• Title/Summary/Keyword: Electrical Accident

Search Result 519, Processing Time 0.028 seconds

The Protective Countermeasure of Water Purifier PCB according to Abnormal Voltage (이상전압에 따른 정수기 PCB의 보호대책)

  • Kim, Dong-Ook;Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Hyang-Kon;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.64-70
    • /
    • 2007
  • The electrical accident results from an insulation blackdown by over-voltage, an overheating by the excess of allowable current, a deterioration performance by the passage of time, and so on. This paper discusses how to improve the power control system of PCB in water purifier. The protecting device of present power supply control system in water purifier is composed of the varistor device which acts only for impulse-type surges. So the present system can not be protected others except the surge of impulse-type. The newly-suggested power control system in this paper is designed to protect the system by disconnecting power supply through SSR(Solid State Relay) if the value of input voltage is exceeded the setting value.

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

A Study on Crane Wire Rope Flaws Signal Processing Using Discrete Wavelet Transform (Wavelet 변환을 이용한 크레인 와이어 로프 결함 신호처리에 관한 연구)

  • Min, Jeong-Tak;Sohn, Dong-Seop;Lee, Jin-Woo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.155-159
    • /
    • 2002
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, wire rope of crane is important component to container transfer. If it happens wire rope failures in operating, it may lead to safety accident, economic power loss by productivity decline, competitive power decline of container terminal and so on. To solve this problem, we developed wire rope fault detecting system as a portable instrument, and this system is consisted of 3 parts that fault detecting part using hall sensor, permanent magnets and analog unit, and digital signal processing part using data acquisition card, monitoring part using wavelet transform, denoising method. In this paper, a wire rope is scanned by this system after makes several broken parts on the surface of wire rope artificially. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data that was used filter. In practical applications of denoising, it is shown that wavelet pursue it with little information loss and smooth signal display. It is verified that the detecting system by denoising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension of wire ropes exchange period and could competitive power. Also, this system is possible to apply in several fields like that elevator, lift and so on.

  • PDF

A Study on Development of a New Algorithm to Solve Load Flow for Distribution Systems (배전계통조류계산을 위한 새로운 알고리즘에 관한 연구)

  • Moon, Young-Hyun;Yoo, Sung-Young;Choi, Byoung-Kon;Ha, Bock-Nam;Lee, Joong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.918-922
    • /
    • 1998
  • With the development of industry, the qualitical advancement of power is needed. Since it is placed in the end step of power system, the fault at the distribution system causes some users blackout directly. So if the fault occurs, quick restoration is very important subject and, for the reason, induction of the distribution automation system is now being progressed briskly. For the quick restoration of the faulted distribution system, the load shedding of the blackout-area must be followed, and the other problems like the shedded load, faulted voltage and the rest may cause other accident. Accordingly load shedding must be based on the precise calculation technique during the distribution system load flow(dist flow) calculation. In these days because of its superior convergence characteristic the Newton-Raphson method is most widely used. The number of buses in the distribution system amounts to thousands, and if the fault occurs at the distribution system, the speed for the dist flow calculation is to be improved to apply to the On-Line system. However, Newton-Raphson method takes much time relatively because it must calculate the Jacobian matrix and inverse matrix at every iteration, and in the case of huge load, the equation is hard to converge. In this thesis. matrix equation is used to make algebraical expression and then to solve load flow equation and to modify above defects. Then the complex matrix is divided into real part and imaginary part to keep sparcity. As a result time needed for calculation diminished. Application of mentioned algorithm to 302 bus, 700 bus, 1004 bus system led to almost identical result got by Newton-Raphson method and showed constant convergence characteristic. The effect of time reduction showed 88.2%, 86.4%, 85.1% at each case of 302 bus, 700 bus system 86.4%, and 1004 bus system.

  • PDF

A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal (스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구)

  • Woo, Seung Woo;Park, J.M.;Hyun, B.S.;Nam, J.W.;Park, W.S.;Kim, J.P.;Cho, Y.J.;Goh, J.M.;Park, N.K.
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

Analysis and Risk Prediction of Electrical Accidents Due to Climate Change (기후환경 변화에 따른 전기재해 위험도 분석)

  • Kim, Wan-Seok;Kim, Young-Hun;Kim, Jaehyuck;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.603-610
    • /
    • 2018
  • The development of industry and the increase in the use of fossil fuels have accelerated the process of global warming and climate change, resulting in more frequent and intense natural disasters than ever before. Since electricity facilities are often installed outdoors, they are heavily influenced by natural disasters and the number of related accidents is increasing. In this paper, we analyzed the statistical status of domestic electrical fires, electric shock accidents, and electrical equipment accidents and hence analyzed the risk associated with climate change. Through the analysis of the electrical accidental data in connection with the various regional (metropolitan) climatic conditions (temperature, humidity), the risk rating and charts for each region and each equipment were produced. Based on this analysis, a basic electric risk prediction model is presented and a method of displaying an electric hazard prediction map for each region and each type of electric facilities through a website or smart phone app was developed using the proposed analysis data. In addition, efforts should be made to increase the durability of the electrical equipment and improve the resistance standards to prevent future disasters.

Development of Embedded Lane Detection Image Processing Algorithm for Car Black Box (차량용 블랙박스를 위한 임베디드 차선감지 영상처리 알고리즘 개발)

  • Yi, Soo-Yeong;Ryu, Ji-Hyoung;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2942-2950
    • /
    • 2010
  • Car black box helps to investigate the cause of accident by recording time, position and videos as well as shock information. In addition, the car black box need a function to support safe driving for preventing accident. The representative driving support function is a lane departure warning. In order to implement the function, it is necessary to carry out the image processing to detect the lane first. The image processing algorithm requires computational burden to handle so much data and complicated structure of algorithm. This paper describes the efficient image processing algorithm with relatively low amount of computation for car black box embedded platform to detect lanes from the real-time lane image.

Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA (ETA를 통한 연구실험실 콘센트회로의 전기재해 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

Smart Manhole Device for Underground Facility Management (지중 시설물 관리를 위한 스마트 맨홀 디바이스)

  • Kim, Jong-Duk;Han, Seung-Heon;Kim, Yong-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.996-1003
    • /
    • 2019
  • The undergrounding of diverse ground facilities has led to a decrease in issues, such as foul smell of water supply systems and wastewater, a fall of telephone poles, electromagnetic waves and breaking of wires caused by a railway work. On the other hand, there are new issues, including a fall accident, explosion affected by flammable gas, a choking accident by harmful gas and a lack of oxygen concentration, a fire coming from high-tension wire heating and flooding in the manhole. Besides, these issues damage the civil society and are an anxiety to public safety. Therefore, this paper is focused on a smart manhole device for stable communication environments inside and outside the manhole and wireless communication with various devices for managing facilities in the manhole, and aims to make a contribution to public safety by suggesting a direction of future underground facility management.

Emergency Rescue Guidance Scheme Using Wireless Sensor Networks (재난 상황 시 센서 네트워크 기반 구조자 진입 경로 탐색 방안)

  • Joo, Yang-Ick
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1248-1253
    • /
    • 2019
  • Using current evacuation methods, a crew describes the physical location of an accident and guides evacuation using alarms and emergency guide lights. However, in case of an accident on a large and complex building, an intelligent and effective emergency evacuation system is required to ensure the safety of evacuees. Therefore, several studies have been performed on intelligent path finding and emergency evacuation algorithms which are centralized guidance methods using gathered data from distributed sensor nodes. However, another important aspect is effective rescue guidance in an emergency situation. So far, there has been no consideration on the efficient rescue guidance scheme. Therefore, this paper proposes the genetic algorithm based emergency rescue guidance method using distributed wireless sensor networks. Performance evaluation using a computer simulation shows that the proposed scheme guarantees efficient path finding. The fitness converges to the minimum value in reasonable time. The density of each exit node is remarkably decreased as well.