정맥 구간 검출 알고리즘 (Detection Algorithm of Cardiac Arrhythmia in ECG Signal using R-R Interval)

  • 김경호;이상운;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.85-89
    • /
    • 2014
  • 심전도(electrocardiography, ECG)는 심장박동을 할 때, 발생하는 탈분극과 재분극으로 심장의 전위변화를 시간의 흐름에 따라 파형으로 표현한 것이다. 의료기관에서는 심전도신호를 이용하여 환자의 심장질환을 진단한다. 일반적으로 사람의 정상적인 심장박동수는 1분에 60-100회 이다. 만약 정상적인 심장박동 수보다 느리거나 빠르다면 부정맥이라고 한다. 본 논문에서는 심전도신호에서 R-peak를 검출하여, R-R 간격을 구하고 부정맥 중에 서맥(bradycardia)과 빈맥(tachycardia) 구간을 검출하는 알고리즘을 제안하고 모의실험을 하였다.