• Title/Summary/Keyword: Electric-Field Strength Measurement

Search Result 46, Processing Time 0.032 seconds

Reliability Improvement of Titania Ceramics with Surface Flaw Through High Voltage Screening

  • Tanaka, Tomohiro;Kishimoto, Akira
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.386-389
    • /
    • 1999
  • Effect of high voltage screening was examined on mechanical strength of titania ceramics with two different surface roughness. Roughly finished sample showed degraded mechanical strength meaning that the introduced flaw played the role of starting point of mechanical fracture. On such sample, electrically weak parts were eliminated by applying a screening field. Mechanical strength measurement on survived parts revealed that after screening the Weibull plots bended to become a convex curve while plots at high strength region were almost the same. This result means that relatively low mechanical strength parts were eliminated by the electrical method. As a result the Weibull modulus calculated from all the data increased, demonstrating the effect of high voltage screening on titania ceramics containing fracture controlling surface flaws. Roles of the surface flaw such as a common weak spot for both failures are disscussed in relation to the electric field concentration similar to that of mechanical stress.

  • PDF

Characteristic for the Near Field of Rectangle Loop Antenna using Optical Electric-Field Sensor (광전계 센서를 이용한 구형 Loop Antenna의 근접전계 특성)

  • 이주현;도쿠다마사미추;하덕호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.3
    • /
    • pp.217-225
    • /
    • 2003
  • In this paper, in order to investigate the near field distribution characteristic of the Loop Antenna we simulated and measured the near field of a Loop Antenna using optical electric-field sensor in a large Chamber(8.5 m x 7 m x 7 m). The simulation methods were used MoM for frequency domain and FDTD for time domain. From the analysis results, it can be seen that the simulation and measurement results are very aggregated, and the optical electric-field sensor is a certificate of validity. In frequency domain, in case of the optical sensor with vertical polarization is located above the near vertical line of the Loop Antenna the signal strength level is more 15 ㏈ than with horizontal polarization. But in case of the optical sensor located above horizontal line of the Loop Antenna, signal strength level is not different. And, in the time domain, although input signal is positive, in the case of the optical sensor with vertical polarization is located above horizontal line of the Loop Antenna, it can be seen that the received pulse shape is negative.

Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines (초고압 송전선로의 자계크기 해석과 실측 비교)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

The Study on Microstructures and Mechanical Properties of Mild Steel Joined with Various Spot Welding Conditions (점용접 조건에 의한 연강의 미세조직 및 기계적특성에 관한 연구)

  • 강연철;김대영;김완기;김석원
    • Journal of Welding and Joining
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2000
  • Spot welding, namely a kind of electric resisting welding has been used widely in field of automobile and aircraft industries because of easiness to apply. Specimens used in this study was a mild steel of 1.2mm thickness and the electrode was a Cu-Cr alloy of 6mm diameter. The surface sheared of specimens after testing of tensile shear was observed by SEM(scanning electron microscope) after ultrasonic cleaning for 10min., and microstructures and grain size of all specimens were measured with using of O.M.(Optical microscope). By the means of measurement and observations of tensile shear load, fatigue strength and share surface, the weldability of spot welding was evaluated. When tensile shearing testing, fracture starting point in all specimens was took place at the bond between HAZ(Heat affected zone) and nugget. With increasing in number of layers, fatigue strength was decreased. With increasing in electric current, grain size in the HAZ became more fine.

  • PDF

The Characteristics of Electric Field Distributions in a Reverberation Chamber using Cylindrical Diffuser (원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포특성)

  • Lee, Yong;Rhee, Joong-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.121-127
    • /
    • 2008
  • This paper presents an electric field distribution in a reverberation chamber using cylindrical diffuser. The characteristics of electric field distributions are compared with QRD(Quadratic Residue Diffuser) and cylindrical diffuser for $1{\sim}3$ GHz frequency band. The FDTD(Finite-Difference Time-Domain) method is used to analyze the field characteristics, and the field uniformity. At 2 GHz, the standard deviation and the tolerance of test volume in the reverberation chamber are improved by 0.11 dB, 0.43 dB for the case of cylindrical diffuser. The field strength is increased by 43.2 dBmV/m vs QRD's of 36.6 dBmV/m. Comparing with QRD's, the characteristic of polarization is also improved. These results show that reverberation chamber using cylindrical diffuser can be used alternative facility for measurement of electromagnetic interference and immunity.

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (대지전장측정에 의한 뇌경보시스템 개발에 관한 연구)

  • Kil, Gyung-Suk;Lee, Sung-Keun;Song, Jae-Yong;Kim, Jum-Sik;Kwon, Jang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.250-258
    • /
    • 2001
  • In this study, a lightning warning system (LWS) which can predict a lightning return stroke is developed, and the LWS is based on the measurement of electric field intensity at the ground level. The LWS consist of a rotation-type field mill as an electric field sensor, an impedance changer, a two-stage amplifier, and a microprocessor unit. From the calibration experiment, the frequency bandwidth and the maximum resolution of the LWS are $DC{\sim}200\;[Hz]$ and 73 [V/m], respectively. Also, the LWS can measure the electric field strength caused by a thunderstorm up to 18.7 [kV/m] at the ground. To ensure the sensing ability of the developed LWS in an actual situation, computer simulation using thundercloud models was carried out, and the result showed that the LWS can monitor the movement of thunderclouds within 6 [km] from the observation site.

  • PDF

Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower (345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.14-21
    • /
    • 1998
  • In this paper, the measurements of ELF electric and magnetic fields due to double circuit 345[kV} transmission lines are made using planar-type electric field sensor and multitum loop-type magnetic field sensor, and the magnitudes of electric and magnetic fields are illustrated by a three-dimensional plot. Also, in order to predict the magnetic field strength with lad variation, a typical daily load current curves of the transmission lines are displayed because the magnetic field is changed with load current. experimental results of ELF electric and magnetic fields along center line versus lateral distance are compared with the theoretical values computed by using the FIELDS program. The electric field intensity in and around a transmission tower is lowered, and the greatest point of the magnetic field is shifted to the heavy load line but generally is given the trend that the peak value appear at the central part of the transmission tower. The magnitudes of the maximum electric and magnetic fields in the vicinity of a transmission tower are less than 3.5[kV/m] and $20[{\mu}T]$, respectively. The measured electric and magnetic fields are satisfied with limits and guidelines recommended by various authorized international institutes.

  • PDF

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Electrical Conduction Mechanism of (Ba, Sr) $TiO_3$ Thin Film Capacitor in Low Electric Field Region (고유전 (Ba, Sr) $TiO_3$ 박막 커패시터의 저전계 영역에서의 전기전도기구)

  • Jang, Hoon;Jang, Byung-Tak;Cha, Seon-Yong;Lee, Hee-Chul
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.44-51
    • /
    • 1999
  • The electrical conduction mechanism of high dielectric $(Ba,Sr)TiO_3$ (BST) thin film capacitor, which is the promising cell capacitor for high density DRAM, was investigated in low field region (<0.2MV/cm). It is known that the current in the low field region consists of dielectric relaxation current and leakage current. The current-time (I-t) measurement technique under the constant voltage was used for extracting successfully each current component. The conduction mechanism of the BST capacitor was deduced from the dependency of the current on the measurement temperature, strength of electric field, the polarity of applied electric field and post annealing process. From these results, it was suggested that the dielectric relaxation current and the leakage current are originated from the redistribution of internally trapped electron by hopping process and Pool-Frenkel conduction mechanism, respectively. It was also concluded that traps causing these two current components are due to oxygen vacancies within the BST film.

  • PDF

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.