• 제목/요약/키워드: Electrical Accident

검색결과 516건 처리시간 0.026초

식료품 제조업 유해·위험요인 개선율과 재해율의 관계 분석을 통한 점검 체크리스트 개발 (Development of Inspection Checklist through the Analysis of the Relationship between the Risk Improvement Ratio and the Accident Ratio in Food Manufacturing Industry)

  • 유호형;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권4호
    • /
    • pp.47-53
    • /
    • 2023
  • In the inspection of workplace hazards/risk factors by specialized institutions dedicated to safety management, inspection reports vary based on the inspectors, who lack the authority to enforce improvement of workplace hazards/risk factors. Thus, improvement and accident rates remain steady without decreasing. This study performed a regression analysis on the relationship between improvement and accident rates of categorized inspection items by classifying hazards/risk factors from inspection reports submitted by a specialized safety management institution in Chungbuk after inspecting 10 food and beverage manufacturers over the past three years. The hazards/risk factors were classified into five categories: mechanical, electrical, chemical, human, and environmental. The regression analysis revealed that the improvement rate of hazards/risk factors inspected by the specialized safety management institution influenced accident rates. To enhance improvement rates based on these findings, this study prioritized the correction of the five most frequently cited inspection items with the lowest improvement rates in each area. Based on these inspection items, this study suggested a checklist for use in workplace safety inspections of food manufacturers. This proposed checklist is expected to reduce accident rates in food manufacturing facilities. Currently, guidance and inspection of workplaces are mainly focused on accident rates rather than correcting hazards/risks. Thus, accident rates remain unchanged as workplace risks are inadequately improved according to the unique characteristics of each workplace. When conducting workplace guidance and inspection, policy measures and inspection methods are warranted to increase the improvement rate of hazards/risks.

감전사고 예방을 위한 지중함 구조 및 절연 관련 시설기준 개발에 관한 연구 (A Study on Electric-technical Regulation of Handhole Structure and Insulation for Preventing Electrical Shock Accident)

  • 김기현;차송희;손이조
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1303-1308
    • /
    • 2017
  • The underground electricity distributions are significantly increased because of the urbanization accompanied by rural area developments. However, it has also been increased the safety accidents such as an electric shock around the handhole where the underground cables are connected to each other. This paper provides the base materials on the necessity to amend the installation regulation for securing the insulation and structure strength of handholds using the cast iron or fiberglass reinforced plastic. Article 137 in the judgement regulation for the Korea electro-technical regulation which is one of the installation regulations for handhole is amended and announced in 2017 by being based on the materials in this paper. It is expected to continually reduce the electric shock occurrence around handhole by considering the amended installation regulation.

UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구 (A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array)

  • 최명일;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

철제펜스로 지지된 동력배선의 단락.지락에 의한 전기화재 발생 개연성 연구 (A Study on the Possibility of Electrical Fires due to the Short Circuit and Ground Fault of Power Cable Supported by an Iron Fence)

  • 김정훈;박병기;송종혁;정기창
    • 한국안전학회지
    • /
    • 제22권6호
    • /
    • pp.41-45
    • /
    • 2007
  • Short circuit and ground fault account for the primary causes of electrical fires. In this research, real-scale experiments were conducted to assess the possibility of electrical fires due to these causes. The experiment conditions were identical with an actual fire accident, in which the power cable was supported by an iron fence. The purposes of this research are to investigate the short circuit caused by wire cutting, the conductivity of the iron fence depending on its coating conditions, and the ground fault of one wire or two wires in an effort to reconstruct the fire accident. The test results show that, owing to the instant operation of circuit breaker in the moment of short circuit or ground fault, the generated ignition energy is far less than necessary to start an ignition. Therefore it is concluded that electrical fire is highly unlikely if the electric system is protected by a circuit breaker with normal functions.

전기공사 안전사고 사례 분석 (A case study for safety-accident of electrical construction)

  • 김효진;황민수;김현진;박일순;김종인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2085-2086
    • /
    • 2008
  • 본 논문에서는 전기공사 시공현장에서 일어나는 재해사고에 대한 분석을 하였으며, 전기공사 주요 현장에 대한 안전사고사례를 예를 들어 추후 유사사고 또는 동동의 사고 예방을 하는데 기여 하고자하며, 전기공사 분야별 안전사고를 중심으로 분석하였다.

  • PDF

반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템 (Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Investigation of a Hydrogen Mitigation System During Large Break Loss-Of-Coolant Accident for a Two-Loop Pressurized Water Reactor

  • Dehjourian, Mehdi;Sayareh, Reza;Rahgoshay, Mohammad;Jahanfarnia, Gholamreza;Shirani, Amir Saied
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1174-1183
    • /
    • 2016
  • Hydrogen release during severe accidents poses a serious threat to containment integrity. Mitigating procedures are necessary to prevent global or local explosions, especially in large steel shell containments. The management of hydrogen safety and prevention of over-pressurization could be implemented through a hydrogen reduction system and spray system. During the course of the hypothetical large break loss-of-coolant accident in a nuclear power plant, hydrogen is generated by a reaction between steam and the fuel-cladding inside the reactor pressure vessel and also core concrete interaction after ejection of melt into the cavity. The MELCOR 1.8.6 was used to assess core degradation and containment behavior during the large break loss-of-coolant accident without the actuation of the safety injection system except for accumulators in Beznau nuclear power plant. Also, hydrogen distribution in containment and performance of hydrogen reduction system were investigated.

교통사고 데이터의 마이닝을 위한 연관규칙 학습기법과 서브그룹 발견기법의 비교 (Comparison of Association Rule Learning and Subgroup Discovery for Mining Traffic Accident Data)

  • 김정민;류광렬
    • 지능정보연구
    • /
    • 제21권4호
    • /
    • pp.1-16
    • /
    • 2015
  • 교통사고의 원인을 규명하고 미래의 사고를 방지하기 위한 노력의 일환으로 데이터 마이닝 기법을 이용한 교통 데이터 분석의 연구가 이루어지고 있다. 하지만 기존의 교통 데이터를 이용한 마이닝 연구들은 학습된 결과를 사람이 이해하기 어려워 분석에 많은 노력이 필요하다는 문제가 있었다. 본 논문에서는 많은 속성들로 표현된 교통사고 데이터로부터 유용한 패턴을 발견하기 위해 규칙 학습 기반의 데이터 마이닝 기법인 연관규칙 학습기법과 서브그룹 발견기법을 적용하였다. 연관규칙 학습기법은 비지도 학습 기법의 하나로 데이터 내에서 동시에 많이 등장하는 아이템(item)들을 찾아 규칙의 형태로 가공해 주며, 서브그룹 발견기법은 사용자가 지정한 대상 속성이 결론부에 나타나는 규칙을 학습하는 지도학습 기반 기법으로 일반성과 흥미도가 높은 규칙을 학습한다. 규칙 학습 시 사용자의 의도를 반영하기 위해서는 하나 이상의 관심 속성들을 조합한 합성 속성을 만들어 규칙을 학습할 수 있다. 규칙이 도출되고 나면 후처리 과정을 통해 중복된 규칙을 제거하고 유사한 규칙을 일반화하여 규칙들을 더 단순하고 이해하기 쉬운 형태로 가공한다. 교통사고 데이터를 대상으로 두 기법을 적용한 결과 대상 속성을 지정하지 않고 연관규칙 학습기법을 적용하는 경우 사용자가 쉽게 알기 어려운 속성 사이의 숨겨진 관계를 발견할 수 있었으며, 대상 속성을 지정하여 연관규칙 학습기법과 서브그룹 발견기법을 적용하는 경우 파라미터 조정에 많은 노력을 기울여야 하는 연관규칙 학습기법에 비해 서브그룹 발견기법이 흥미로운 규칙들을 더 쉽게 찾을 수 있음을 확인하였다.