• Title/Summary/Keyword: Electrical Accident

Search Result 519, Processing Time 0.037 seconds

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

A Study on the Detail Conception for An Advanced Electrical Safety System By Analyzing Electricity Accidents (전기재해 분석을 통한 전기안전시스템의 선진화를 위한 개념적 구상)

  • Park, Dong-Jun;Kim, Jung-Hoon;Park, -Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.627-628
    • /
    • 2007
  • Since Korea has more accident rate than advanced country, it causes very serious problems in national. In this paper electricity accidents of Korea are analyzed by using a new microscopic method, which is different from existing macroscopic methods. And enhanced methodologies for Korean safety system are designed conceptually by analyzing and comparing causes of electricity accidents with advanced countries based on how many accidents occur by case types and what specification these types have.

  • PDF

The Analysis and Formation of Conductivity Path at Surface of Phenolic Resin (페놀수지 표면의 탄화도전로 생성과 분석)

  • Roh, Young-Su;Park, Sang-Taek;Kim, Jun-Won;Shong, Kil-Mok
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.102-103
    • /
    • 2007
  • Recently, the dependence of the electric energy is increased in accordance with a growth of industry. Therefore, scientific investigation is needed for the security of electrical safety and the judgement of accident causes. Accordingly, this paper consist of the analysis for the carbonization patterns of phenolic resin and the mechanism. As the follows, spider-legs as a carbide are generated around the rods, when the electric current flows on the surface of phenolic resin. The IR absorption peak generated by the thermal effects is appeared at about $1720cm^{-1}$. As the case of Joule's heat, the crystal of a carbide is generated beca use of the rarefied oxygen. It's estimated that the formation of carbonization conductivity as the currents are easily flowed.

  • PDF

On-site Survey of the Street Lighting Facilities (가로등의 전기설비 현장실태조사)

  • Kim, Han-Sang;Bae, Suk-Myong;Kim, Chong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.426-431
    • /
    • 2006
  • The case where a drain cannot flow backwards, a sewer institution can be unmanageable in this, and a mad is under water momentarily by local heavy nin by the climate phenomenon in spite of not being a lowlands belt has occurred well more than recently. By the flooded mea since it is in the state which has some human bodies at hand, when a short circuit occurs in street lighting pole which is the electric institution thing of a road, the danger of an electric shock accident becomes higher. In this paper, it was going to show improvement plan for grasping the brittle factor of street lighting pole electricity facilities through the on-site survey of street lighting pole electricity facilities, and improving this.

  • PDF

A Study of Lighting Environment to Improve the Visibility of Crosswalk in Rural Highway (지방부도로 횡단보도의 시인성 향상을 위한 조명환경에 관한 연구)

  • Lee, Mi-Ae;Lee, Suck-Ki;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.26-35
    • /
    • 2013
  • According to traffic accidents-related statistics, 57.6 percent of the fatality of vehicle-to-pedestrian accident, occurred on crosswalk in rural highways. Ministry of Land, Transport and Maritime Affairs in South Korea is conceiving to reduce in the number of the fatality. This study is to reestablish the criteria of implementing lighting through field experiments and to develop an effective alternative of crosswalk lighting.

DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE (지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치)

  • Bae, Jeong-Hyo;Ha, Yun-Cheol;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

Recovery time after quench of Au/YBCO thin film for fault accident detection (단락 사고 검출용 고온초전도체의 초전도성 회복 시간 변화 측정)

  • Yim, Seong-Woo;Kim, Hye-Rim;Hyun, Ok-Bae;Sung, Tae-Hyun;Sim, Jung-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.246-247
    • /
    • 2007
  • 최근 KEPRI-LSIS가 공동 개발한 하이브리드형 초전도 한류기 동작 시, 사고 검출을 담당하는 초전도체의 최적 설계에 적용하기 위하여 Au/YBCO 박막의 ��치 회복 특성을 조사하였다. $600\;V_{rms}$, 3 ms의 사고가 초전도 박막에 인가되었을 때, ��치가 종료된 이후 초전도성을 회복하기 위해 142 ms의 시간이 소요되었다. 또한 인가 시간이 증가함에 따라 소요 시간도 비례하여 증가하여 4 ms 동안 인가되었을 때, ��치 회복 시간은 272 ms로 측정되었다.

  • PDF

Protection Coordination Strategy of Microgrid Demonstration Site (마이크로그리드 실증사이트의 보호협조 전략)

  • Jin, Dae-Geun;Choi, Won-Jun;Won, Dong-Jun;Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.966-973
    • /
    • 2012
  • In microgrid demonstration site, distributed generations can make bidirectional power flows on the system. If an accident occurs, the fault current from the inverter based distributed generation is small. However, the conventional protection scheme in distribution network is designed to operate at high fault current. This means that the traditional protection of distribution network is no longer applicable and new protection methods must be developed. In this paper, for two cases, algorithms for protection coordination of demonstration site is proposed and verified through PSCAD/EMTDC simulation. In first case, protection devices are assumed to have the abilities of directional relaying and communication. In second case, protection devices do not have those abilities. Proposed protection coordination algorithms detect the fault locations and protect the microgrid fairly well.

Development of the Remote Monitoring System for Leakage Current Using Wireless Communication (무선통신을 이용한 누설전류 원격 감시시스템의 개발)

  • Park, Sung-Won;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.349-355
    • /
    • 2008
  • In this paper, a wireless remote monitoring system for leakage current of distribution board is developed. In the developed system, signals of the leakage current of distribution board are transmitted to a monitoring system using wireless communication. The developed system is consisted of a comparative module, control module, a wireless communication module, and hand held terminal. The developed system has any facilities which can check a leakage current with real time, send to the user this fact using a wireless remote interface method. And also developed system can take precaution for an accident by leakage current.

The Study on Aged Sleeves for Old Transmission Lines (노후 송전선로의 가공송전선 직선 슬리브 분석 연구)

  • Kim, Byung-Geol;Kim, Shang-Shu;Ahn, Sang-Hyun;Sohn, Hong-Kwan;Park, In-Pyo;Jang, Tae-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.538-540
    • /
    • 2007
  • A detailed study on aged sleeves for old transmission lines was carried out to clarify the deterioration of sleeves and the condition of installation. A lot of removed aged sleeves from transmission lines were investigated. Many biased installed cases and corrosion of steel sleeve part were found. These defects can cause a serious accident such as blackout during operating. The detailed results were presented in the text.

  • PDF